A. Copier
Code
E001
E000
E002
E003
Detail
0001
0002
0003
Cause
The fixing temperature does not increase.
•
The main thermistor (TH1) has poor
contact or an open circuit.
•
The fixing heater has an open circuit.
•
The thermal switch has an open circuit.
•
The DC controller PCB has a fault.
•
The image processor PCB has fault.
The fixing temperature has increased
abnormally.
•
The main thermistor (TH1) has a short
circuit.
•
The fixing heater drive circuit has a fault.
•
The DC controller PCB has a fault.
•
The image processor PCB has a fault.
The sub thermistor has detected
overheating.
•
The main thermistor (TH) has a short
circuit.
•
The fixing heater drive circuit has a fault.
•
The DC controller PCB has a fault.
•
The image processor PCB has a fault.
The sub thermistor has an open circuit.
•
The sub thermistor has an open circuit.
•
The SSR has a fault.
•
The DC controller PCB has a fault.
•
The image processor PCB has a fault.
The fixing temperature does not reach a
specific value.
•
The thermistor (TH1, TH2) is not
mounted properly, has poor contact, or
has an open circuit.
•
The fixing heater has an open circuit
or has a crack.
•
The fixing heater drive circuit has a fault.
•
The DC controller PCB has a fault.
•
The image processor PCB has a fault.
The fixing temperature has dropped
abnormally.
•
The thermistor (TH1, TH2) is not
mounted properly, has poor contact, or
has an open circuit.
•
The fixing heater has an open circuit
or has a crack.
•
The fixing heater drive circuit has a fault.
•
The DC controller PCB has a fault.
•
The image processor PCB has a fault.
Description
The main thermistor reading
does not reach 55°C 45 sec
after the main power switch has
been turned on.
The output of the main
thermistor has exceeded 220°C.
The output of the sub
thermistor has exceeded 235°C.
The output of the main thermistor
satisfies the following:
•
31 sec or more between
40°C and 75°C.
•
23 sec or more between
75°C and 100°C
•
19 sec or more between
100°C and 120°C
•
19 sec or more between
120°C and 140°C
•
19 sec or more between
140°C and 160°C.
•
15 sec or more between
160°C and 170°C.
•
The thermistor (TH1,
TH2) has detected 100°C or
less after wait-up.
Summary of Contents for GP405
Page 16: ......
Page 44: ......
Page 66: ......
Page 84: ......
Page 86: ......
Page 112: ......
Page 114: ......
Page 126: ......
Page 128: ......
Page 162: ......
Page 232: ......
Page 234: ......
Page 276: ......
Page 306: ......
Page 308: ......
Page 344: ......
Page 358: ......
Page 408: ......
Page 410: ......
Page 418: ......
Page 453: ...COPYRIGHT 1999 CANON INC CANON 405 335 REV 0 JAN 1999 PRINTED IN JAPAN IMPRIME AU JAPON 14 35 ...
Page 454: ......
Page 662: ......
Page 676: ...A 14 COPYRIGHT 1999 CANON INC CANON 405 335 REV 0 JAN 1999 PRINTED IN JAPAN IMPRIME AU JAPON ...
Page 680: ......