CHAPTER 14 TROUBLESHOOTING
3
Mounting the Scanning Lamp
Keep the following in mind when
mounting the scanning lamp:
1.
Orient it so that the side (terminal) with
the manufacturer's name is toward the
rear.
2.
Orient it so that its transparent side is
toward the reflecting plate.
3.
Do not touch the transparent side.
Figure 14-213
Make the following adjustments when
replacing the scanning lamp:
1) Shading correction 2
FUNCTION>CCD>MAN-ADJ
2) Auto density correction
FUNCTION>DENS> WHITE-ME
PD-DENS
PD-ME
DZ-DENS
DZ-ME
For details, see the description for
FUCNTION in service mode (VIII. of Chapter
14).
Transparent side
Reflecting plate
C. Image Formation System
1
When Replacing the Drum Unit
•
Record the date and the counter reading
on the label, and attach it to the front cover
of the new drum unit.
•
Clean the fixing separation claw (upper,
lower).
date
date Datum
notes
note Notiz
counter
compteur Zähler
Summary of Contents for GP405
Page 16: ......
Page 44: ......
Page 66: ......
Page 84: ......
Page 86: ......
Page 112: ......
Page 114: ......
Page 126: ......
Page 128: ......
Page 162: ......
Page 232: ......
Page 234: ......
Page 276: ......
Page 306: ......
Page 308: ......
Page 344: ......
Page 358: ......
Page 408: ......
Page 410: ......
Page 418: ......
Page 453: ...COPYRIGHT 1999 CANON INC CANON 405 335 REV 0 JAN 1999 PRINTED IN JAPAN IMPRIME AU JAPON 14 35 ...
Page 454: ......
Page 662: ......
Page 676: ...A 14 COPYRIGHT 1999 CANON INC CANON 405 335 REV 0 JAN 1999 PRINTED IN JAPAN IMPRIME AU JAPON ...
Page 680: ......