3-34
COPYRIGHT © CANON ELECTRONICS INC. 2008
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
4) Remove 2 screws
{
1
(M3, TP head,
self-tapping) and turn the reading PCB
{
2
over.
Note:
Do not pull it excessively because the
cables are connected to it.
Figure 3-508
5) Pull out both ends of the lock plate of the
connector
{
1
using the clips
{
2
and re-
move the flat cable
{
3
. In the same way,
remove the flat cable on the opposite side.
Figure 3-509
Notes on assembling
When the lock plate of the connector is
open, insert the flat cable into the con-
nector until the contact surface of the flat
cable is entirely covered and then close
the lock plate.
When assembling the PCB in the case,
align the end surface of the PCB with the
end surface of the sponge of the case and
press it. The PCB must not ride on the
sponge.