3-24
COPYRIGHT © CANON ELECTRONICS INC. 2008
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
IV. BASE UNIT-2 (FEED SYSTEM)
1. Entrance Lower Guide Unit
1) Remove the retard roller.
2) Remove screw
{
1
(M3, round tips), and
while unhooking 2 pairs of the fitting parts
{
2
, remove the cover
{
3
. In the same way,
remove the cover on the opposite side.
Note:
A light guide for the sensor is built in the
right cover.
Figure 3-401
3) Remove 3 screws
{
1
(short stepped) and
remove the entrance lower guide unit
{
2
.
Figure 3-402
2. Platen Roller (Lower)
1) Remove 2 screws
{
1
(M3, round tip) us-
ing a short screwdriver, lift the front of the
guide plate
{
2
, and while unhooking 2
pairs of the rear fitting parts
{
3
, remove
the guide plate.
Note:
If no short screwdriver is available,
remove the upper unit.
Figure 3-403
2) Lower the front of the platen roller
{
1
, turn
it, align the positions of both bearings
{
2
and pull it out upward.
Figure 3-404
Notes on assembling
Insert the fitting parts of the guide plate
below the fitting parts of the platen roller.