COPYRIGHT © CANON ELECTRONICS INC. 2008 CANON DR-X10C FIRST EDITION
3-61
CHAPTER 3 DISASSEMBLY & REASSEMBLY
4. Reading Holder
Note:
A reading glass and a shading sheet are
mounted in this reading holder. If it is
removed, the CIS unit is exposed.
1) Open the upper unit.
2) Slide the reading holder to the right and
remove it while pushing down the fitting
parts
{
2
on the lower right side of the
reading holder
{
1
with a tool with a thin
tip.
Figure 3-909
Note:
Other parts
Differences between flat cables
The differences between the flat cables
(FFC) of the reading unit (upper) and the
reading unit (lower) are shown below.
The contact surface of the flat cable for the
reading unit (upper) is in the reverse di-
rection and the one of the flat cable for the
reading unit (lower) is in the same direction.
The flat cable for the upper unit is longer
than the one for the lower unit.
Flat cable (upper)
Flat cable (lower)
Contact surface
Figure 3-910
For disassembly and assembly of reading unit
components, refer to “V. BASE UNIT-3
(READING SYSTEM)”.