7-128
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
39
The lifter fails to move up (pick-up from the cassette).
Cause
Cassette
Latch (cassette)
Spring, Lever
Lifter position
sensor
Cassette 1 lifter
motor (M16),
Cassette 2 lifter
motor (M17)
DC controller
PCB
Step
1
2
3
4
5
Checks
Slide out the cassette, and lift the
holding plate inside the cassette.
Does it move smoothly?
Is the movement of the latch
assemblyof the cassette grip nor-
mal?
Push up the pick-up roller releasing
lever by a finger. Does the pick-up
roller move down?
Is the lifter position sensor normal?
Set the tester to the 30VDC range,
and insert the cassette. Does the
voltage between the following
terminals change from about 0 V to
about 24 V?
M16: J2222A-7 (+), 6
M17: J2222A-11 (+), 6
Yes/No
NO
NO
NO
NO
YES
NO
Action
Check the inside of the
cassette for foreign
matter.
Re-install it.
Remove the pick-up
assembly, and check the
spring and lever.
Check the lever and
wiring; if normal, replace
the sensor.
Check the wiring from the
connector to the motor; if
normal, replace the motor.
Replace the DC controller
PCB.
Summary of Contents for 1000S
Page 12: ......
Page 30: ......
Page 44: ......
Page 86: ......
Page 254: ......
Page 372: ......
Page 374: ......
Page 418: ......
Page 438: ......
Page 442: ......
Page 754: ......
Page 764: ......
Page 766: ......
Page 840: ...0501GR PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 100 reprocessed paper ...