4. MECHANICAL SYSTEM
4-76
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
4. Removing the Toner Level Sensor
1)
Remove the hopper left/right cover, and
remove the two fixing screws [1] of the hopper
assembly.
4)
Remove the toner level sensor.
In the case of a color toner hopper [4],
disconnect the connector [5], and remove the
two screws [6]. (sub toner level sensor)
Figure 4-717A
2)
Hold the left and right grips, and lift the hopper
assembly while pulling it to the front.
3)
Remove the four screws [2], and remove the
hopper lower front cover [3].
Figure 4-718A
Figure 4-719A
In the case of the main toner level sensor [7],
remove the hopper; then, disconnect the
connector, and remove the two screws [8].
Figure 4-720A
[1]
[5]
[6]
[4]
[2]
[2]
[3]
[7]
[8]
Summary of Contents for 1000S