9.2
LoggerNet
network map configuration
Once a serial or telemetry link between
LoggerNet
and the base station is physically established,
LoggerNet
needs to be configured to enable communications to occur through the base station
and outward to the remote CRVW3 stations. The Setup Screen
in
LoggerNet
is used to create a
tree-list of CRVW3 stations and their connectivity settings, as well as details for related hardware.
This list of devices shows in multiple locations throughout the software and is called the network
map.
NOTE:
If
Network
Planner
was
used
to
configure
your
network
of
CRVW3
devices,
you
can
use
a
function
in
that
software
to
configure
the
network
map
of
LoggerNet
so
that
it
can
communicate
with
the
base
station
and
the
CRVW3
devices.
Note
the
checkbox
for
configuring
LoggerNet
located
in
the
Configure
Devices
checklist
on
the
main
screen.
Once
that
task
is
executed,
you
will
see
the
results
of
this
configuration
show
up
automatically
in
the
Setup
Screen
of
LoggerNet
.
This
enables
you
to
bypass
the
manual
steps
shown
in
this
section.
Refer
to:
/documents/us/manuals/loggernet.pdf
.
1. From the Main category of the
LoggerNet
toolbar click Setup
.
2. If the Setup Screen comes up in the
EZSetup
mode, click the Std View button to put it into
the standard view mode.
3. Click Add Root. When using a USB or serial cable connection to the base station, select
ComPort for the type of root device. If you have a telemetry connection between
LoggerNet
and the base station, you will usually choose IPPort as the root device.
CRVW3 3-Channel Vibrating-Wire Data Logger