7. Set the following settings:
Table 7-2: Base radio settings
Name
Setting
Active Interface
USB
Radio Operation Mode Gateway
Repeaters Used
Leave checkbox cleared
Network ID
Value should match the CRVW3 ID exactly (0 to 4095)
Frequency Key
Leave at 5
Transmit Power
Leave at 10
Receive SubNet ID
Leave at 15
Transmit SubNet ID
Leave at 15
Radio ID
Must be unique for each radio device; use 1 (CRVW3 will use 0)
8. Click Apply.
9. Leave the USB cable connected to the USB port of the RF451/RF452 and the computer.
Deployment, Settings Editor, and Send OS tabs are available. The Deployment tab contains all
the standard parameters that need to be set for a PakBus® network. The Settings Editor tab may
be used to access all of the FreeWave® Radio settings. It should be used by experienced
FreeWave Radio users only. New operating systems for the Campbell Scientific board are loaded
through the Send OS tab.
Device Configuration Utility
makes applying the same settings to multiple devices easy. Once
settings are configured for one device, click Apply to save your changes; a summary screen
similar to
(p. 31) will be shown. Click Save to save a configuration file. This file can then
be used to load the settings into another radio. Click Read File to load the settings in
Device
Configuration Utility
. Then click Apply to save your changes to load the settings into the radio.
CRVW3 3-Channel Vibrating-Wire Data Logger
30