Using
Device Configuration Utility
, confirm the following settings:
l
Station Name
l
Measurement interval
l
PakBus Address
l
Is Router (should be set to True when CRVW3 is also a radio repeater)
l
Radio settings
Refer to
(p. 21) if any settings need to be adjusted. If you previously
saved the configuration summary through
Device Configuration Utility
, you can restore them by
clicking Read File then Apply.
8.8.1 Confirm CRVW3 sensor measurements
Use
Device Configuration Utility
to validate CRVW3 measurements.
1. Connect to the CRVW3 (see
(p. 20) for more information).
2. Use the Troubleshoot tab screen to test the sensor response for each channel. The
diagnostic information provided helps to determine whether the connected sensor is
operating correctly.
3. Click Poll to perform the test. The results will appear after a few seconds.
4. Use the Channel selection box to select each active channel in turn for individual testing.
CRVW3 3-Channel Vibrating-Wire Data Logger