Section 8. Operation
522
HTTPOut
("<p>Temperature: " + Tempe "</p>")
HTTPOut
("<p><h2> Links:</h2></p>")
HTTPOut
("<p><a href="+
CHR
(34) +"monitor.html"+
CHR
(34)+">Monitor</a></p>")
HTTPOut
("</body>")
HTTPOut
("</html>")
WebPageEnd
'Monitor Web Page
WebPageBegin
("monitor.html",Commands)
HTTPOut
("<html>")
HTTPOut
("<style>body {background-color: oldlace}</style>")
HTTPOut
("<body>")
HTTPOut
("<title>Monitor CR6 Datalogger Tables</title>")
HTTPOut
("<p><h2>CR6 Data Table Links</h2></p>")
HTTPOut
("<p><a href="+
CHR
(34) + "command=TableDisplay&table=CRTemp&records=10" + _
CHR
(34)+">Display Last 10 Records from DataTable CR1Temp</a></p>")
HTTPOut
("<p><a href="+
CHR
(34) + "command=NewestRecord&table=CRTemp"+
CHR
(34) + _
">Current Record from CRTemp Table</a></p>")
HTTPOut
("<p><a href="+
CHR
(34) + "command=NewestRecord&table=Public"+
CHR
(34) + _
">Current Record from Public Table</a></p>")
HTTPOut
("<p><a href="+
CHR
(34) + "command=NewestRecord&table=Status" +
CHR
(34) + _
">Current Record from Status Table</a></p>")
HTTPOut
("<br><p><a href="+
CHR
(34) +"default.html"+
CHR
(34) + ">Back to the Home Page _
</a></p>")
HTTPOut
("</body>")
HTTPOut
("</html>")
WebPageEnd
BeginProg
Scan
(1,Sec,3,0)
PanelTemp
(RefTemp,250)
RealTime
(Time())
Minutes =
FormatFloat
(Time(5),"%02.0f")
Seconds =
FormatFloat
(Time(6),"%02.0f")
Temperature =
FormatFloat
(RefTemp, "%02.02f")
CallTable
(CRTemp)
NextScan
EndProg
8.10.1.7 HTTPS
The CR6 has the ability to act as a HTTPS server.
1. In
Device Configuration Utility
(always use the latest version) click on the
Networks Services Tab
and check the
HTTPS
box.
2. Next, click on the
TLS
tab. From here you can set:
a. The
TLS Server Connections
(increment the numerical
Max TLS Server
Connections
dialog box by entering in a number or using the up / down arrow
keys).
b. The TLS private key (click on
Set Private Key
). c. Load certificate (click on
Set Certificate
).
3. Click
Apply
at bottom of screen to save the settings.
Summary of Contents for CR6 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Page 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Page 136: ......
Page 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Page 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Page 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Page 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Page 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Page 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Page 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Page 546: ......
Page 552: ......
Page 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Page 612: ......
Page 648: ......
Page 650: ......
Page 688: ......
Page 689: ......