background image

5

Zero output from receptacles

Low output voltage 

6 Vac or above

with no load

Below 6 Vac

High output voltage with no load

Low output voltage under load

Erratic output voltage

Noisy operation

Engine won’t start

1. Engine speed is too slow
2. Open or shorted wiring

3. Faulty capacitor
4. Open/shorted rotor or stator windings

5. Open rectifier

1. Engine speed is too slow
2. Open rectifier
3. Faulty capacitor
4. Open/shorted rotor or stator windings

1. Generator head not magnetized

1. Faulty capacitor
2. Engine speed is too fast

1. Open rectifier
2. Engine speed too slow at full load
3. Excessive load applied

1. Dirty, corroded, or loose wiring

connection

2. Unbalanced load applied

1. Loose generator or engine bolt
2. Short circuit in generator field or load

3. Faulty bearing

1. No fuel.
2. Fuel switch is in closed position.
3. Engine switch is in closed position.
4. Spark plug dirty or wrong gap

5. Not enough compression inside the

cylinder

1. Adjust engine speed 

2. Clean and reconnect all wiring 

3. Replace capacitor 

4. Test winding resistance, replace winding

if necessary 

5. Test rectifier, replace if necessary 

1. Adjust engine speed 

2. Test rectifier, replace if necessary 

3. Replace capacitor 

4. Test winding resistance, replace winding

if necessary 

1. Re-magnetize generator head 

1. Replace capacitor 

2. Adjust engine speed 

1. Test rectifier, replace if necessary 

2. Adjust engine speed 

3. Reduce the applied load

1. Referring to the wiring diagram, clean

and reconnect all wiring 

2. Remove all loads, then apply each one

individually to determine which one is
causing erratic function

1. Tighten all mountings
2. Test winding resistance, replace field

winding if necessary

Test load devices for shorts. Replace
defective load device.

3. Replace bearing

1. Check fuel. 
2. Place fuel switch in open position.
3. Place engine switch in open position.
4. Clean spark plug. Adjust gap. (See page 3)

Replace if necessary.

5. Check leakage from the cylinder

These diagnostic and repair procedures should be performed by an authorized service center.

Troubleshooting Chart

  Symptom                                                              Possible Cause(s)                                                     Corrective Action

Model GN1200 

 Model

GN 1200

GENERATOR

Type

Single-Phase, Brushless

Voltage

120 V

Frequency

60 Hz

Maximum Output

1500 W

Rated Out put

1100 W

ENGINE

Type

1-cylinder, 4-stroke, forced air cooling gasoline engine

Displacement

87 cc

Maximum Output

3.0 HP/ 4000 rpm

Fuel

Unleaded Gasoline

UNIT

Oil Capacity

400 ml

Fuel tank capacity

5.5 L

Dimensions (L x W x H)

430 x 310 x 370 mm

Noise Level @ 7 m

68 dB (A)

Net Weight

25 kg

Specifications

Summary of Contents for GN1200

Page 1: ...structions can cause equipment damage and or serious personal injury Retain all manuals for future reference 2 Never use this generator for any application other than that specified by the manufacture...

Page 2: ...ued Operation The generator is shipped from the factory without oil in the engine crankcase Engine oil is a major factor affecting engine perfor mance and service life Non detergent oils and vegetable...

Page 3: ...switch to the closed horizontal position CAUTION 5 Verify that the generator has com pletely stopped 6 Allow unit to cool before placing in storage LOAD DEVICES 1 The 120 volt receptacles type NEMA 5...

Page 4: ...ilter and disassemble Wash filter in a solvent Dry with a clean cloth Reinstall in generator Maintenance Continued Wiring Diagram Guide 1 Rotor Rectifier 2 Rotor Assembly 3 Starter Assembly 4 AC coil...

Page 5: ...f necessary 3 Replace capacitor 4 Test winding resistance replace winding if necessary 1 Re magnetize generator head 1 Replace capacitor 2 Adjust engine speed 1 Test rectifier replace if necessary 2 A...

Page 6: ...apply to you C Any failure that results from an accident shipping damage purchaser s abuse neglect or failure to operate products in accordance with instructions provided in the owner s manual s supp...

Page 7: ...ricante 3 Para manuten o e reparos use somente produtos e pe as recomendados pelo fabricante 4 Certifique se de que o gerador esteja adequadamente aterrado em um fio terra externo antes da opera o MAN...

Page 8: ...de preocupa o significa apenas que o motor est funcionando de maneira eficaz 2 Verifique o n vel do leo no c rter do motor antes de dar partida O n vel do leo deve estar entre as marcas dos n veis sup...

Page 9: ...ar o n vel do leo insira lentamente a vareta medidora de n vel at tocar o fundo Troque o leo ap s as primeiras oito 8 horas de opera o A seguir troque o leo a cada cinq enta 50 horas de opera o ou a c...

Page 10: ...do diagrama da fia o el trica 1 Retificador do rotor 2 Conjunto do rotor 3 Conjunto do acionador de partida 4 Bobina de CA 5 Bobina de excita o 6 Bobina de CC 7 Conector 8 Protetor de CA 9 Medidor de...

Page 11: ...ste a resist ncia do enrolamento substitua se necess rio 1 Re magnetize o cabe ote do gerador 1 Substitua o capacitor 2 Ajuste a velocidade do motor 1 Teste o retificador substitua se necess rio 2 Aju...

Page 12: ...essa abuso por parte do comprador neglig ncia ou da n o opera o do produto de acordo com as instru es no s manual ais do propriet rio que acompanha m este produto D Servi os de pr entrega isto montage...

Page 13: ...Notas 13 PG Modelo GN1200...

Page 14: ...nte 3 Para mantener y reparar este generador use s lo los productos y partes recomendados por el fabricante 4 Aseg rese de que el generador est bien conectado con un cable externo de toma de tierra an...

Page 15: ...otor El nivel de aceite debe quedar entre las marcas superior e inferior del medidor del nivel de aceite Capacidad de aceite 0 4 L El generador se entrega de f brica sin aceite en la caja del cig e al...

Page 16: ...r al 75 Aseg rese de que el aceite permanezca al nivel adecuado Revise el nivel de aceite cada ocho 8 horas o a diario Cuando revise el nivel de aceite enrosque la varilla de medici n lentamente hasta...

Page 17: ...enerador Mantenimiento Continuaci n Modelo GN1200 Diagrama de cableado Esquema al mbrico para GN1200 Gu a del diagrama de cableado 1 Rectificador del rotor 2 Ensamble del rotor 3 Ensamble del arranque...

Page 18: ...or 2 Examine el rectificador reempl celo si es necesario 3 Reemplace el condensador 4 Mida la resistencia del arrollamiento reempl celo si es necesario 1 Remagnetice cabeza de generador 1 Reemplace el...

Page 19: ...ia o incidente al operar productos de acuerdo con las instrucciones proporcion en el manual es del propietario provisto el producto D Servicio de Pre salida es decir ensamblaje aceite o lubricantes y...

Page 20: ...Notes Notas Modelo GN1200 Manual de Instrucciones 20 Sp...