2

Operating Instructions

                              Do not operate

this generator on

wet surfaces or in the rain.

13. Never operate the generator with dam-

aged, broken or missing parts, or with
any guarding components removed.

                                Shut off the

generator engine

and disconnect the spark plug wire
before performing any service or
maintenance to the unit.

14. Do not refill the fuel tank while the

engine is running. Use precautions to
prevent fuel spillage during refills.
Be sure the fuel tank cap is securely
in place before starting the engine.
Allow engine to cool for at least
two minutes before refueling.

15. Be sure to store gasoline in clean

containers that do not contain
water, dirt or rust because this will
cause the engine to shut down. 

PRE-OPERATION

1. Check fuel every

time you start
your generator.
Always use clean
fuel – see #15
above.

We recommend that

you use unleaded fuel because it pro-
duces fewer engine and spark plug
deposits and extends the life of exhaust
system components. Use a lower octane
gasoline can cause persistent “pinging”
or heavy “spark knock”(a metallic rap-
ping noise) which, if severe, can lead to
engine damage. If “spark knock” or
“pinging” occurs at a steady engine
speed under normal load, change
brands of gasoline. Occasionally you
may experience light spark knock while
operating under heavy loads. This is no
cause for concern, it simply means your
engine is operating efficiently.

2. Check oil level in the crankcase of

engine before starting the engine.
The oil level should be positioned
between the lower and upper level
marks on the oil gauge.

Oil Capacity: 0.4 L

!

WARNING

!

CAUTION

!

DANGER

NEVER

OPERATE YOUR

GENERATOR UNDER THESE
CONDITIONS:

1. Rain or inclement weather

2. Excessive vibration

3. Sparking

4. Engine misfire

5. Electric output loss

6. Changing or fluctuating engine

speed

7. Overheating in connected

equipment

8. Damaged receptacles

9. Damaged, broken or missing

parts

10. Guarding components removed

ALWAYS

OPERATE YOUR

GENERATOR UNDER THESE
CONDITIONS:

1. Read and understand these

instructions

2. Clear of all persons

3. Properly grounded (generator)

4. Properly grounded

(tools, appliances, etc.)

5. Flat level surfaces

6. Well ventilated areas

General Safety

(Continued)

Operation

The generator is

shipped from the factory without oil in
the engine crankcase. Engine oil is a
major factor affecting engine perfor-
mance and service life. Non-detergent
oils and vegetable oils are not recom-
mended. Use premium quality 4-stroke
motor oil. Do not add commercial addi-
tives to the recommended oil and
do not mix gasoline with the oil. 
SAE 10W-30 is recommended for gener-
al, all-temperature use. Other viscosi-
ties shown in the chart may be used
when the average temperature in your
area is within the indicated range.

3. The plug of powered equipment can

only be connected to the AC output-
socket after the unit is running stably.

4. Use of a Ground Fault Circuit Inter-

rupter (GFCI) is strongly recommend-
ed. Ground Fault Circuit Interrupters
can significantly reduce the possibility
of injury if an electrical short occurs. 

                                A Ground Fault

Circuit Interrupter

may not be effective if used on a gen-
erator that is not grounded! 

5. When installing a GFCI, be sure to

follow all national and local regula-
tions, or call a licensed or certified
electrical technician. 

GROUNDING 

1. Use the ground

terminal on the
generator frame
to connect the
unit to a suit-
able ground

!

WARNING

!

CAUTION

source. Securely fasten the end ter-
minal of the ground wire to the
ground terminal on the generator
frame. 

2. The ground wire should be made of

#8 gauge wire. Do not use wire with
a higher gauge number. Higher
gauge numbers indicate thinner
wire, which may not provide an
adequate ground path.

3. The other end of the ground wire

must be securely fastened to an
approved ground source.

The following are ground sources
approved by the National Electric Code.
Other ground sources may be accept-
able. Refer to the National Electric Code
and local regulations for further
ground source information. If not sure
of regulations or procedures, obtain
assistance from a qualified (licensed or
certified) electrical technician.

a. An underground water pipe at

least ten feet in length.

b. A non-corrosive underground pipe

at least eight feet in length and
3/4 inch diameter.

c. A steel or iron underground rod at

least eight feet in length and
5/8 inch diameter.

d. A non-ferrous rod at least eight feet

in length, 1/2 inch in diameter, and
approved for grounding purposes.

Any rod or pipe used for grounding
must be driven to eight feet deep or
buried in the deepest possible trench.

Summary of Contents for GN1200

Page 1: ...structions can cause equipment damage and or serious personal injury Retain all manuals for future reference 2 Never use this generator for any application other than that specified by the manufacture...

Page 2: ...ued Operation The generator is shipped from the factory without oil in the engine crankcase Engine oil is a major factor affecting engine perfor mance and service life Non detergent oils and vegetable...

Page 3: ...switch to the closed horizontal position CAUTION 5 Verify that the generator has com pletely stopped 6 Allow unit to cool before placing in storage LOAD DEVICES 1 The 120 volt receptacles type NEMA 5...

Page 4: ...ilter and disassemble Wash filter in a solvent Dry with a clean cloth Reinstall in generator Maintenance Continued Wiring Diagram Guide 1 Rotor Rectifier 2 Rotor Assembly 3 Starter Assembly 4 AC coil...

Page 5: ...f necessary 3 Replace capacitor 4 Test winding resistance replace winding if necessary 1 Re magnetize generator head 1 Replace capacitor 2 Adjust engine speed 1 Test rectifier replace if necessary 2 A...

Page 6: ...apply to you C Any failure that results from an accident shipping damage purchaser s abuse neglect or failure to operate products in accordance with instructions provided in the owner s manual s supp...

Page 7: ...ricante 3 Para manuten o e reparos use somente produtos e pe as recomendados pelo fabricante 4 Certifique se de que o gerador esteja adequadamente aterrado em um fio terra externo antes da opera o MAN...

Page 8: ...de preocupa o significa apenas que o motor est funcionando de maneira eficaz 2 Verifique o n vel do leo no c rter do motor antes de dar partida O n vel do leo deve estar entre as marcas dos n veis sup...

Page 9: ...ar o n vel do leo insira lentamente a vareta medidora de n vel at tocar o fundo Troque o leo ap s as primeiras oito 8 horas de opera o A seguir troque o leo a cada cinq enta 50 horas de opera o ou a c...

Page 10: ...do diagrama da fia o el trica 1 Retificador do rotor 2 Conjunto do rotor 3 Conjunto do acionador de partida 4 Bobina de CA 5 Bobina de excita o 6 Bobina de CC 7 Conector 8 Protetor de CA 9 Medidor de...

Page 11: ...ste a resist ncia do enrolamento substitua se necess rio 1 Re magnetize o cabe ote do gerador 1 Substitua o capacitor 2 Ajuste a velocidade do motor 1 Teste o retificador substitua se necess rio 2 Aju...

Page 12: ...essa abuso por parte do comprador neglig ncia ou da n o opera o do produto de acordo com as instru es no s manual ais do propriet rio que acompanha m este produto D Servi os de pr entrega isto montage...

Page 13: ...Notas 13 PG Modelo GN1200...

Page 14: ...nte 3 Para mantener y reparar este generador use s lo los productos y partes recomendados por el fabricante 4 Aseg rese de que el generador est bien conectado con un cable externo de toma de tierra an...

Page 15: ...otor El nivel de aceite debe quedar entre las marcas superior e inferior del medidor del nivel de aceite Capacidad de aceite 0 4 L El generador se entrega de f brica sin aceite en la caja del cig e al...

Page 16: ...r al 75 Aseg rese de que el aceite permanezca al nivel adecuado Revise el nivel de aceite cada ocho 8 horas o a diario Cuando revise el nivel de aceite enrosque la varilla de medici n lentamente hasta...

Page 17: ...enerador Mantenimiento Continuaci n Modelo GN1200 Diagrama de cableado Esquema al mbrico para GN1200 Gu a del diagrama de cableado 1 Rectificador del rotor 2 Ensamble del rotor 3 Ensamble del arranque...

Page 18: ...or 2 Examine el rectificador reempl celo si es necesario 3 Reemplace el condensador 4 Mida la resistencia del arrollamiento reempl celo si es necesario 1 Remagnetice cabeza de generador 1 Reemplace el...

Page 19: ...ia o incidente al operar productos de acuerdo con las instrucciones proporcion en el manual es del propietario provisto el producto D Servicio de Pre salida es decir ensamblaje aceite o lubricantes y...

Page 20: ...Notes Notas Modelo GN1200 Manual de Instrucciones 20 Sp...

Reviews: