Page 1: ...e contact Global Industrial Customer Service at 1 800 645 2986 or visit www globalindustrial com with any questions or concerns Portable Gasoline Generator Model 716173 3300 Watts Model 716174 7000 Watts Danger Read Safety Information and Entire Manual Before Use ...

Page 2: ...L 8 ASSEMBLY 7 BATTERY INSTALLATION ADD GASOLINE 9 GROUNDING GENERATOR 9 OPERATION STARTING THE ENGINE STOPPING THE ENGINE USING THE GENERATOR 12 MAINTENANCE 13 SERVICING AIR FILTER 14 SERVICING SPARK PLUG 14 SERVICING MUFFLER SPARK ARRESTOR 15 DRAINING ENGINE OIL 15 STORAGE 16 TROUBLESHOOTING 17 10 10 11 12 ...

Page 3: ...ve on 3 Pull choke lever out to Start 4 Insert key into panel lock 5 Electric Start Turn starter switch to START once power starts turn back to ON 6 Manual Start Turn starter switch ON pull starting cord 7 Observe output display 8 Set air switch breaker ON plug in electrical devices 1 Set air switch breaker off unplug electrical devices 2 Wait 2 5 minutes for cool down 3 Turn starter switch off 4 ...

Page 4: ... operation that may be hazardous if performed incorrectly or carelessly Observe them carefully Their definitions are as follows DANGER indicates a hazard which if not avoided will result in death or serious injury WARNING indicates a hazard which if not avoided could result in death or serious injury CAUTION indicates a hazard which if not avoided could result in minor or moderate injury SAVE THIS...

Page 5: ... ALWAYS ground the generator before using it see the Ground the Generator Generator should only be plugged into electrical devices either directly or with an extension cord NEVER connect to a building s electrical system without a qualified electrician Such connections must comply with local electrical laws and codes Failure to comply can create a back feed which may result in serious injury or de...

Page 6: ...his may result in overheating or stressing of the components possibly leading to a generator failure WARNING If this generator is used as a supply for a building s wiring system the generator must be installed by a qualified electrician and connected to a transfer switch as a separately derived system in accordance with the National Electrical Code NFPA 70 The generator shall be connected to a tra...

Page 7: ...R 3 GFCI SOCKET 120V 20A 4 L14 20R 120V 240V 20A 5 ELECTROMAGNETIC CIRCUIT BREAKER 6 USB SOCKET 7 GROUNDING BOLT No ITEM NAME 1 STARTER SWITCH 2 VOLTMETER 3 ELECTROMAGNETIC CIRCUIT BREAKER 4 USB SOCKET 5 GROUNDING BOLT 6 L14 30R 120V 240V 30A 0 0 0 0 7 GFCI SOCKET 120V 20A 8 THERMAL OVERLOAD ...

Page 8: ...ours Handle Style Wheel Type Maintenance Kit Warranty Noise Ra ng Dimensions L x W x H Weight lbs AC Rated Output Running Wa s 3000W 3300W 120V 240V 60Hz 25A 12 5A 27A 13 5A 208CC UP170E 3600RPM 0 6L SAE 10W 30 0 16GAL 2kw On the Carburetor Recoil and and electric start Float break Yes Key On the control panel Yes 4 0GAL 14 9 Single handle Rubber wheel Yes Yes 96dB 24 x17 x18 inch 9 F6TC F6TC 5 6 ...

Page 9: ...racket G to frame with bolts H 2 Slide bolts I through handle bracket G and handle J L Install nut K Model 716173 3300 Watts Steps for assembly requirements Model 716174 7000 Watts NOTE The wheels are not intended for over the road use Install wheels as follows See Figure 2 1 1 Slide axle pin B through the wheel A wheel bracket on frame Insert cotter pin C Install frame foot as shown in Figure 2 1...

Page 10: ...nerator or shorten its lifespan Step 1 ADD OIL User must add the proper type and amount of oil before operating the generator Failure to do so could result in engine damage Place generator on a level surface Verify oil fill area is clean Remove oil fill cap and wipe dipstick clean Add recommended engine oil as shown in the below chart Thread dipstick into oil filler neck Oil level is checked with ...

Page 11: ...uring use even with the fuel cap in place Reinstall fuel cap and wipe clean any spilled gasoline with a dry cloth WARNING NEVER use an oil gasoline mixture NEVER use old gasoline Avoid getting dirt or water into the fuel tank Gasoline can age in the tank and make starting difficult Never store generator for extended periods of time with fuel in the tank or the carburetor Turn the fuel cock off and...

Page 12: ...er the generator has been running move to fresh air IMMEDIATELY See a doctor as you could have carbon monoxide poisoning WARNING This generator produces powerful voltage which can result in electrocution ALWAYS ground the generator before using it See the Ground the Generator portion of the Generator Preparation section of this manual for details WARNING Generator should only be plugged into elect...

Page 13: ...ect any electrical devices This allows the generator to stabilize its speed and temperature To start the generator with electric start perform the following steps Unplug all electrical devices from the generator during ignition Otherwise it will be difficult for the engine to start Check that the generator is properly grounded Check the oil and fuel levels Check the battery and make sure the wire ...

Page 14: ...to the home Even a properly connected portable generator can become overloaded This may result in overheating or stressing the machine s components possibly leading to a generator failure Before connecting electrical devices allow the generator to run for a few minutes to stabilize the speed and voltage output NOTE Do not operate store or transport the unit at an angle greater than 15 degrees KNOW...

Page 15: ...uipment damage Clean generator daily or before each use Keep area around and behind muffler free from combustible debris Inspect all cooling air openings on generator Use a damp cloth to wipe exterior surfaces clean Use a soft bristle brush to loosen caked on dirt oil etc Use a vacuum to pick up loose dirt and debris Low pressure air not to exceed 25 PSI may be used to blow away dirt Inspect cooli...

Page 16: ...r cover before reinstalling it Model 716173 Model 716174 3300 Watts 7000 Watts SERVICING SPARK PLUG Replace spark plug if electrodes are pitted burned or porcelain is cracked Use recommended replacement plugs only Spark plug type F6TC Clean area around spark plug Remove and inspect spark plug Inspect electrode gap with wire feeler gauge and reset spark plug gap to 0 028 0 031 in 0 70 0 80 mm Insta...

Page 17: ...r screen clamp and remove screw Inspect screen and replace if torn perforated or otherwise damaged If screen is not damaged clean with commercial solvent Replace spark arrestor cone and screen Secure with clamp and screw Engine Oil Draining Turn and then take out the dipstick Turn off the drain plug and empty the machine oil in the crankshaft Screw on the drain plug and the dipstick Muffler spark ar...

Page 18: ...if rust is present Rust in fuel will cause fuel system problems Cover unit with a suitable protective moisture resistant cover Store unit in a clean and dry area Always store generator and fuel away from heat and ignition sources PREPARE FUEL SYSTEM FOR STORAGE Fuel stored over 30 days can go bad and damage fuel system components Keep fuel fresh or use a fuel stabilizer If a fuel stabilizer is add...

Page 19: ... on the bottom of the bowl Remove the pin that holds the float on Pull the float up Inspect the float needle and make sure the orifice is not gummed up Remove the rubber gasket then clean the orifice if it is dirty Use carb cleaner Do not spray carb cleaner on the float needle or any rubber Engine will not start Gas is not getting to carburetor Make sure gas is getting to the carburetor Remove the...