Zero output from receptacles

Low output voltage with no load

6 Vac or above

Below 6 Vac

High output voltage with no load

Low output voltage under load

Erratic output voltage

Noisy operation

Engine won’t start

1. Engine speed is too slow
2. Open or shorted wiring

3. Faulty capacitor
4. Open/shorted rotor or stator windings

5. Open rectifier

1. Engine speed is too slow
2. Open rectifier
3. Faulty capacitor
4. Open/shorted rotor or stator windings

1. Generator head not magnetized

1. Faulty capacitor
2. Engine speed is too fast

1. Open rectifier
2. Engine speed too slow at full load
3. Excessive load applied

1. Dirty, corroded, or loose wiring

connection

2. Unbalanced load applied

1. Loose generator or engine bolt
2. Short circuit in generator field or load

3. Faulty bearing

1. No fuel.

2. Fuel switch is in closed position.
3. Engine switch is in closed position.
4. Spark plug dirty or wrong gap

1. Adjust engine speed 

2. Clean and reconnect all wiring 

3. Replace capacitor 

4. Test winding resistance, replace winding

if necessary 

5. Test rectifier, replace if necessary 

1. Adjust engine speed 

2. Test rectifier, replace if necessary 

3. Replace capacitor 

4. Test winding resistance, replace winding

if necessary 

1. Re-magnetize generator head 

1. Replace capacitor 

2. Adjust engine speed 

1. Test rectifier, replace if necessary 

2. Adjust engine speed 

3. Reduce the applied load

1. Referring to the wiring diagram, clean

and reconnect all wiring 

2. Remove all loads, then apply each one

individually to determine which one is
causing erratic function

1. Tighten all mountings
2. Test winding resistance, replace field

winding if necessary

Test load devices for shorts. Replace
defective load device.

3. Replace bearing

1. Check fuel. Use a 50:1 mix of gas and oil.

(See page 2)

2. Place fuel switch in open position.
3. Place engine switch in open position.
4. Clean spark plug. Adjust gap. (See page 3)

Replace if necessary.

These diagnostic and repair procedures should be performed by an authorized service center.

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

GN0950 and GN0800 

Summary of Contents for GN0800

Page 1: ...al injury Retain all manuals for future reference 2 Never use this generator for any application other than that specified by the manufacturer Never operate this generator under conditions not approve...

Page 2: ...ns 12 Be sure that all tools and appliances are in good repair and are properly grounded Use devices that have three prong power cords If an extension cord is used be sure that it has three prongs for...

Page 3: ...sulting number is wattage Never exceed the posted maximum wattage for the generator or any individual receptacle Refer to owner s manuals and product tags to determine the wattage of electrical load d...

Page 4: ...ENANCE SCHEDULE R R AC receptacle AC protector Output light 24 F 300VAC Stator assembly Rotor assembly Oil annunciator Oil sensor Oil pilot light OFF ON Engine stop switch T C I unit 10A 6 5A 1 2 3 4...

Page 5: ...nect all wiring 3 Replace capacitor 4 Test winding resistance replace winding if necessary 5 Test rectifier replace if necessary 1 Adjust engine speed 2 Test rectifier replace if necessary 3 Replace c...

Page 6: ...o you C Any failure that results from an accident shipping damage purchaser s abuse neglect or failure to operate products in accordance with instructions provided in the owner s manual s supplied wit...

Page 7: ...pe as recomendados pelo fabricante 4 Certifique se de que o gerador esteja adequadamente aterrado em um fio terra externo antes da opera o Consulte a se o intitulada Instru es sobre aterramento quant...

Page 8: ...o podem reduzir significativamente a possibilidade de ferimento em caso de curto circuito PERIGO AVISO Seguran a geral continua o Um Interrup tor de Circuito de Falha de Aterramento El trico pode n o...

Page 9: ...ortam 13 amps nos modelos de 60 Hz GN950 As tomadas de 240 V suportam 10 A nos modelos de 50 Hz GN800 2 A carga total combinada atrav s de qualquer combina o de tomadas n o deve ultrapassar os limites...

Page 10: ...e a folga Substitua se necess rio Filtro de ar Limpe o Substitua se necess rio Filtro Limpe o de combust vel Substitua se necess rio Descarboniza o Remova os dep sitos de carv o Verifique e ajuste no...

Page 11: ...a do enrolamento e substitua se necess rio 5 Teste o retificador substitua se necess rio 1 Ajuste a velocidade do motor 2 Teste o retificador substitua se necess rio 3 Substitua o capacitor 4 Teste a...

Page 12: ...uso por parte do comprador neglig ncia ou da n o opera o do produto de acordo com as instru es no s manual ais do propriet rio que acompanha m este produto D Servi os de pr entrega isto montagem leo o...

Page 13: ...Notas 13 PG...

Page 14: ...e generador para darle usos no planeados por el fabricante 3 Para mantener y reparar este generador use s lo los productos y partes recomendados por el fabricante 4 Aseg rese de que el generador est b...

Page 15: ...motor de dos tiempos PELIGRO ADVERTENCIA Medidas de Seguridad Continuaci n 2 Se recomienda el uso de un Interruptor de Falla a Tierra IFT Los Interruptores de Falla a Tierra pueden reducir de modo si...

Page 16: ...cos del generador 2 Deje que el motor marche por 2 o 3 minutos sin ninguna carga 3 Apague el interruptor del motor presionando la parte inferior del mismo Esto ahogar al motor 4 Coloque la llave de co...

Page 17: ...distribuidor Art culo Acci n Cada 50 horas Cada 150 horas o cada mes o cada 3 meses PLANIFICACI N DE MANTENIMIENTO escape est n cerradas El pist n empuja una cantidad peque a de aire del agujero de l...

Page 18: ...Examine el rectificador reempl celo si es necesario 3 Reemplace el condensador 4 Mida la resistencia del arrollamiento reempl celo si es necesario 1 Remagnetice cabeza de generador 1 Reemplace el cond...

Page 19: ...or negligencia o incidente al operar productos de acuerdo con las instrucciones proporcion en el manual es del propietario provisto el producto D Servicio de Pre salida es decir ensamblaje aceite o lu...

Page 20: ...Notas...

Reviews: