GN0950 and GN0800 

4. Move the choke/run

switch to the choke
position.

5. Turn engine switch

on by pressing the
top of the switch.

6. Pull the starter rope

with a brisk smooth
motion.

7. Return choke/run switch to the run

position.

8. After each start up, allow engine to

run 2-3 minutes with no load.

Engine speed is 
preset to provide

proper output voltage. Never attempt to
modify or adjust engine speed or output
voltage.

ENGINE BREAK-IN 

The first 25 hours of operation is
considered the break-in period for the
engine. During this time, use a 30:1 mix
of gas and oil and operate at less than
75% of the load limit.

GENERATOR SHUT OFF

1. Remove all electrical load devices

from the generator.

2. Allow the engine to run for 2-3

minutes with no electrical loads.

3. Turn engine switch

off by pressing the
bottom of the
switch. This will stall
the engine.

!

CAUTION

4. Set the fuel switch to the

closed (horizontal)
position.

5. Verify that the generator has

completely stopped.

6. Allow unit to cool before placing in

storage.

LOAD DEVICES

1. The 

120 volt receptacles

(type

NEMA 5-15) are rated for 13 amps
on 60 Hz models (GN950). The 

220

volt receptacles

are rated for 10

amps on 50 Hz models (GN800).

2. Total combined load through any

combination of receptacles must not
exceed rated load limits of generator.

3. Reduce load if

AC Protector
(circuit
breaker) turns
off. Press
button to reset.

NOTE:

Power draw can be calculated

by multiplying volts and amps. The
resulting number is wattage.

Never exceed the posted maximum
wattage for the generator or any
individual receptacle. Refer to owner's

manuals and product tags to determine
the wattage of electrical load devices. 

Long power cords and extension cords
draw additional power. Keep cords at
minimum possible length. See chart
above.

INFREQUENT USAGE

If the generator is used infrequently,
starting difficulty may occur. To help
prevent difficulty starting, the generator
should be run for approximately 30
minutes per week.

STORAGE

If the generator is not to be used for
extended periods of time, the following
pre-storage procedures should be
performed:

1. Drain all fuel from the tank, lines, 

and carburetor.

2. Remove spark plug.

Clean off any carbon
deposits. Check for
discoloration – plug
should be tan in
color. Check the gap;
it should be 0.7 –
0.8mm. 

3. Pour approximately one teaspoon of

oil into spark plug hole.

4. Pull starter cord several times to

spread the oil throughout the
cylinder.

5. Slowly pull the starter cord until

resistance is felt. This indicates that
the piston is moving upward on the

2.5

300

600

1000

600

375

250

5

600

1200

500

300

200

125

7.5

900

1800

350

200

125

100

Amps

Watts

Watts

#8

#10

#12

#14

#16 

120 V

220 V

Wire

Wire

Wire

Wire

Wire

EXTENSION CORDS

MAXIMUM RECOMMENDED LENGTHS (IN FEET)

Operation 

(Continued)

Computer

300

CD Player

100

VCR

100

Radio

100

Television

300

Receiver

420

Microwave

800

Blender

300

Load Device

Watts

Load Device

Watts

Hand Vacuum

500

Power Drill

500

Hedge Trimmer

500

Weed Whip

500

Coffee Maker

1200

Slow Cooker/Frying Pan

200

Outdoor Lights

75-150

Bug Light

50

ESTIMATED POWER USAGE (WATTS)

Maintenance

Summary of Contents for GN0800

Page 1: ...al injury Retain all manuals for future reference 2 Never use this generator for any application other than that specified by the manufacturer Never operate this generator under conditions not approve...

Page 2: ...ns 12 Be sure that all tools and appliances are in good repair and are properly grounded Use devices that have three prong power cords If an extension cord is used be sure that it has three prongs for...

Page 3: ...sulting number is wattage Never exceed the posted maximum wattage for the generator or any individual receptacle Refer to owner s manuals and product tags to determine the wattage of electrical load d...

Page 4: ...ENANCE SCHEDULE R R AC receptacle AC protector Output light 24 F 300VAC Stator assembly Rotor assembly Oil annunciator Oil sensor Oil pilot light OFF ON Engine stop switch T C I unit 10A 6 5A 1 2 3 4...

Page 5: ...nect all wiring 3 Replace capacitor 4 Test winding resistance replace winding if necessary 5 Test rectifier replace if necessary 1 Adjust engine speed 2 Test rectifier replace if necessary 3 Replace c...

Page 6: ...o you C Any failure that results from an accident shipping damage purchaser s abuse neglect or failure to operate products in accordance with instructions provided in the owner s manual s supplied wit...

Page 7: ...pe as recomendados pelo fabricante 4 Certifique se de que o gerador esteja adequadamente aterrado em um fio terra externo antes da opera o Consulte a se o intitulada Instru es sobre aterramento quant...

Page 8: ...o podem reduzir significativamente a possibilidade de ferimento em caso de curto circuito PERIGO AVISO Seguran a geral continua o Um Interrup tor de Circuito de Falha de Aterramento El trico pode n o...

Page 9: ...ortam 13 amps nos modelos de 60 Hz GN950 As tomadas de 240 V suportam 10 A nos modelos de 50 Hz GN800 2 A carga total combinada atrav s de qualquer combina o de tomadas n o deve ultrapassar os limites...

Page 10: ...e a folga Substitua se necess rio Filtro de ar Limpe o Substitua se necess rio Filtro Limpe o de combust vel Substitua se necess rio Descarboniza o Remova os dep sitos de carv o Verifique e ajuste no...

Page 11: ...a do enrolamento e substitua se necess rio 5 Teste o retificador substitua se necess rio 1 Ajuste a velocidade do motor 2 Teste o retificador substitua se necess rio 3 Substitua o capacitor 4 Teste a...

Page 12: ...uso por parte do comprador neglig ncia ou da n o opera o do produto de acordo com as instru es no s manual ais do propriet rio que acompanha m este produto D Servi os de pr entrega isto montagem leo o...

Page 13: ...Notas 13 PG...

Page 14: ...e generador para darle usos no planeados por el fabricante 3 Para mantener y reparar este generador use s lo los productos y partes recomendados por el fabricante 4 Aseg rese de que el generador est b...

Page 15: ...motor de dos tiempos PELIGRO ADVERTENCIA Medidas de Seguridad Continuaci n 2 Se recomienda el uso de un Interruptor de Falla a Tierra IFT Los Interruptores de Falla a Tierra pueden reducir de modo si...

Page 16: ...cos del generador 2 Deje que el motor marche por 2 o 3 minutos sin ninguna carga 3 Apague el interruptor del motor presionando la parte inferior del mismo Esto ahogar al motor 4 Coloque la llave de co...

Page 17: ...distribuidor Art culo Acci n Cada 50 horas Cada 150 horas o cada mes o cada 3 meses PLANIFICACI N DE MANTENIMIENTO escape est n cerradas El pist n empuja una cantidad peque a de aire del agujero de l...

Page 18: ...Examine el rectificador reempl celo si es necesario 3 Reemplace el condensador 4 Mida la resistencia del arrollamiento reempl celo si es necesario 1 Remagnetice cabeza de generador 1 Reemplace el cond...

Page 19: ...or negligencia o incidente al operar productos de acuerdo con las instrucciones proporcion en el manual es del propietario provisto el producto D Servicio de Pre salida es decir ensamblaje aceite o lu...

Page 20: ...Notas...

Reviews: