background image

5

FP2603, FP2604

www.chpower.com

Operation (Continued) 

6 .   Adjust regulator to proper pressure 

for tool or tire . Operate tool per 
instructions . 

As air is depleted from the tank by 
use of a tire chuck, tool, etc ., the 
compressor will restart automatically 
at its preset “cut-in” pressure . When 
a tool is being used continuously, 
the compressor will cycle on and off 
automatically . 
7 .   Turn switch to OFF 

( O )

 position, 

unplug power cord and drain 
tank of air when finished using 
compressor .

Maintenance

Disconnect power source 
then release all pressure from 
the system before attempting 
to install, service, relocate or perform 
any maintenance. Service should be 
performed by an authorized service 
representative.

The compressor should be checked 
often for any visible problems and the 
following maintenance procedures 
should be performed each time the 
compressor is used .

ASME SAFETy vALvE

 

Do not remove or 

  attempt to adjust 

the safety valve!

Check the safety valve by performing 
the following steps: 
1 .   Plug the compressor in and run until 

shut off pressure is reached (see 
Operating Procedure) . 

2 .   Wearing safety glasses, pull the 

ring on the safety valve to release 
pressure from compressor tank . Use 
your other hand to deflect fast-
moving air from being directed 
toward your face .

3 .   The safety valve should 

automatically close at approximately 
40-50 psi . If the safety valve does 
not allow air to be released when 
you pull on the ring, or if it does 
not close automatically, it MUST be 
replaced . 

DRAIN TANK

With compressor shut off and pressure 
released, drain moisture from tank by 
opening drain valve underneath tank .

CLEANING

Turn power OFF and clean dust and dirt 
from pump cover, tank, and air lines .

IMPORTANT:

 Unit should be located as 

far from spraying area as hose will allow 
to prevent over-spray from clogging air 
filter .

LUBRICATION

This is an oilless type compressor 
requiring no lubrication .

END OF OPERATION/STORAGE

1 .  Turn ON / OFF

 ( I / O )

 switch to the 

OFF

 ( O ) 

position .

2 .  Unplug power cord from wall outlet 

and wrap around handle area to 
prevent damage when not in use .

3 .  Wearing safety glasses drain tank of 

air by pulling the ring on the safety 
valve . Use other hand to deflect 
fast moving air from being directed 
toward your face .

4 .  Drain tank of condensation by 

opening drain valve on bottom of 
tank . Tank pressure should be below 
10 psi when draining tank .  

5 .  Air hose should be disconnected 

from compressor and hung open 
ends down to allow any moisture to 
drain .

6 .  Compressor and hose should be 

stored in a cool, dry place .

Figure 5 - Safety valve

Figure 6 - Drain tank

Summary of Contents for FP2603

Page 1: ...to tighten fittings bolts etc before putting unit into service In case of questions damaged or missing parts please call 1 800 543 6400 for customer assistance Have the date code model number and par...

Page 2: ...e hearing protection when operating the pump or unit 6 Do not stand on or use the pump or unit as a handhold 7 Before each use inspect compressed air system and electrical components for signs of dama...

Page 3: ...from inadequate wiring etc the spraying area as possible to minimize overspray accumulation on the compressor 19 When spraying or cleaning with solvents or toxic chemicals follow the instructions pro...

Page 4: ...uilding pressure properly ASME Safety Valve This valve automatically releases air if the tank pressure exceeds the preset maximum Handle Designed to move the compressor Drain Valve This valve is locat...

Page 5: ...Use your other hand to deflect fast moving air from being directed toward your face 3 The safety valve should automatically close at approximately 40 50 psi If the safety valve does not allow air to...

Page 6: ...e or purchase unit with higher air delivery SCFM Tank pressure drops when compressor shuts off 1 Open tank drain valve 1 Close tank drain valve 2 Loose connections fittings tubing air hose any connect...

Page 7: ...7 FP2603 FP2604 Notes www chpower com...

Page 8: ...usfeld Serial number if any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 45030 U S A Operating Instructions and Parts Manual Figure 7 Repla...

Page 9: ...train Relief t 1 17 Screw 1 18 Washer with Teeth 1 19 Terminal 1 20 Outlet Gauge FP204013AV 1 Ref No Description Part No Qty 21 Tank Gauge FP204012AV 1 22 Regulator and Manifold Assembly FP018300AV 1...

Page 10: ...xcluded from coverage under this limited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered under t...

Page 11: ...chercher toute trace de dommage susceptible de s tre produit en cours de transport Veiller serrer tout raccord boulon etc avant de mettre ce produit en service En cas de dommage ou de parties manquant...

Page 12: ...iliaris es avec ces r gles d utilisation doivent tre autoris es se servir du compresseur 4 Garder les visiteurs l cart de et NE JAMAIS permettre les enfants dans l endroit de travail 5 Utiliser des lu...

Page 13: ...cendie pr cautions de pulv risation Ne pas pulv riser les mat riaux inflammables dans un endroit de flamme ouverte ni pr s d une source d ignition y compris le compresseur 16 Ne pas fumer pendant la p...

Page 14: ...nd on met en marche le compresseur ON le pressostat teint le compresseur automatiquement lorsque la pression du r servoir atteint la pression maximum d arr t coupe Si pression du r servoir d passe la...

Page 15: ...faire fonctionner jusqu ce qu il atteigne la pression d arr t voir proc dure de fonctionnement 2 Porter des lunettes de s curit tirer l anneau sur la soupape de s ret pour d gager la pression du r ser...

Page 16: ...il plus puissant SCFM Pression du r servoir tombe lorsque le compresseur s arr te 1 Robinet de vidange du r servoir ouvert 1 Fermer le robinet de vidange du r servoir 2 Raccordements d gag s raccords...

Page 17: ...17 Fr FP2603 FP2604 Notes...

Page 18: ...e technique appeler 1 800 543 6400 S il vous pla t fournir l information suivante Adresser toute correspondance Num ro de Mod le Campbell Hausfeld Num ro de s rie si pr sent Attn Customer Service Desc...

Page 19: ...18 Rondelle dents 1 19 Borne 1 20 Jauge de sortie FP204013AV 1 Ref No Description Part No Qty 21 Manom tre du r servoir FP204012AV 1 22 R gulateur et collecteur assemblage FP018300AV 1 23 Soupape de s...

Page 20: ...ur qui est fournie avec le produit G Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresseurs a Toutes pi ces d tach es endommag es pendant l exp dition n importe...

Page 21: ...dadosamente para verificar si se han producido da os durante el transporte Aseg rese de apretar todos los accesorios pernos etc que est n sueltos antes de poner la unidad en servicio En el caso de que...

Page 22: ...esor s lo debe ser usado por personas que est n bien familiarizadas con las reglas de seguridad y de manejo 4 Mantenga a los visitantes alejados y NUNCA permita la presencia de ni os en el rea de trab...

Page 23: ...enchufe si ste no entra en el tomacorrientes mande a instalar un tomacorrientes adecuado con un electricista calificado Un cableado inadecuado provocar da os por sobrecalentamiento cortocircuitos e in...

Page 24: ...ticas o desconectar la manguera de la salida El man metro que se encuentra a la izquierda muestra la presi n del tanque indicando que el compresor est acumulando presi n de forma adecuada V lvula de...

Page 25: ...Enchufe el compresor y h galo funcionar hasta que se alcance la presi n de corte consulte Funcionamiento 2 Usando gafas de protecci n tire del anillo de la v lvula de seguridad para liberar la presi n...

Page 26: ...2 Uso excesivo el compresor es demasiado peque o 2 Disminuya el uso o compre una unidad que ofrezca una entrega de aire mayor SCFM La presi n del tanque disminuye cuando se apaga el compresor 1 V lvu...

Page 27: ...usa s Acci n a Tomar La v lvula de seguridad se abre 1 Presostato defectuoso 1 Cambie el interruptor de presi n 2 V lvula de seguridad defectuosa 2 Cambie la v lvula de retenci n con un repuesto origi...

Page 28: ...l Distribuidor M s Cercano a Su Domicilio Sirvase darnos la siguiente informaci n Dirija toda la correspondencia a N mero del modelo Campbell Hausfeld C digo impreso Attn Customer Service Descripci n...

Page 29: ...1 17 Tornillo 1 18 Arandela con dientes 1 19 Terminal 1 20 Man metro de salida FP204013AV 1 Ref No Description Part No Qty 21 Man metro del tanque FP204012AV 1 22 Regulador y ensamble del distribuido...

Page 30: ...stra con el producto G Art culos adicionales no cubiertos bajo esta garant a 1 Todos los Compresores a Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u op...

Page 31: ...Notes Notas FP2603 FP2604 31...

Page 32: ...Notes Notas FP2603 FP2604 Operating Instructions and Parts Manual Instructions d utilisation et manual de pi ces Manual de Instrucciones de Operaci n y Lista de Partes 32...

Reviews: