DEFINITION OF TERMS
ON/OFF Switch ( I / O )

 - Push switch to 

the ON

 ( I )

 position to turn compressor 

on . Push switch to the OFF 

( O )

 position 

to turn compressor off . This switch 
should be in the OFF

 ( O )

 position 

when connecting / disconnecting power 
cord from electrical outlet or when 
changing tools .

Pressure Switch (located internally)- 

When the compressor is turned ON, 
this switch will shut compressor off 
automatically when tank pressure 
reaches maximum shut-off / cut-out 
pressure . If compressor remains on and 
air is depleted from tank, this switch 
will allow compressor to automatically 
restart at the restart / cut-in pressure .

Regulator

 - The regulator controls the 

amount of air pressure released at the 
hose outlet . Turning the regulator knob 
clockwise (to the right) will increase air 
pressure at the outlet . Turning the knob 
counter-clockwise (to the left) will lower 
air pressure to the outlet . Turning knob 
fully counter-clockwise will shut off flow 
of air completely .

Pressure Gauges

 - There are two 

gauges located next to the regulator . 
These gauges read air pressure in 
pounds per square inch (psi) . The 
gauge on the right shows pressure at 
the outlet . Make sure this gauge reads 
ZERO (by adjusting the regulator) 
BEFORE changing air tools or 
disconnecting hose from outlet . The 
gauge on the left shows pressure in the 
tank indicating compressor is building 
pressure properly . 

ASME Safety valve

 - This valve 

automatically releases air if the tank 
pressure exceeds the preset maximum .

Handle

 - Designed to move the 

compressor .

Drain valve

 - This valve is located on 

the bottom of the tank . Use this valve 
to drain moisture from the tank daily to 
reduce the risk of corrosion .

Motor Protection

 - If the unit is over 

worked, a thermal limiter will shut unit 
off . If this happens, switch unit to OFF, 
wait 30 minutes to cool, turn ON again 
to resume work .

LUBRICATION

This is an oilless product and 

DOES NOT 

require lubrication to operate .

BEFORE FIRST STARTUP BREAK-IN 
PROCEDURE

(Complete this procedure before using 
compressor for the first time . Once  
completed, it is not necessary to repeat .)
1 .   Turn regulator knob fully clockwise 

(to the right) to open air flow .

2 .   Do not attach a hose or any other 

fitting to the compressor .

3 .   Turn ON/OFF switch to OFF position .
4 .   Plug in power cord .
5 .   Turn ON/OFF switch to ON position . 

Allow compressor to run for 5 
minutes .

6 .   Turn ON/OFF switch to OFF position .
7 .   Unplug power cord .

OPERATING PROCEDURE

1 .   Turn switch to OFF

 ( O )

 position and 

plug in power cord .

2 .   Turn regulator knob 

counterclockwise to close air flow .

3 .   Turn switch to ON 

( I )

 position .

4 .   Compressor will build to maximum 

pressure and shut off .

5 .   With hose attached to outlet of 

compressor, attach tire chuck or 
other tool to open end of hose . 

Figure 3 - ON/OFF switch

ON 

Position

OFF 

Position

Figure 4 - Drain valve

Figure 2 - Unit identification

ON/OFF Switch

Handle

Air Outlet

Tank Drain Valve

Power Cord 

with Plug

Outlet Gauge

Regulator

Tank Gauge

ASME  

Safety Valve

Shroud

Tank

Summary of Contents for FP2603

Page 1: ...to tighten fittings bolts etc before putting unit into service In case of questions damaged or missing parts please call 1 800 543 6400 for customer assistance Have the date code model number and par...

Page 2: ...e hearing protection when operating the pump or unit 6 Do not stand on or use the pump or unit as a handhold 7 Before each use inspect compressed air system and electrical components for signs of dama...

Page 3: ...from inadequate wiring etc the spraying area as possible to minimize overspray accumulation on the compressor 19 When spraying or cleaning with solvents or toxic chemicals follow the instructions pro...

Page 4: ...uilding pressure properly ASME Safety Valve This valve automatically releases air if the tank pressure exceeds the preset maximum Handle Designed to move the compressor Drain Valve This valve is locat...

Page 5: ...Use your other hand to deflect fast moving air from being directed toward your face 3 The safety valve should automatically close at approximately 40 50 psi If the safety valve does not allow air to...

Page 6: ...e or purchase unit with higher air delivery SCFM Tank pressure drops when compressor shuts off 1 Open tank drain valve 1 Close tank drain valve 2 Loose connections fittings tubing air hose any connect...

Page 7: ...7 FP2603 FP2604 Notes www chpower com...

Page 8: ...usfeld Serial number if any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 45030 U S A Operating Instructions and Parts Manual Figure 7 Repla...

Page 9: ...train Relief t 1 17 Screw 1 18 Washer with Teeth 1 19 Terminal 1 20 Outlet Gauge FP204013AV 1 Ref No Description Part No Qty 21 Tank Gauge FP204012AV 1 22 Regulator and Manifold Assembly FP018300AV 1...

Page 10: ...xcluded from coverage under this limited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered under t...

Page 11: ...chercher toute trace de dommage susceptible de s tre produit en cours de transport Veiller serrer tout raccord boulon etc avant de mettre ce produit en service En cas de dommage ou de parties manquant...

Page 12: ...iliaris es avec ces r gles d utilisation doivent tre autoris es se servir du compresseur 4 Garder les visiteurs l cart de et NE JAMAIS permettre les enfants dans l endroit de travail 5 Utiliser des lu...

Page 13: ...cendie pr cautions de pulv risation Ne pas pulv riser les mat riaux inflammables dans un endroit de flamme ouverte ni pr s d une source d ignition y compris le compresseur 16 Ne pas fumer pendant la p...

Page 14: ...nd on met en marche le compresseur ON le pressostat teint le compresseur automatiquement lorsque la pression du r servoir atteint la pression maximum d arr t coupe Si pression du r servoir d passe la...

Page 15: ...faire fonctionner jusqu ce qu il atteigne la pression d arr t voir proc dure de fonctionnement 2 Porter des lunettes de s curit tirer l anneau sur la soupape de s ret pour d gager la pression du r ser...

Page 16: ...il plus puissant SCFM Pression du r servoir tombe lorsque le compresseur s arr te 1 Robinet de vidange du r servoir ouvert 1 Fermer le robinet de vidange du r servoir 2 Raccordements d gag s raccords...

Page 17: ...17 Fr FP2603 FP2604 Notes...

Page 18: ...e technique appeler 1 800 543 6400 S il vous pla t fournir l information suivante Adresser toute correspondance Num ro de Mod le Campbell Hausfeld Num ro de s rie si pr sent Attn Customer Service Desc...

Page 19: ...18 Rondelle dents 1 19 Borne 1 20 Jauge de sortie FP204013AV 1 Ref No Description Part No Qty 21 Manom tre du r servoir FP204012AV 1 22 R gulateur et collecteur assemblage FP018300AV 1 23 Soupape de s...

Page 20: ...ur qui est fournie avec le produit G Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresseurs a Toutes pi ces d tach es endommag es pendant l exp dition n importe...

Page 21: ...dadosamente para verificar si se han producido da os durante el transporte Aseg rese de apretar todos los accesorios pernos etc que est n sueltos antes de poner la unidad en servicio En el caso de que...

Page 22: ...esor s lo debe ser usado por personas que est n bien familiarizadas con las reglas de seguridad y de manejo 4 Mantenga a los visitantes alejados y NUNCA permita la presencia de ni os en el rea de trab...

Page 23: ...enchufe si ste no entra en el tomacorrientes mande a instalar un tomacorrientes adecuado con un electricista calificado Un cableado inadecuado provocar da os por sobrecalentamiento cortocircuitos e in...

Page 24: ...ticas o desconectar la manguera de la salida El man metro que se encuentra a la izquierda muestra la presi n del tanque indicando que el compresor est acumulando presi n de forma adecuada V lvula de...

Page 25: ...Enchufe el compresor y h galo funcionar hasta que se alcance la presi n de corte consulte Funcionamiento 2 Usando gafas de protecci n tire del anillo de la v lvula de seguridad para liberar la presi n...

Page 26: ...2 Uso excesivo el compresor es demasiado peque o 2 Disminuya el uso o compre una unidad que ofrezca una entrega de aire mayor SCFM La presi n del tanque disminuye cuando se apaga el compresor 1 V lvu...

Page 27: ...usa s Acci n a Tomar La v lvula de seguridad se abre 1 Presostato defectuoso 1 Cambie el interruptor de presi n 2 V lvula de seguridad defectuosa 2 Cambie la v lvula de retenci n con un repuesto origi...

Page 28: ...l Distribuidor M s Cercano a Su Domicilio Sirvase darnos la siguiente informaci n Dirija toda la correspondencia a N mero del modelo Campbell Hausfeld C digo impreso Attn Customer Service Descripci n...

Page 29: ...1 17 Tornillo 1 18 Arandela con dientes 1 19 Terminal 1 20 Man metro de salida FP204013AV 1 Ref No Description Part No Qty 21 Man metro del tanque FP204012AV 1 22 Regulador y ensamble del distribuido...

Page 30: ...stra con el producto G Art culos adicionales no cubiertos bajo esta garant a 1 Todos los Compresores a Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u op...

Page 31: ...Notes Notas FP2603 FP2604 31...

Page 32: ...Notes Notas FP2603 FP2604 Operating Instructions and Parts Manual Instructions d utilisation et manual de pi ces Manual de Instrucciones de Operaci n y Lista de Partes 32...

Reviews: