General Safety Information 

(Continued) 

GROUNDING INSTRUCTIONS

1 .   This product is for use on a nominal 

120 volt circuit and has a grounding 
plug that looks like the plug 
illustrated in Figure 1 . Make sure the 
product is connected to an outlet 
having the same configuration 
as the plug . This product must 
be grounded . In the event of an 
electrical short circuit, grounding 
reduces risk of electrical shock by 
providing an escape wire for electric 
current . This product is equipped 
with a cord having a grounding 
wire with an appropriate grounding 
plug . Plug must be plugged into an 
outlet that is properly installed and 
grounded in accordance with all 
local codes and ordinances .

Improper use of grounding 
plug can result in a possible 
risk of electrical shock!
 

Do not use a  

  grounding adapter 

with this product!

2 .   If repair or replacement of cord or 

plug is necessary, do not connect 
grounding wire to either flat blade 
terminal . The wire with insulation 
having an external surface that 
is green (with or without yellow 
stripes) is the grounding wire .

 

Never connect  

  green (or green and 

yellow) wire to a live terminal.

3 .   Check with a qualified electrician or 

serviceman if grounding instructions 
are not completely understood, or 
if in doubt as to whether product is 
properly grounded . Do not modify 
plug provided; if it will not fit outlet, 
have proper outlet installed by a 
qualified electrician .

 

Overheating, short  

  circuiting and fire 

damage will result from inadequate 
wiring, etc.

the spraying area as possible to 
minimize overspray accumulation on 
the compressor .

 19 . When spraying or cleaning with 

solvents or toxic chemicals, follow 
the instructions provided by the 
chemical manufacturer .

HOSE PRECAUTIONS

 20 . Inspect hose before use .

Do not exceed working 
pressure marked on hose.

 

Do not twist, bend knot, or abrade 
hose.

 21 . Do not wrap hose around body .

 

Keep away from hot surfaces and 
chemicals.

Installation

LOCATION

It is extremely important to use the 
compressor in a clean, well ventilated 
area where the surrounding air 
temperature will not be more than 
100°F .
A minimum clearance of 18 inches 
between the compressor and a wall is 
required because objects could obstruct 
air flow .

 

Do not  locate the  

  compressor air inlet 

near steam, paint spray, sandblast areas 
or any other source of contamination. 
This debris will damage the motor.

TEST

RESET

Grounding pin

Grounded 

outlet

Figure 1 - Grounding method

MOISTURE IN COMPRESSED AIR

Moisture in compressed air will form into droplets as it comes from an air 
compressor pump . When humidity is high or when a compressor is in continuous use 
for an extended period of time, this moisture will collect in the tank . When using a 
paint spray or sandblast gun, this water will be carried from the tank through the 
hose, and out of the gun as droplets mixed with the spray material .

IMPORTANT: 

This condensation will cause water spots in a paint job, especially 

when spraying other than water based paints . If sandblasting, it will cause the sand 
to cake and clog the gun, rendering it ineffective . A filter in the air line, located as 
near to the gun as possible, will help eliminate this moisture .

Summary of Contents for FP2603

Page 1: ...to tighten fittings bolts etc before putting unit into service In case of questions damaged or missing parts please call 1 800 543 6400 for customer assistance Have the date code model number and par...

Page 2: ...e hearing protection when operating the pump or unit 6 Do not stand on or use the pump or unit as a handhold 7 Before each use inspect compressed air system and electrical components for signs of dama...

Page 3: ...from inadequate wiring etc the spraying area as possible to minimize overspray accumulation on the compressor 19 When spraying or cleaning with solvents or toxic chemicals follow the instructions pro...

Page 4: ...uilding pressure properly ASME Safety Valve This valve automatically releases air if the tank pressure exceeds the preset maximum Handle Designed to move the compressor Drain Valve This valve is locat...

Page 5: ...Use your other hand to deflect fast moving air from being directed toward your face 3 The safety valve should automatically close at approximately 40 50 psi If the safety valve does not allow air to...

Page 6: ...e or purchase unit with higher air delivery SCFM Tank pressure drops when compressor shuts off 1 Open tank drain valve 1 Close tank drain valve 2 Loose connections fittings tubing air hose any connect...

Page 7: ...7 FP2603 FP2604 Notes www chpower com...

Page 8: ...usfeld Serial number if any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 45030 U S A Operating Instructions and Parts Manual Figure 7 Repla...

Page 9: ...train Relief t 1 17 Screw 1 18 Washer with Teeth 1 19 Terminal 1 20 Outlet Gauge FP204013AV 1 Ref No Description Part No Qty 21 Tank Gauge FP204012AV 1 22 Regulator and Manifold Assembly FP018300AV 1...

Page 10: ...xcluded from coverage under this limited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered under t...

Page 11: ...chercher toute trace de dommage susceptible de s tre produit en cours de transport Veiller serrer tout raccord boulon etc avant de mettre ce produit en service En cas de dommage ou de parties manquant...

Page 12: ...iliaris es avec ces r gles d utilisation doivent tre autoris es se servir du compresseur 4 Garder les visiteurs l cart de et NE JAMAIS permettre les enfants dans l endroit de travail 5 Utiliser des lu...

Page 13: ...cendie pr cautions de pulv risation Ne pas pulv riser les mat riaux inflammables dans un endroit de flamme ouverte ni pr s d une source d ignition y compris le compresseur 16 Ne pas fumer pendant la p...

Page 14: ...nd on met en marche le compresseur ON le pressostat teint le compresseur automatiquement lorsque la pression du r servoir atteint la pression maximum d arr t coupe Si pression du r servoir d passe la...

Page 15: ...faire fonctionner jusqu ce qu il atteigne la pression d arr t voir proc dure de fonctionnement 2 Porter des lunettes de s curit tirer l anneau sur la soupape de s ret pour d gager la pression du r ser...

Page 16: ...il plus puissant SCFM Pression du r servoir tombe lorsque le compresseur s arr te 1 Robinet de vidange du r servoir ouvert 1 Fermer le robinet de vidange du r servoir 2 Raccordements d gag s raccords...

Page 17: ...17 Fr FP2603 FP2604 Notes...

Page 18: ...e technique appeler 1 800 543 6400 S il vous pla t fournir l information suivante Adresser toute correspondance Num ro de Mod le Campbell Hausfeld Num ro de s rie si pr sent Attn Customer Service Desc...

Page 19: ...18 Rondelle dents 1 19 Borne 1 20 Jauge de sortie FP204013AV 1 Ref No Description Part No Qty 21 Manom tre du r servoir FP204012AV 1 22 R gulateur et collecteur assemblage FP018300AV 1 23 Soupape de s...

Page 20: ...ur qui est fournie avec le produit G Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresseurs a Toutes pi ces d tach es endommag es pendant l exp dition n importe...

Page 21: ...dadosamente para verificar si se han producido da os durante el transporte Aseg rese de apretar todos los accesorios pernos etc que est n sueltos antes de poner la unidad en servicio En el caso de que...

Page 22: ...esor s lo debe ser usado por personas que est n bien familiarizadas con las reglas de seguridad y de manejo 4 Mantenga a los visitantes alejados y NUNCA permita la presencia de ni os en el rea de trab...

Page 23: ...enchufe si ste no entra en el tomacorrientes mande a instalar un tomacorrientes adecuado con un electricista calificado Un cableado inadecuado provocar da os por sobrecalentamiento cortocircuitos e in...

Page 24: ...ticas o desconectar la manguera de la salida El man metro que se encuentra a la izquierda muestra la presi n del tanque indicando que el compresor est acumulando presi n de forma adecuada V lvula de...

Page 25: ...Enchufe el compresor y h galo funcionar hasta que se alcance la presi n de corte consulte Funcionamiento 2 Usando gafas de protecci n tire del anillo de la v lvula de seguridad para liberar la presi n...

Page 26: ...2 Uso excesivo el compresor es demasiado peque o 2 Disminuya el uso o compre una unidad que ofrezca una entrega de aire mayor SCFM La presi n del tanque disminuye cuando se apaga el compresor 1 V lvu...

Page 27: ...usa s Acci n a Tomar La v lvula de seguridad se abre 1 Presostato defectuoso 1 Cambie el interruptor de presi n 2 V lvula de seguridad defectuosa 2 Cambie la v lvula de retenci n con un repuesto origi...

Page 28: ...l Distribuidor M s Cercano a Su Domicilio Sirvase darnos la siguiente informaci n Dirija toda la correspondencia a N mero del modelo Campbell Hausfeld C digo impreso Attn Customer Service Descripci n...

Page 29: ...1 17 Tornillo 1 18 Arandela con dientes 1 19 Terminal 1 20 Man metro de salida FP204013AV 1 Ref No Description Part No Qty 21 Man metro del tanque FP204012AV 1 22 Regulador y ensamble del distribuido...

Page 30: ...stra con el producto G Art culos adicionales no cubiertos bajo esta garant a 1 Todos los Compresores a Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u op...

Page 31: ...Notes Notas FP2603 FP2604 31...

Page 32: ...Notes Notas FP2603 FP2604 Operating Instructions and Parts Manual Instructions d utilisation et manual de pi ces Manual de Instrucciones de Operaci n y Lista de Partes 32...

Reviews: