Product Use Criteria:

• Pump only clean, dry air.
• Operate at 32ºF - 104ºF (0ºC - 40ºC).
• Protect unit from dirt & moisture.
• Do not pump flammable or explosive gases or

use in an atmosphere that contains such gases.

• Protect all surrounding items from exhaust air. This

exhaust air can become very hot.

• Corrosive gases and particulate material will

damage unit. Water vapor, oil-based contaminants
or other liquids must be filtered out.

• Consult your Gast Distributor before using at high

altitudes.

• Oil-Less rotary-vanes require NO lubrication.
• Sealed bearings are grease packed.
• Use of petroleum or hydrocarbon products will

reduce carbon-vane service life.

Thank you for purchasing this Gast product.  It is manufactured to the highest standards

using quality materials.  Please follow all recommended maintenance, operational

and safety instructions and you will receive years of trouble free service.

General information

• Model numbers ending in “X”

have automatic thermal

protectors which protect the motor by shutting the motor

off if it overheats.  The motor will automatically restart
once the motor has cooled.

PART NO. 70 - 290 G375PL  (REV-K) 

Model #1023-101Q Shown

Model #1023-V103 Shown

Model #0523-101 Shown

PLEASE READ THIS MANUAL COMPLETELY BEFORE INSTALLING AND USING

THIS PRODUCT. SAVE THIS MANUAL FOR FUTURE REFERENCE AND

KEEP IN THE VICINITY OF THE PRODUCT.

 ® Registered Trademark/™ Trademark of Gast Manufacturing Inc. ©Copyright 2012 Gast Manufacturing Inc. All Rights Reserved.

www.gastmfg.com

ISO 9001 CERTIFIED

Summary of Contents for 23 SERIES OIL-LESS

Page 1: ...duce carbon vane service life Thank you for purchasing this Gast product It is manufactured to the highest standards using quality materials Please follow all recommended maintenance operational and safety instructions and you will receive years of trouble free service General information Model numbers ending in X have automatic thermal protectors which protect the motor by shutting the motor off ...

Page 2: ...rotective switches to provide protection Fuses act as short circuit protection for the motor not as protection against overload Incoming line fuses help to withstand the motorʼs starting current Motor starters with thermal magnetic overload or circuit breakers protect motor from overload or reduced voltage conditions The wiring diagram attached to the product provides required electrical informati...

Page 3: ...ming maintenance on this product Failure to follow these instructions can result in death fire or electrical shock Injury Hazard Product surfaces become very hot during operation allow product surfaces to cool before handling Air stream from product may contain solid or liquid material that can result in eye or skin damage wear proper eye protection Flush this product in a well ventilated area Fai...

Page 4: ...r damage 11 Reinstall muffler box Torque bolts to 90 120 in lb Check that all external accessories such as relief valves and gauges are attached and are not damaged before re operating product Electrical Shock Hazard Disconnect electrical power supply cord before installing service kit If product is hard wired into system disconnect electrical power at the circuit breaker or fuse box before instal...

Page 5: ...4 END PLATE 1 AK516A AK501 AK516A AK501 AK516A 5 GASKET 1 AK521 AK521 6 MUFFLER BOX 1 AK519 AK519 7 O RING 2 AK473 AK473 8 FELT 2 AK524 AK524 9 END CAP 2 AK510 AK510 10 END CAP ASSEMBLY 2 AK526 AK526 11 FILTER MUFFLER 1 AK840A AK840A 12 FOOT SUPPORT 1 AC136 AC136 13 ELBOW 2 AD997 14 MUFFLER ASSEMBLY 1 V425L 15 JAR 2 AA125A 16 COVER 1 AV427A 17 FELT FILTER 4 B344A 18 SUPPORT 1 B345A 19 COVER GASKET...

Page 6: ... a NIPPLE 2 BA714 14 JAR 2 AA805 15 COVER GASKET 2 AA405 16 COVER ASSEMBLY 1 AV805B 17 MUFFLER ASSEMBLY 1 AC434 1 18 COUPLING 2 AC391 19 CARTRIDGE 2 AC393 20 END CAP ASSEMBLY 2 AC394 21 MUFFLER PLATE 1 AC395 22 STUD 2 AC396 23 FILTER ASSEMBLY 1 AB599 24 COVER ASSEMBLY 1 AV805APC 25 FILTER ASSEMBLY 1 AC433 1 SERVICE KIT 1 K479A K479 K479A K479 K479A K575A For 1423 Models only Shipped unattached EXP...

Page 7: ...R INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND however arising including but not limited to those for use of any products loss of time inconvenience lost profit labor charges or other incidental or consequential damages with respect to persons business or property whether as a result of breach of warranty negligence or otherwise Notwithstanding any other provision of this warranty BUYERʼS REMEDY ...

Page 8: ...offset powder in pump Inspect and clean Motor not wired correctly Check wiring diagram and line voltage Gast Manufacturing Inc P O Box 97 2300 S Highway M139 Benton Harbor MI 49023 0097 Ph 269 926 6171 FAX 269 925 8288 www gastmfg com Gast Group Limited United Kingdom Unit 11 The I O Centre Nash Road Redditch B98 7AS United Kingdom ph 44 0 1527 504040 Fax 44 0 1527 525262 www gastmfg com Gast Hong...