D-13
Scanner
®
2000 microEFM
Appendix D
RTD Configuration
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Access
Default
2300
8FC
PT - Units
U16
R/W
501
2301
8FD
PT - Time Base
0 = Second
1 = Minute
2 = Hour
3 = Day
U16
R/W
0
2302
8FE
PT - Sampling Period (sec)
U16
R/W
5
2303
8FF
PT - Dampening Factor
U16
R/W
0
2304
900
PT - Input Configuration
U16
R/W
0
2305
901
PT - Override Enable
0 - Disabled
1 - Enabled
2 - Flow Dependent Averaging
U16
R/W
2
2306
902
PT - Override Value
FP
R/W
0.00
2308
904
PT - Fail Value
FP
R/W
60.00 Deg F
2310
906
PT - Low Input Cutoff
FP
R/W
-100.00 Deg F
2312
908
PT - Low Flow Cutoff
FP
R/W
-100.00
2314
90A
PT - Sensor Range Low
FP
RO
-40.00 Deg F
2316
90C
PT - Sensor Range High
FP
RO
300.00 Deg F
2318
90E
PT - Units Scale Factor
FP
R/W
1.80
2320
910
PT - Units Offset Factor
FP
R/W
32.00
2322
912
PT - Unit Description 1
LCD
R/W
—
2323
913
PT - Unit Description 2
LCD
R/W
—
2324
914
PT - Unit Description 3
LCD
R/W
—
RTD Calibration
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Access
Default
2330
91A
PT - Calibration Type
1
U16
R/W
0
2331
91B
PT - Nominal Value
FP
R/W
1.00
2333
91D
PT - Calibration Absolute Offset
FP
R/W
0.00
2335
91F
PT - Calibration Actual 1
FP
R/W
0.00
2337
921
PT - Calibration Actual 2
FP
R/W
0.00
2339
923
PT - Calibration Actual 3
FP
R/W
0.00
2341
925
PT - Calibration Actual 4
FP
R/W
0.00
2343
927
PT - Calibration Actual 5
FP
R/W
0.00
2345
929
PT - Calibration Actual 6
FP
R/W
0.00
2347
92B
PT - Calibration Actual 7
FP
R/W
0.00
2349
92D
PT - Calibration Actual 8
FP
R/W
0.00
2351
92F
PT - Calibration Actual 9
FP
R/W
0.00
Summary of Contents for Scanner 2000 microEFM
Page 1: ...NUFLO Scanner 2000 microEFM Hardware User Manual Manual No 9A 30165023 Rev 10 ...
Page 26: ...26 Section 1 Scanner 2000 microEFM ...
Page 104: ...A 18 Appendix A Scanner 2000 microEFM ...
Page 106: ...B 2 Appendix B Scanner 2000 microEFM ...