12
Section 1
Scanner
®
2000 microEFM
Product Identification
Each device is labeled with a serial tag that identifies the product by model number and serial number
and identifies the maximum operating pressure, working pressure, and differential pressure of the integral
MVT (Figure 1.4). The tag content depicted in Figure 1.4 shows the electrical protection afforded by SIRA
certification. CSA-approved products are marked accordingly with the respective ratings and symbols.
Units approved for custody transfer by Measurement Canada will have an additional label attached, bearing
the MC approval number. See
Measurement Canada Seal Kit, page
for details.
Equipment Group II, Category 2 (hazardous conditions
are likely to occur in normal operation occasionally (>10<1000 hours/year)
Explosive Atmosphere: Gas, Dust
Flameproof for explosive gas environments other than
mines; temperature class
CE marking and number of notified
body responsible for production
Explosion-proof marking
Certification number
Temperature tested for dust and suitable for use in
Zone 21 area; ingress protection: dust-tight and protected
against the effects of continuous immersion in water;
maximum surface temperature: 85°C
Figure 1.4—Device serial tag
Hardware Options
The following hardware options are available for customizing the Scanner 2000 to a user’s specific needs.
Input/Output Expansion Board
An expansion board (Part No. 9A-30188004) allows the instrument to support a differential pressure meter
run and two turbine meter runs simultaneously. The board features a turbine input, a pulse input, two analog
inputs, an analog output, and 256 KB of memory. See
Input/Output Expansion Board (Not Available with
for wiring diagrams.
Standard Device
(Main Board Only)
Expanded Device
(Main Board and Expansion Board)
Integral MVT
Integral MVT
2 RS-485 communication ports
2 RS-485 communication ports
1 process temperature input
1 process temperature input
1 turbine meter input
2 turbine meter inputs
—
1 configurable pulse input
—
2 configurable analog inputs (1-5V)
1 configurable digital output
1 configurable digital output
—
1 configurable analog output (4-20 mA)
Important The Scanner 2000 for
F
oundation
™ Fieldbus does not support the I/O expansion board
option.
Summary of Contents for Scanner 2000 microEFM
Page 1: ...NUFLO Scanner 2000 microEFM Hardware User Manual Manual No 9A 30165023 Rev 10 ...
Page 26: ...26 Section 1 Scanner 2000 microEFM ...
Page 104: ...A 18 Appendix A Scanner 2000 microEFM ...
Page 106: ...B 2 Appendix B Scanner 2000 microEFM ...