D-16
Appendix D
MC-III™ EXP Flow Analyzer
The following registers are used for hourly, daily and event log registers. Hourly and daily records comprise
five values (registers). See the
Enron Hourly/Daily Record Format, page D-16
. Note that event records are
downloaded one at a time.
Enron Registers
Register
(Decimal)
Register
(Hex)
Description
Data Type
Access
32
0020
Enron Modbus
®
Event Log Register
Refer to Enron
Event Record
Format
RO
700
02BC
Enron Modbus
®
Hourly Log
Refer to Enron
Hourly/Daily
Record Format
RO
701
02BD
Enron Modbus
®
Daily Log
Refer to Enron
Hourly/Daily
Record Format
RO
7000
1B58
Hourly Pointer
[1 to 768]
FP32
RO
7001
1B59
Daily Pointer
[1 to 384]
FP32
RO
7002
1B5A
Event Counter
[1 to 345]
FP32
RO
Enron Hourly/Daily Record Format
Parameter
Data Type
Date
(MMDDYY)
FP32
Time
(HH:MM:SS)
FP32
Total
(base units)
FP32
Flow Time
(number of seconds of flow)
FP32
Supply Voltage
(VDC)
FP32
Summary of Contents for NUFLO MC-III EXP
Page 1: ...NUFLO TM MC III EXP Flow Analyzer User Manual Manual No 9A 50165003 Rev 06 Valves Measurement ...
Page 18: ...12 Section 1 MC III EXP Flow Analyzer ...
Page 35: ...29 MC III EXP Flow Analyzer Section 2 ...
Page 46: ...40 Section 3 MC III EXP Flow Analyzer ...
Page 81: ...75 MC III EXP Flow Analyzer Section 4 ...
Page 93: ...87 MC III EXP Flow Analyzer Section 5 Figure 5 17 Dropdown menu for exporting log data ...
Page 94: ...88 Section 5 MC III EXP Flow Analyzer ...
Page 105: ...99 MC III EXP Flow Analyzer Section 6 ...
Page 114: ...A 9 MC III EXP Flow Analyzer Appendix A ...
Page 121: ...B 7 MC III EXP Flow Analyzer Appendix B ...
Page 123: ...C 2 Appendix C MC III EXP Flow Analyzer ...
Page 141: ...D 18 Appendix D MC III EXP Flow Analyzer ...
Page 143: ......