21
MC-III™ EXP Flow Analyzer
Section 2
Internal Power Supply
The MC-III EXP is shipped with one of three internal power supplies:
•
a CSA-approved 3.6V lithium battery
•
an ATEX-approved 3.6V lithium battery
• a shrink-wrapped alkaline battery pack containing three C-size industrial-grade batteries (available only
with CSA-approved devices)
Low-power microprocessor technology enables the MC-III EXP analyzer to operate approximately 2 years on
a single lithium battery. The lithium battery is strongly recommended for use in extreme temperatures (below
-20°C).
Users can power the instrument from an external power supply or a 4-20 mA current loop, and use the lithium
or alkaline battery (where applicable) as a backup power supply. The use of an alternate power source extends
battery life and helps ensure that timekeeping and volume accumulation will not be interrupted during a
power failure.
External Power Supply
The MC-III EXP can be connected to a remote power supply by a two-conductor cable (Figure 2.8). The
power supply and cable must be capable of supplying 6 to 30 VDC @ 10 mA. This capability is available
only if the 4-20 mA rate output is not used.
A Zener diode (Part No. 1.5KE33CA) must be installed for CE approval.
Caution:
When using the amp & square output with the external power supply, make sure the
power supplies for both features share a common negative (-) terminal or that they are
totally isolated from each other, since both share a common negative (-) connection.
TB
3
TB1
PU
LS
E
IN
PU
T
RE
SE
T
IN
PU
T
TF
M
A&S
GND
EXT POWER
TB2
RS4
85
SL
AV
E
4-2
0
OU
T
PU
LS
E
OU
T
6-3
0 V
DC
POWER
SUPPLY
6 to 30
VDC
J1
J2
RESET
SWITCH
BA
TT
ER
Y
TB3 MARKINGS:
GND = SIGNAL GROUND
Figure 2.8—External power supply wiring
Summary of Contents for NUFLO MC-III EXP
Page 1: ...NUFLO TM MC III EXP Flow Analyzer User Manual Manual No 9A 50165003 Rev 06 Valves Measurement ...
Page 18: ...12 Section 1 MC III EXP Flow Analyzer ...
Page 35: ...29 MC III EXP Flow Analyzer Section 2 ...
Page 46: ...40 Section 3 MC III EXP Flow Analyzer ...
Page 81: ...75 MC III EXP Flow Analyzer Section 4 ...
Page 93: ...87 MC III EXP Flow Analyzer Section 5 Figure 5 17 Dropdown menu for exporting log data ...
Page 94: ...88 Section 5 MC III EXP Flow Analyzer ...
Page 105: ...99 MC III EXP Flow Analyzer Section 6 ...
Page 114: ...A 9 MC III EXP Flow Analyzer Appendix A ...
Page 121: ...B 7 MC III EXP Flow Analyzer Appendix B ...
Page 123: ...C 2 Appendix C MC III EXP Flow Analyzer ...
Page 141: ...D 18 Appendix D MC III EXP Flow Analyzer ...
Page 143: ......