D-15
MC-III™ EXP Flow Analyzer
Appendix D
Control Register
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Access
70
0046
Control Register #1
U16
R/W
The Control register allows specific functions to be implemented via the communication port. The following
table shows the value to be written to the control register to implement the desired function.
Code
Function
20000
Transfers the polling total and polling run time
to the previous polling total and previous polling
run time registers, increments the polling index
register, and resets the polling total and polling run
time registers.
30000
Resets grand total
40000
Loads factory defaults
40040
Creates processor reset
Wellsite Parameters
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Access
200
00C8
Company Name [20 characters]
PA
RO
210
00D2
Well Name [20 characters]
PA
RO
220
00DC
Site Location [20 characters]
PA
RO
300
012C
Site ID [20 characters]
PA
RO
310
0136
Tag Name [10 characters]
PA
RO
315
013B
Legal Description [34 characters]
PA
RO
400
0190
Sensor Model Number [20 characters]
PA
RO
410
019A
Sensor Serial Number [20 characters]
PA
RO
420
01A4
Measurement Type [20 characters]
PA
RO
500
01F4
User Note [64 characters]
PA
RO
These registers provide access to the ASCII characters that are used in the Wellsite Information screen of the
software. These registers are read-only; if these parameters need to be changed, the user must use the interface
software program.
Log Data
The MC-III provides Enron Modbus
®
compliant downloads. For detailed instructions on downloading hourly,
daily and event data, refer to
Specifications and Requirements for an Electronic Flow Measurement Remote
Terminal Unit for Enron Corp
. If an Enron host is not available or is too cumbersome to implement, the Enron
records are individually addressed in another Modbus
®
map. Contact Cameron technical support for details.
Summary of Contents for NUFLO MC-III EXP
Page 1: ...NUFLO TM MC III EXP Flow Analyzer User Manual Manual No 9A 50165003 Rev 06 Valves Measurement ...
Page 18: ...12 Section 1 MC III EXP Flow Analyzer ...
Page 35: ...29 MC III EXP Flow Analyzer Section 2 ...
Page 46: ...40 Section 3 MC III EXP Flow Analyzer ...
Page 81: ...75 MC III EXP Flow Analyzer Section 4 ...
Page 93: ...87 MC III EXP Flow Analyzer Section 5 Figure 5 17 Dropdown menu for exporting log data ...
Page 94: ...88 Section 5 MC III EXP Flow Analyzer ...
Page 105: ...99 MC III EXP Flow Analyzer Section 6 ...
Page 114: ...A 9 MC III EXP Flow Analyzer Appendix A ...
Page 121: ...B 7 MC III EXP Flow Analyzer Appendix B ...
Page 123: ...C 2 Appendix C MC III EXP Flow Analyzer ...
Page 141: ...D 18 Appendix D MC III EXP Flow Analyzer ...
Page 143: ......