D-17
MC-III™ EXP Flow Analyzer
Appendix D
Enron Event Record Format
Parameter
Data Type
Status
U16
Address
U16
Time
(HH:MM:SS)
FP32
Date
(MMDDYY)
FP32
As-Found
FP32
As-Left
FP32
The Event Log status is a 16-bit value used to indicate the reset source in the event log. The following table
indicates the reset status.
Reset Status
Status Code
Value
Normal
0
Power-On Reset
3
Watch-Dog
8
Software Reset
16
Flash Memory Error
32
Log Capacity
Log Type
Capacity
Hourly Logs
768
Daily Logs
384
Event Logs
345