D-6
Appendix D
MC-III™ EXP Flow Analyzer
Input Configuration
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Access
Default
2002
07D2
Rate Volume Units
Units
0 = No Units
1 = Gallons
2 = Barrels
3 = Cubic Meters
4 = Cubic Feet
5 = Liters
Units × 1000
16 = No Units
17 = Gallons
18 = Barrels
19 = Cubic Meters
20 = Cubic Feet
21 = Liters
U16
R/W
2
Standard Units
32 = No Units
33 = Gallons
34 = Barrels
35 = Cubic Meters
36 = Cubic Feet
37 = Liters
Std. Units × 1000
48 = No Units
49 = Gallons
50 = Barrels
51 = Cubic Meters
52 = Cubic Feet
53 = Liters
2003
07D3
Rate Time Base
0 = Second
1 = Minute
2 = Hour
3 = Day
U16
R/W
3
2004
07D4
Rate Decimal Point Location
0 = No digits to the right of the decimal point
1 = Tenths
2 = Hundredths
3 = Thousandths
U16
R/W
2
2005
07D5
Calculation Period
(sec)
U16
R/W
4
2006
07D6
Turbine Meter Input Configuration
0 = Pulse Input
1 = TFM - LOW
2 = TFM - MED
3 = TFM - HIGH
U16
R/W
1
2007
07D7
Low Frequency Cut-Off Threshold
(Hz)
U16
2
2008
07D8
Factor Type
1 = 1-Point K-Factor
2 = 2-Point K-Factor
…
12 = 12-Point K-Factor
U16
R/W
1
Summary of Contents for NUFLO MC-III EXP
Page 1: ...NUFLO TM MC III EXP Flow Analyzer User Manual Manual No 9A 50165003 Rev 06 Valves Measurement ...
Page 18: ...12 Section 1 MC III EXP Flow Analyzer ...
Page 35: ...29 MC III EXP Flow Analyzer Section 2 ...
Page 46: ...40 Section 3 MC III EXP Flow Analyzer ...
Page 81: ...75 MC III EXP Flow Analyzer Section 4 ...
Page 93: ...87 MC III EXP Flow Analyzer Section 5 Figure 5 17 Dropdown menu for exporting log data ...
Page 94: ...88 Section 5 MC III EXP Flow Analyzer ...
Page 105: ...99 MC III EXP Flow Analyzer Section 6 ...
Page 114: ...A 9 MC III EXP Flow Analyzer Appendix A ...
Page 121: ...B 7 MC III EXP Flow Analyzer Appendix B ...
Page 123: ...C 2 Appendix C MC III EXP Flow Analyzer ...
Page 141: ...D 18 Appendix D MC III EXP Flow Analyzer ...
Page 143: ......