PTP 450 Configuration and User Guide
Task 4: Configuring General and Unit settings
3-24
pmp-0815 (August 2015)
In the
General
tab of the BHS, you may set the following parameters.
Table 16
BHS General tab attributes
Attribute
Meaning
Timing Mode
Allows the user to choose the mode between Timing Master and
Timing Slave.
Link Speed
From the drop-down list of options, select the type of link speed
for the Ethernet connection. The default for this parameter is that
all speeds are selected. The recommended setting is a single
speed selection for all BHMs and BHSs in the operator network.
Region
This parameter allows you to set the region in which the radio will
operate.
The BHS radio automatically inherits the Region type of the
master. This behavior ignores the value of the
Region
parameter
in the BHS, even when the value is
None
. Nevertheless, since
future system software releases may read the value in order to
configure some other region-sensitive feature(s), this parameter
must be always set to the value that corresponds to the local
region.
Country
This parameter allows you to set the country in which the radio
will operate.
The BHS radio automatically inherits the Country Code type of
the master. This behavior ignores the value of the
Country
parameter in the BHS, even when the value is
None
.
Nevertheless, since future system software releases may read the
value in order to configure some other region-sensitive feature(s),
this parameter must be always set to the value that corresponds
to the local region.
PTP 450 equipment shipped to the United States is locked to a
Region Code setting of “United States”. Units shipped to regions
other than the United States must be configured with the
corresponding Region Code to comply with local regulatory
requirements.
Webpage Auto
Update
Enter the frequency (in seconds) for the web browser to
automatically refresh the web-based interface. The default setting
is
0. The 0 setting causes the web-based interface to never be
automatically refreshed.