Network migration planning
PTP 450 Configuration and User
pmp-0815 (August 2015)
4-9
Table 39
Deployment scenario 2 spectrum usage
Beginning PTP 230
frequency usage
Resulting PTP 450 frequency
usage
5725
5730
5735
5740
OFDM (A)
MIMO (A) 5.740
GHz
5745
5750
OFDM (B)
MIMO (B) 5.750
GHz
5755
5760
OFDM (C)
MIMO (C) 5.760
GHz
5765
5770
Deployment scenario 2 migration procedure
During this procedure, it is assumed that there are no temporary frequencies available and
that the PTP 450 BHMs replaces the existing BHMs.
Procedure 11
Deployment scenario 2 migration procedure
1
Identify proximity to potential system interferers by running a spectrum analysis
scan where the PTP 450 equipment is deployed. It is recommended to run this
scan at several different times of day and night
2
Record relevant BHM and BHS configuration parameters within the current
operating network, if applicable, including:
frequency configuration
data network configuration
RF statistics
encryption
3
Configure the PTP 450 BHM and BHSs for deployment
4
Install the PTP 450 BHM (frequency A)
5
Install the PTP 450 MIMO (frequency A) BHSs – powered on
6
Verify BHS registration, link quality and link performance.
7
Continue installation for frequency B sector and frequency C sector.