background image

 

Installation Guide 

 

PTP 820F 
System Release 10.9 

Summary of Contents for PTP 820F

Page 1: ...i Installation Guide PTP 820F System Release 10 9 ...

Page 2: ... material Accordingly any copyrighted material of Cambium its licensors or the 3rd Party software supplied material contained in the Cambium products described in this document may not be copied reproduced reverse engineered distributed merged or modified in any manner without the express written permission of Cambium Furthermore the purchase of Cambium products shall not be deemed to grant either...

Page 3: ...Countries xi Disposal of Cambium Equipment xi Disposal of Surplus Packaging xi In non EU Countries xi Chapter 1 Before You Start 2 1 Safety Precautions Declared Material 2 1 General Equipment Precautions 2 1 Précautions générales relatives à l équipement 2 2 Allgemeine Vorsichtsmaßnahmen für die Anlage 2 2 Pre installation Instructions 2 4 Packing 2 4 Transportation and Storage 2 4 Unpacking 2 4 I...

Page 4: ...17 Chapter 6 Power Supply Notes 6 19 Chapter 7 IDU RFU Cable Connection 7 20 Chapter 8 Performing Initial Configuration 8 21 Establishing a Connection 8 21 Connecting to the Unit with a Serial Connection 8 21 Connecting to the Unit with a LAN Connection 8 21 Logging On 8 22 Changing Your Password 8 23 Configuration 8 24 Chapter 9 Specifications 9 25 Environmental Specifications for IDU 9 25 Enviro...

Page 5: ... Full Configuration 4 13 Figure 7 Power Supply Grounding 5 17 Figure 8 Correct Wiring of Power Connector 5 18 Figure 9 Connecting the Power Cable 5 18 Figure 10 Terminal Interface 8 21 Figure 11 Management Interface 8 22 Figure 12 Login Window 8 22 Figure 13 Change User Password Page 8 23 Figure 14 Quick Configuration From File Page Error Bookmark not defined Figure 15 Quick Configuration From Fil...

Page 6: ...vi phn 4750_003v006 List of Tables Table 1 2 x FE Splitter Cable Marketing Model 2 8 Table 2 IDU RFU Cable Connection 7 20 Table 3 IDU Mechanical Specifications 9 25 ...

Page 7: ...You Should Know A PTP 820F system consists of an PTP 820F indoor unit IDU and one or more radio frequency units RFUs This manual provides instructions for the installation of the PTP 820F IDU only Some features described in this manual may not be available in the current release Consult the Release Notes for the functionality supported in the specific release you are using Related Documents PTP 82...

Page 8: ...viii phn 4750_003v006 Telephone number list http www cambiumnetworks com support contact support Address Cambium Networks Limited Linhay Business Park Eastern Road Ashburton Devon UK TQ13 7UP ...

Page 9: ...ture content accuracy or completeness of our documents Send feedback to support cambiumnetworks com Problems and Warranty Reporting Problems If any problems are encountered when installing or operating this equipment follow this procedure to investigate and report 1 Search this document and the software release notes of supported releases 2 Visit the support website 3 Ask for assistance from the C...

Page 10: ...recommendations regarding security practices however the implementation of these recommendations and final responsibility for the security of the system lies with the operator of the system Warnings Cautions and Notes The following describes how warnings and cautions are used in this document and in all documents of the Cambium Networks document set Warnings Warnings precede instructions that cont...

Page 11: ...ountries Disposal of Cambium Equipment European Union EU Directive 2002 96 EC Waste Electrical and Electronic Equipment WEEE Do not dispose of Cambium equipment in landfill sites For disposal instructions refer to http www cambiumnetworks com support Disposal of Surplus Packaging Do not dispose of surplus packaging in landfill sites In the EU it is the individual recipient s responsibility to ensu...

Page 12: ...hose specified herein may result in hazardous radiation exposure Caution When working with an RFU S note the following risk of electric shock and energy hazard Disconnecting one power supply disconnects only one power supply module To isolate the unit completely disconnect all power supplies Caution Machine noise information order 3 GPSGV the highest sound pressure level amounts to 70 dB A or less...

Page 13: ... utrustningen och kabel TV nätet Précautions générales relatives à l équipement Caution L utilisation de commandes ou de réglages ou l exécution de procédures autres que celles spécifiées dans les présentes peut engendrer une exposition dangereuse aux rayonnements Caution L usage de RFU S s accompagne du risque suivant d électrocution et de danger électrique le débranchement d une alimentation éle...

Page 14: ...arthing conductor at the equipment Restricted Access Area DC powered equipment should only be installed in a Restricted Access Area Installation Codes The equipment must be installed according to country national electrical codes For North America equipment must be installed in accordance to the US National Electrical Code Articles 110 16 110 17 and 110 18 and the Canadian Electrical Code Section ...

Page 15: ...ted to the installation site in its original packing case If intermediate storage is required the packed equipment must be stored in a dry and cool environment and out of direct sunlight in accordance with ETS 300 019 1 1 Class 1 2 Unpacking The equipment is packed in sealed plastic bags and moisture absorbing bags are inserted Any separate sensitive product i e printed boards are packed in anti s...

Page 16: ...acking lists and ensure that correct parts numbers quantities of goods have arrived Inspect for any damage on the cases and equipment Please report any damage or discrepancy to Cambium Networks support by e mailing to support cambiumnetworks com ...

Page 17: ...terfaces Two dual mode GbE or cascading combo interfaces Two combo RJ 45 or SFP radio interfaces An additional interface that can be configured as a combo RJ 45 or SFP radio interface or a 1 GbE interface For TDM traffic a PTP 820F IDU includes a 16 x E1 DS1 interface and two STM 1 OC 3 interfaces that require the addition of an optional rear mounted STM 1 OC 3 module The STM 1 OC 3 interfaces can...

Page 18: ...rnet interfaces or one Ethernet interface and one radio interface RFU3 SFP5 and RFU3 2 5GE5 A combo interface that can be used as either an SFP or RJ 45 RFU interface or an SFP or RJ 45 Ethernet interface SFP6 2 5GE6 A combo interface SFP or RJ 45 for Ethernet Figure 3 RFU3 SFP5 6 Interfaces Ethernet Management Interfaces PTP 820F contains two FE management interfaces which connect to a single RJ ...

Page 19: ...gement E1 DS1 Interface PTP 820F includes an MDR69 connector in which 16 E1 interfaces are available ports 1 through 16 STM 1 OC 3 Interfaces The PTP 820F includes two ch STM 1 OC 3 ports which can be used as a 1 1 STM 1 OC 3 protection configuration The STM 1 OC 3 port provides an interface for up to 63 E1 or 84 DS1 lines inside a standard channelized STM 1 or OC 3 signal Each E1 DS1 line is tran...

Page 20: ...e RS 232 A local craft terminal can be connected to the terminal interface for local CLI management of the unit External Alarms PTP 820F includes a DB9 dry contact external alarms interface The external alarms interface supports five input alarms and a single output alarm The input alarms are configurable according to 1 Intermediate 2 Critical 3 Major 4 Minor 5 Warning The output alarm is configur...

Page 21: ...2 10 phn 4750_003v006 Figure 5 SM Card and Cover ...

Page 22: ...um representative by e mail or fax Unpacking Equipment at the Site The equipment is packed in sealed plastic bags and moisture absorbing bags are inserted Any separate sensitive product i e printed boards are packed in anti static handling bags The equipment is further packed in special designed cases Marking is done according to standard practice unless otherwise specified by customers Customers ...

Page 23: ...ressly approved by Cambium Networks could void the user s authority to operate the equipment Where special cables shields adapters and grounding kits are supplied or described in this manual these items must be used to comply with the relevant regulations ...

Page 24: ... Required to Perform the Installation Description Quantity PTP 820F chassis 1 19 rack sub rack 1 SM Card Cover 1 Tools Philips screwdriver Flat screwdriver Installing the PTP 820F IDU in the Rack 19 Insert and hold the PTP 820F IDU in the rack as shown in the following figures Use four screws not supplied with the installation kit to fasten the IDU to the rack ...

Page 25: ...figure below This restriction also applies to PTP 820F units installed in proximity with third party units Grounding the PTP 820F Connect a grounding wire first to the single point stud shown in the figure below and then to the rack using a single screw and two washers Verify that the grounding resistance is 0 2 ohms Note The grounding wire must be 16 AWG or thicker ...

Page 26: ...w IDU The SM Card holds the configuration and software for the IDU The SM Card is embedded in the SM Card plastic cover that is located under the SM card aluminum cover To remove the SM Card 1 Switch the unit power off 2 Loosen the 2 screws of the SM Card s aluminum cover and remove it from the IDU 3 Loosen the 2 screws of the SM Card Plastic Cover and gently remove it from the IDU ...

Page 27: ...SM Card the old IDU make sure that there is no foreign matter blocking the sockets in the opening where the SM Card is installed 5 Gently place the SM Card in its place and tighten the 2 screws 6 Place the SM Card s aluminum cover in its place and tighten the 2 screws ...

Page 28: ...r is included with the PTP 820F unit To connect a power cable to the PTP 820F 1 Expose the wires of the power cable 2 Loosen the top two screws on the connector 3 Verify that the wiring is according to the correct polarity Note Before connecting the power supply to the PTP 820F unit you must verify that the positive pole in the external power supply is grounded Power supply grounding should be in ...

Page 29: ...or 4 Insert the wires into the connector 5 Secure the wires in the connector with the screws 6 Plug the connector into the PTP 820F power interface and tighten the two screws on the sides of the connector to secure the connector Figure 9 Connecting the Power Cable ...

Page 30: ...ly connection Remove all power from the unit for servicing Note Make sure to use a circuit breaker to protect the circuit from damage by short or overload In a building installation the circuit breaker shall be readily accessible and incorporated external to the equipment The maximum rating of the overcurrent protection shall be 10 Amp while the maximum current rating is 6 5A 40V in when operating...

Page 31: ...r to the User Guide for PTP 820F PTP 820G For an RFU D or RFU S connecting to an optical RFU interface and for an RFU D HP connecting to either an electrical or an optical RFU interface an external DC power cable is required to supply power to the RFU Table 2 IDU RFU Cable Connection RFU Interface Cable Type Maximum Length 6 11 GHz 13 42 GHz RFU D Optical Fiber 300m Electrical CAT 5e 24 AWG 65m 10...

Page 32: ...t an RS 232 cable with an RJ 45 interface from your laptop or PC to the Terminal Interface on the PTP 820F front panel Figure 10 Terminal Interface 2 Configure the following settings for the COM port you are using on your PC or laptop o Bits per Second 115 200 o Data Bits 8 o Parity None o Stop Bits 1 o Flow Control None Connecting to the Unit with a LAN Connection PTP 820F contains two FE managem...

Page 33: ...2 Click Change adapter settings 3 Select Local Area Connection Properties Internet Protocol Version 4 TCP IP o IP address 192 168 1 10 o Subnet mask 255 255 255 0 o No default gateway 4 Press OK to apply the settings Logging On 1 Open an Internet browser Internet Explorer or Mozilla Firefox 2 Type in the default IP address 192 168 1 1 in the Address Bar Figure 12 Login Window 3 Enter the following...

Page 34: ...e following criteria o Password length must be at least eight characters o Password must include characters of at least three of the following character types lower case letters upper case letters digits and special characters For purposes of meeting this requirement upper case letters at the beginning of the password and digits at the end of the password are not counted o The last five passwords ...

Page 35: ...255 255 255 0 In addition to setting the IP addresses the following configuration steps should be performed to establish basic connectivity For a detailed description of these procedures refer to the User Guide for PTP 820F and PTP 820G Enable the Radio Interfaces Set the Radio Frequencies Configure the License Unmute the Radio Note After the new IP address is set the contact with the element will...

Page 36: ...imited margins Humidity 5 RH to 95 RH Environmental Specifications for RFU Operating ETSI EN 300 019 1 4 Class 4 1 Temperature o 33 C 27F to 55 C 131F Temperature range for continuous operating temperature with high reliability o 45 C 49F to 60 C 140F Temperature range for exceptional temperatures tested successfully with limited margins Humidity 5 RH to 100 RH Mechanical Specifications Table 3 ID...

Page 37: ...ta and the DC power required for the RFU For an RFU S or RFU D connecting to an SFP RFU interface and for an RFU D HP connecting to either an RJ 45 or an SFP RFU interface an external DC power cable is required to supply power to the RFU Power Consumption Specifications The following table shows the maximum power consumption for PTP 820F IDU and supported RFUs The maximum power consumption for the...

Page 38: ...uirements of the site at which the products were installed The commissioning tests cover the required configuration information that should be recorded and the tests that should be performed on the radio link Site Acceptance Procedure The purpose of the following procedures is to verify that all installation requirements were noted and checked Following this procedure will ensure proper long lasti...

Page 39: ...d OK Antenna Launch unit polarization is as per link requirements OK 4 RADIO FREQUENCY UNIT RFU Type of RFU mount Direct or Remote mount RFU is securely mounted to the antenna or pole OK RFU is grounded as per installation instructions OK RFU s polarization is as per link requirements OK RFU is installed properly and has no physical damage OK For Remote Mount Only Remote mount kit is securely moun...

Page 40: ...6 FLEXIBLE WAVEGUIDE Overall flexible WG length Flexible WG type Flexible WG is connected securely to RFU and Antenna OK Flexible WG connector is weather proofed sealed at the RFU OK At the RFU the flexible WG has a service drip loop to prevent moisture from entering the connector OK Flexible WG is secured using suitable restraints to fixed points at regular intervals 0 5 m recommended OK Flexible...

Page 41: ...3 Ampere per carrier Power Supply is properly grounded OK DC power backup type IDU DC connector is secure and the DC input leads are correctly terminated no bare wires are visible OK IDU DC connector and GND leads are shorted and GND is grounded OK 9 RACK INSTALLATION Rack is mounted to the shelter floor with four screws OK Rack is mounted to the shelter wall with two screws OK 10 REMARKS NOTES 11...

Page 42: ...vent corrosion 2 Antenna Antenna is grounded as per site specifications See the third point in the Antenna Mounting section above Antenna sway braces are fitted and installed correctly where applicable Typically for an antenna of 1 2 m or larger an extra sway brace is fitted to the mounting frame of the antenna This sway brace should not be mounted to the same pole as the antenna but should be ins...

Page 43: ...rking with ATPC ATPC is operating as expected RSL reference level Ethernet Line Interfaces Test Connect Ethernet Packet Analyzer to the GbE port Use physical loop at remote end or connect second analyzer Run Packet Loss test for at least one hour load rate as per Cambium s specifications for the chosen MRMC Connect Ethernet Packet Analyzer to the FE port Use physical loop at remote end or connect ...

Page 44: ...ts Maintaining the Commissioning Log is important for tracking your installations and to provide essential data for Cambium Networks Upon completing the Commissioning Log send the log to Cambium support center at support cambiumnetworks com PTP 820 LINK COMMISSIONING LOG 1 GENERAL INFORMATION Customer Radio model Configuration Radio link code Site 1 name add Site 2 name add 2 RFU Site 1 Site 2 RFU...

Page 45: ...ype Mounting losses 4 LINK PARAMETERS Site 1 Site 2 Link distance Rain zone Expected RSL dBm Expected Diversity RSL dBm RSL Main dBm RSL Diversity dBm Deviation from exp RSL 4 dB 5 COMMISSIONING TESTS Site 1 Site 2 Line loopback Pass Pass RFU loopback Pass Pass Radio BER Pass Pass FE test Pass Pass GbE test Pass Pass 6 MANAGEMENT CONFIGURATION Site 1 Site 2 Eth IP Address Eth IP mask ...

Page 46: ...5 phn 4750_003v006 PTP 820 LINK COMMISSIONING LOG Default router In band VLAN 7 REMARKS NOTES 8 INSTALLATION INFORMATION Installed by Name Company Date Signature Commissioned by Name Company Date Signature ...