10-29
phn-4750_003v006
SITE ACCEPTANCE CHECKLIST
Cable connected securely to RFU and IDU
OK
Cable connector is weather-proofed (sealed) at the RFU
OK
At the RFU, cable has a service/drip loop to prevent moisture from
entering the connector
OK
Cable is secured using suitable restraints to fixed points at regular intervals
(0.5 m recommended)
OK
Cable has no sharp bends, kinks, or crushed areas. All bends are per
manufacturer specifications
OK
Grounding/lightning protection is as per site specifications
OK
Lightning protection type and model:
Cable point-of-entry to building/shelter is weather-proof
OK
Cable ends are properly labeled
OK
6. FLEXIBLE WAVEGUIDE
Overall flexible WG length:
Flexible WG type:
Flexible WG is connected securely to RFU and Antenna
OK
Flexible WG connector is weather-proofed (sealed) at the RFU
OK
At the RFU, the flexible WG has a service/drip loop to prevent moisture
from entering the connector
OK
Flexible WG is secured using suitable restraints to fixed points at regular
intervals (0.5 m recommended)
OK
Flexible WG has no sharp bends, kinks, or crushed areas. All bends are per
manufacturer specifications
OK
Flexible WG point-of-entry to building/shelter is weather-proof
OK
Flexible WG ends are properly labeled
OK
7. INDOOR UNIT
IDU is securely mounted to the rack
OK
IDU is located in a properly ventilated environment
OK
IDU fans are functional and air flow to the fans is not disrupted
OK
IDU and rack are grounded as per site specifications
OK