9-25
phn-4750_003v006
Chapter 9
Specifications
Environmental Specifications for IDU
•
Operating: ETSI EN 300 019-1-3 Class 3.2
•
Temperature:
o
-5 °C (23 F) to 55 °C (131 F) - Temperature range for continuous operating temperature with
high reliability.
o
-25 °C (-13 F) to 65 °C (149 F) - Temperature range for exceptional temperatures, tested
successfully, with limited margins.
•
Humidity: 5%RH to 95%RH
Environmental Specifications for RFU
•
Operating: ETSI EN 300 019-1-4 Class 4.1
•
Temperature:
o
-33°C (-27F) to +55°C (131F) – Temperature range for continuous operating temperature
with high reliability:
o
-45°C (-49F) to +60°C (140F) – Temperature range for exceptional temperatures; tested
successfully, with limited margins.
•
Humidity: 5%RH to 100%RH
Mechanical Specifications
Table 3: IDU Mechanical Specifications
IDU Dimensions
Height: 44 mm
Width: 482 mm
Depth: 165 mm
Weight: 2.4 kg
Note
Cold startup requires at least -5°C (23F).