NG,NGL,NGX Rev. 7 - Operating Instructions

EN

5. TRANSPORTATION AND HANDLING

 

The product is packed to maintain the content intact. 
During transportation avoid to stack excessive weights. 
Ensure that during the transportation the box cannot 
move. 
It is not necessary to use any special vehicle to transport 
the packaged device. 
The transport vehicles must comply, for the weight and 
dimensions, with the chosen product (see technical cata-
logue dimensions and weights). 
 

5.1 Handling 

 

Handle with care, the packages must not receive 
impacts. 
Avoid to impact onto the package materials that could 
damage the pump. 
If the weight exceeds 25 Kg the package must be hand-
led by two person at the same time (see technical catalo-
gue). 
 

6 INSTALLATION

 

6.1 Dimensions 

For the dimensions of the device (see technical catalo-
gue dimensions and weights). 
 

6.2 Ambient requirements and installation site 

dimensions 

The customer has to prepare the installation site in order 
to guarantee the right installation and in order to fulfill the 
device requirements (electrical supply, etc...). 
The place where the device will be installed must fulfill the 
requirements in the paragraph 3.2. 
It's Absolutely forbidden to install the machine in an 
environment with potentially explosive atmosphere. 
 

6.3 Unpacking 

 Inspect the device in order to check any damages 

which may have occurred during transportation. 

 

Package material, once removed, must be 
discarded/recycled according to local laws of the destina-
tion country. 
 

6.4. Installation

 

The pumps must be installed with the rotor axis in the hori-
zontal position and with the feet under the pump. 
Provide enough clearance around the unit for 

motor 

ventilation

 and for filling and draining the pump. 

6.4.1. Pipes 

Ensure the insides of pipes are clean and unobstructed 
before connection. 

ATTENTION: The pipes connected to the pump 
should be secured to rest clamps so that they do not 
transmit stress, strain or vibrations to the pump (

par. 

12.1 

fig. 4).  

Tighten  the  pipes  or  union  coupling  to  the  extent 
sufficient to ensure a tight seal. 
Excessive torque may cause damage to the pump. 
When the pipe or union coupling is mounted, keep the 
pump casing connection blocked with a second wrench, 
making sure the connection is not deformed by 
excessive tightening. 
The pipe diameters must not be smaller than the pump 
connections. 
 

6.4.2. Suction pipe 

For capacities over 4 m

3

/h use a suction pipe G 1 1/4 (DN 

32). 

The suction pipe must be perfectly airtight.

 

With  a 

pump  located  above  the water level 

(suction 

lift operation,

 

par. 12.1 

fig. 1, fig. 3

) fit a foot valve with 

strainer (which must always remain immersed) or a 

check valve on the suction connection. 
If operating with 

flexible hoses 

use a semi rigid suction 

hose, in order to avoid the hose narrowing due to suction 
vacuum. 
With the 

liquid  level on the suction side above the 

pump 

(inflow under positive suction head, par. 12.1 

fig. 

2

) fit an inlet gate valve. 

Follow local specifications if increasing network pressure. 

Install  a strainer on the suction side of the pump to 
prevent foreign particles from entering the pump. 

 

6.4.3. Delivery pipe 

Fit a gate valve in the delivery pipe to adjust delivery and 
head. 
Install a pressure gauge. 
 

6.5 Electrical connection 

 

 

 

 
 

 Electrical connection must be carried out only by 

a qualified electrician in accordance with local 
regulations. 

Follow all safety standards. 
The unit must be properly earthed (grounded). 

Connect  the  earthing  (grounding)  conductor  to the  ter-
minal  with  the 

 marking.  

Compare  the frequency and mains voltage with the 
name-plate data and connect the supply conductors to 
the terminals in accordance with the appropriate diagram 
inside the terminal box cover. 

 

ATTENTION:  never  allow  washers  or  other 
metal parts to fall into the internal cable opening 
between the terminal box and stator. 

If  this 

occurs,  dismantle the motor to  recover the object 
which has fallen inside. 

If the terminal box is provided with an inlet gland, use a 
flexible power supply cord of the H07 RN-F type with 
section of cable  not less than (par. 12.3 TAB 1). 
If the terminal box is provided with an inlet bushing, con-
nect the power supply cord through a conduit. 
For use in swimming pools (not when persons are in the 
pool), garden ponds and similar places, a 

residual cur-

rent device 

with I

Δ

N not exceeding 30 mA must be 

installed in the supply circuit. 
Install a 

device for disconnection from the mains

 

(switch) with a contact separation of at least 3 mm in all 
poles. 
With  a  three-phase  motor install an overload protection 
device with curve D appropriate for the rated current of 
the pump. 

Single-phase  NGM, NGXM, NGLM,

 are supplied with a 

capacitor connected to the terminals and (for 220-240 V - 
50 Hz) with an incorporated thermal protector. 
 

7 STARTUP AND OPERATION 
7.1 Preliminary checks before start-up of the pump 

Do not start-up the device in case of damaged parts. 

 
7.2 First starting 

 

 

 

 
 
 

ATTENTION: never run the pump dry. 

Start the pump 

after filling it completely with liquid. 

When the pump is located above the water level

 (suc-

tion lift operation, par. 12.1

 fig. 1, fig. 3

) or with a positi-

ve suction head which is too low (less than 1 m) to open 
the non-return valve, fill the pump through the priming 
hole (par. 12.1 

fig. 5

). 

OFF

i

OFF

IST NG_NGX_NGL REV7 05_2021.qxp_MXS 11_03con gall  24/05/21  09:58  Pagina 9

Summary of Contents for NG

Page 1: ...oblock sj lv evakuerande jet pump med inbyggd ejektor Close coupled zelfaanzuigende jetpompen met ingebouwde venturi jet NG NGX NGL ISTRUZIONI ORIGINALI PER L USO Pagina 2 Italiano OPERATING INSTRUCTI...

Page 2: ...vono essere rispettate altrimenti sono causa di danneggiamenti all apparecchio o compromettono la sicurezza del personale Informazioni ed avvertenze di carattere elettrico il cui mancato rispetto pu d...

Page 3: ...erse da quelle indicate in targa e nelle presenti istruzioni Rispettare la cadenza degli interventi di manutenzione e la tempestiva sostituzione dei pezzi danneggiati o usurati permette all apparecchi...

Page 4: ...e in aspira zione Con il livello dell acqua in aspirazione sopra la pompa funzionamento sotto battente cap 12 1 fig 2 inserire una saracinesca Per aumentare la pressione della rete di distribuzione os...

Page 5: ...empimento 7 6 Regolatore automatico IDROMAT fornibile a richiesta Comanda automaticamente l avviamento della pompa all aper tura degli utilizzi e l arresto alla chiusura Protegge la pompa contro il fu...

Page 6: ...one c Pulire o sostituire la valvola di fondo e impiegare un tubo di aspirazione idoneo d Pulire il filtro se necessario sostituirlo Vedere anche punto 2b a Usare tubi e accessori idonei all impiego b...

Page 7: ...le chapter 6 5 The type of electrical protection to be installed chapter 6 5 1 1 Symbols To improve the understanding of the manual below are indicated the symbols used with the related meaning Inform...

Page 8: ...ing instructions and the indications defined for the different steps from transportation to disposal The specialized technicians must carefully comply with all applicable standards and laws including...

Page 9: ...1 fig 3 fit a foot valve with strainer which must always remain immersed or a check valve on the suction connection If operating with flexible hoses use a semi rigid suction hose in order to avoid th...

Page 10: ...temperatu re is higher than 80 C Wait until the water has cooled inside the pump before starting again or opening the draining and filling plugs 7 6 Automatic regulator IDROMAT can be supplied on requ...

Page 11: ...oot valve blocked or suction pipe not fully immersed in liquid 3d Suction filter blocked 4a Pipes and accessories with diameter too small 4b Presence of deposits or solid bodies in the impeller 4c Rot...

Page 12: ...arlegt Den maximale zul ssigen Geh useenddruck Kapitel 3 1 Typ und Querschnitt des Anschlusskabels Kapitel 6 5 Den Typ der zu installierenden elektri schen Absicherung Kapitel 6 5 1 1 Verwendete Symbo...

Page 13: ...se sorgf ltig durchzulesen Lesen und beachten Sie alle technische Anweisungen Betriebsanleitungen und Hinweise ber s mtliche Arbeitsphasen vom Transport bis zur endg ltigen Entsorgung welche in diesem...

Page 14: ...ten du rfen nicht kleiner als die Pumpenstutzen sein 6 4 2 Saugleitung Fu r F rderstr me u ber 4 m3 h ist eine Saugleitung G 1 1 4 DN 32 zu verwenden Die Saugleitung mu unbedingt luftdicht sein Bei In...

Page 15: ...trieb mit geschlossener Druckleitungs ffnung f hrt zum Bruch bzw Besch digung von Pumpenteilen siehe Kapitel 7 6 Wenn das Wasser wegen l ngeren Betriebs gegen geschlossenen Absperrschieber berhitzt is...

Page 16: ...Siehe auch Punkt 2b a Verwenden Sie Verrohrung und Armaturen entsprechend Ihrer Anwendung b Reinigen Sie das Laufrad und bauen Sie einen Ansaugfilter ein c Ersetzen Sie das Laufrad d Laufrad und Pumpe...

Page 17: ...ompe chapitre 3 1 Le type et la section du c ble d alimen tation chapitre 6 5 Le type de protection lectrique instal ler chapitre 6 5 1 1 Pictogrammes utilis s Pour une compr hension plus facile les s...

Page 18: ...ons techniques de fonctionnement doivent tre lues et observ es correctement ainsi que les indications donn es dans le manuel selon les diff rents passages du transport au d mant lement final Les techn...

Page 19: ...ices de la pompe 6 4 2 Tuyau d aspiration Pour d bits sup rieurs 4 m3 h utiliser un tuyau d aspira tion G 1 1 4 DN 32 Le tuyau d aspiration doit tre parfaitement tanche Avec la pompe au dessus du nive...

Page 20: ...eau est surchauff e pour le fonctionnement pro long avec orifice ferm arr ter la pompe avant d ouvrir la vanne Ne pas toucher le fluide quand sa temp rature est sup rieure 60 C Ne pas toucher la pomp...

Page 21: ...accessoires avec un diam tre trop petit b Pr sence de d p ts et de corps trangers dans la roue c Rotor d terior d Rotor et corps de pompe us s e Gaz dissous dans l eau f Viscosit du liquide pomp g Se...

Page 22: ...tipo de protecci n el ctrica que se instalar el Cap tulo 6 5 1 1 S mbolos utilizados Para mejorar la comprensi n se utilizan los s mbolos picto gramas a continuaci n con sus significados Informaci n...

Page 23: ...r toda informaci n sobre la seguridad Es necesario leer cuidadosamente y seguir las instrucciones t cnicas de funcionamiento y las indicaciones aqu contenidas para los diferentes pasos del transporte...

Page 24: ...m3 h utilizar un tubo de aspiraci n G 1 1 4 DN 32 La tuber a de aspiraci n debe poseer una perfecta estan queidad Con la bomba por encima del nivel del agua funcio namiento en aspiraci n cap 12 1 fig...

Page 25: ...agua El funcionamiento prolongado con la boca de impulsi n cerrada lleva a la rotura o al da o de partes de la bomba ver cap tulo 7 6 Cuando el agua sufre un aumento de temperatura por funcionamiento...

Page 26: ...el punto 2b a Utilizar una tuber a y accesorios id neas a la utilizaci n b Limpiar el rodete e instalar un filtro en aspiraci n c Sustituir el rodete d Sustituir el rodete y el cuerpo de bomba e Abrir...

Page 27: ...tel 6 5 Typ av elektriska skydd som ska installeras kapitel 6 5 1 1 Symboler som anv nds F r att underl tta f rst elsen anv nds de symboler piktogram som indikeras nedan med respektive betydelser Info...

Page 28: ...igenom och f lj alla tekniska instruktioner funktionsanvisningar och indikationer som finns i denna handbok f r de olika skedena allt fr n transport till slutlig kassering De specialutbildade teknike...

Page 29: ...ngar anv ndes h ll emot vid tdragning med ett andra verktyg f r att ej deformera pumphuset R rdiametrarna f r aldrig understiga pumpens anslut ningsdimensioner 6 4 2 Sugledning F r kapaciteter ver 4 m...

Page 30: ...set se avsnitt 7 6 Om pumpen blivit verhettad genom att k rning mot st ngd ventil f rekommit under en l ngre tid skall pum pen stoppas f re ventilen ppnas F rsiktighet m ste iakttagas n r v tsketemper...

Page 31: ...pumphjulet och montera ett filter i inloppet c Byt ut pumphjulet d Byt ut pumphjulet och pumphuset e Utf r man vrarna f r ppning och st ngning av ventilen i utloppet f Pumpen r ej anpassad v tskan g...

Page 32: ...ing skabel hoofdstuk 6 5 Het type en het gedeelte over montage van de electrische beveiliging hoofdstuk 6 5 1 1 Gebruikte symbolen Voor een beter begrip zijn de onderstaande symbolen pic togrammen met...

Page 33: ...dsaanwijzingen te kennen Alle technische instructies voor het functioneren en de aanwijzingen voor de diverse passages van het transport tot aan de definitieve afvoer die hier zijn gegeven moeten aan...

Page 34: ...aandraaien van koppelingen dient u het pomphuis vast te houden met een tweede sleutel Verzeker u ervan dat de aansluiting niet beschadigt door overmatig hard aandraaien De leidingdiameters mogen niet...

Page 35: ...leiding of aftapplug gen te openen 7 6 Automatische pompschakelaar IDROMAT wordt geleverd op verzoek Voor automatisch starten stoppen van de pomp wanneer aftappunten worden geopend gesloten Voor besch...

Page 36: ...f indien noodzakelijk vervang het filter Zie punt 2b a Gebruik de juiste diameter zuig en persleidingen en aansluitdelen voor deze toepassing b Maak de waaier schoon en installeer een filter in de zui...

Page 37: ...8 40 9 41 10 41 11 41 12 52 12 1 52 12 2 54 58 1 Calpeda SpA 2 3 8 3 1 6 5 6 5 1 1 E E 1 2 Calpeda S p A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 1 4 i i OFF O...

Page 38: ...i XXXXXXX Q min max X X m3 h IEC 60034 1 IECX X AAAAXXXXX XXX XXX XXX H max min X X m ESCC2900 MEI XX XX kg IP XX n XXXX min V XXX XXX XXX XXX XXX XXX cos XXX XXX XXX 230 400Y V3 50Hz XX F X X A XXXXX...

Page 39: ...6 6 1 6 2 3 2 6 3 6 4 vx 6 4 1 12 1 4 6 4 2 4 m3 h G 11 4 D 32 12 1 1 3 12 1 2 6 4 3 6 5 L 07 RN F 12 3 TAB 1 30mA 3 mm D NGM NGXM NGLM 220 240V 7 7 1 7 2 OFF i OFF IST NG_NGX_NGL REV7 05_2021 qxp_MXS...

Page 40: ...7 GR 1 3 1m 5 2 7 3 0 5 m 1 m NG 12 1 1 LN 12 1 1 7 4 7 5 7 6 60 C 80 C a o 7 6 IDROMAT 12 1 2 7 7 OFF 6 5 8 CALPEDA SpA CALPEDA SpA 8 1 ON i i OFF IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24...

Page 41: ...12 19 EU WEEE 10 10 1 CALPEDA S p A OFF OFF 11 OFF 1 2 3 4 5 6 a b c d e f a b c a b c d a b c d e f g a b a b c d a b c d a c e f a b c a b c d 2b a b c d e f g a b a b c a b c d 6a 6b 6c IST NG_NGX_...

Page 42: ...9 46 10 46 11 46 12 52 12 1 52 12 2 54 12 3 57 58 1 Calpeda S p A 2 3 CE 8 3 1 6 5 6 5 1 1 1 2 Calpeda S p A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 1 4 i OFF...

Page 43: ...Q min max X X m3 h IEC 60034 1 IECX X AAAAXXXXX XXX XXX XXX H max min X X m ESCC2900 MEI XX XX kg IP XX n XXXX min V XXX XXX XXX XXX XXX XXX cos XXX XXX XXX 230 400Y V3 50Hz XX F X X A XXXXXXXX S1 l c...

Page 44: ...1 25 6 6 1 6 2 3 2 6 3 6 4 6 4 1 12 1 4 6 4 2 4 G 1 1 4 DN 32 12 1 1 3 12 1 2 6 4 3 6 5 07 RN F 12 3 TAB 1 I N 30 mA 3 D NGM NGXM NGLM 50 220 240 7 7 1 OFF i IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03c...

Page 45: ...7 RU 7 2 12 1 1 3 1 12 1 5 12 1 2 7 3 0 5 1 NG 12 1 1 12 1 1 7 4 7 5 5 7 6 60 80 7 6 IDROMAT 12 1 2 7 7 6 5 8 Calpeda S p A Calpeda S p A i i ON OFF IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 2...

Page 46: ...Rev 7 RU 11 OFF 1 2 3 4 5 6 a a a a a a C a 2 a a 6 6 6 8 1 12 1 6 8 2 8 3 IP55 IP55 LOCTITE 510 9 2012 19 EU WEEE 10 10 1 Calpeda S p A OFF OFF IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24 05...

Page 47: ...50 10 50 11 51 12 52 12 1 52 12 2 54 12 3 57 58 1 CALPEDA S P A 2 3 CE 8 3 1 6 5 6 5 1 1 1 2 CALPEDA S P A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 1 4 i i OFF...

Page 48: ...XXXX Q min max X X m3 h IEC 60034 1 IECX X AAAAXXXXX XXX XXX XXX H max min X X m ESCC2900 MEI XX XX kg IP XX n XXXX min V XXX XXX XXX XXX XXX XXX cos XXX XXX XXX 230 400Y V3 50Hz XX F X X A XXXXXXXX S...

Page 49: ...6 3 6 4 6 4 1 12 1 4 6 4 2 4m3 h G1 1 4 DN32 12 1 1 3 12 1 2 6 4 3 _ 6 5 H07RN F 12 3 30 3mm D NGM NGXM NGLM 220 240V 50Hz 7 7 1 7 2 12 1 1 3 1m 12 1 5 12 1 2 7 3 OFF OFF i IST NG_NGX_NGL REV7 05_2021...

Page 50: ...4 7 5 5 60 80 7 6 IDROMAT 12 1 2 7 7 6 5 8 CALPEDA CALPEDA S P A 8 1 6 8 2 8 3 IP 55 IP 55 LOCTITE 510 9 WEEE 2012 19 EU 10 10 1 CALPEDA S P A OFF OFF OFF i i ON IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11...

Page 51: ...c 1d 1e 1f 2a 2b 3c 3a 3b 3c 3d 4a 4b 4c 4d 4e 4f 4g 5a 5b 6a 6b 6c 6d 1a 1b 1c 1d a c 1e 2 1f 2a 2b 2c 3a 3b 3c 3d 2b 4a 4b 4c 4d 4e 4f 4g 5a 5b 6a 6b 6c 6a 6b 6c 6d 6a 6b 6c IST NG_NGX_NGL REV7 05_2...

Page 52: ...unzionamento sotto battente Positive suction head operation Zulaufbetrieb Fonctionnement en charge Funcionamiento bajo carga Tillrinning sugsidan Toeloopsituatie Fig 3 Funzionamento in aspirazione Suc...

Page 53: ...ione Installation examples Einbaubeispiele Exemples d installation Ejemplos de instalaciones Installationsexempel Installatievoorbeelden Fig 4 Sostegni ed ancoraggi delle tubazioni Supports and clamps...

Page 54: ...76 04 76 00 90 04 76 54 98 04 98 00 98 08 NGX NGXM 94 02 94 00 76 54 28 20 1 90 00 88 00 92 00 82 00 82 00 76 20 76 16 82 04 81 00 78 00 73 00 14 04 14 06 22 12 22 16 28 04 28 12 36 52 14 20 26 06 46...

Page 55: ...ntaje Ritning f r demontering och montering Onderdelentekening NGL 76 04 76 00 90 04 76 54 98 04 98 00 98 08 NGL NGLM 94 02 94 00 76 54 28 20 1 90 00 88 00 92 00 82 00 82 04 81 00 78 00 73 00 22 12 22...

Page 56: ...6 00 28 00 32 00 14 20 26 00 94 02 98 04 82 00 3 94 116 90 00 82 04 88 00 26 02 14 46 14 04 22 00 22 12 14 12 22 08 22 04 36 54 3 94 116 1 B NG 6 92 00 76 00 78 00 36 00 28 20 73 00 14 24 14 00 28 04...

Page 57: ...Corrente nominale dell apparecchio Rated current of appliance Bemessungsstrom des Gerates Courant nominal de l appareil Corriente nominal del aparato Enhetens nominella str m Dimensiestroom van appara...

Page 58: ...ulations 2016 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 The Ecodesign for Energy Related Products and Energy Information Amendm...

Page 59: ...30 EU 2014 35 EU og er i overensstemmelse med de heri indeholdte standarder Kommissionens forordning nr 2019 1781 D F E DK CALPEDA S p A intygar att pumpar NG NGM NGL NGLM NGX NGXM pumptyp och serienu...

Page 60: ...60 64 NG NGL NGX Rev 7 IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24 05 21 09 59 Pagina 60...

Page 61: ...61 64 NG NGL NGX Rev 7 IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24 05 21 09 59 Pagina 61...

Page 62: ...62 64 NG NGL NGX Rev 7 IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24 05 21 09 59 Pagina 62...

Page 63: ...63 64 NG NGL NGX Rev 7 IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24 05 21 09 59 Pagina 63...

Page 64: ...da s p a Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia Tel 39 0444 476476 E mail info calpeda it www calpeda com IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24 05 21 09 59 Pagin...

Reviews: