NG,NGL,NGX Rev. 7 - Operating Instructions

EN

When the liquid level on the suction side is above 
the pump

 (inflow under positive  suction head, 

fig. 2

), fill 

the pump by opening the suction gate valve slowly and 
completely, keeping the delivery gate valve open to 
release the air. 
Before starting, check that the shaft turns by hand. For 
this purpose use the screwdriver notch on the shaft end 
on the ventilation side. 

When starting, with a three-phase motor, check

 that 

the direction of rotation 

is as shown by the arrows on 

the lantern bracket: clockwise when viewing the motor 
from the fan end.  
Otherwise, disconnect electrical power and reverse the 
connections of two phases. 

7.3. Self-priming 

(Capability  to  clear  the  air  in  the  suction  pipe  when 
starting with the 

pump located above the water level

). 

Conditions for self-priming: 

• suction pipe with connections perfectly airtight and pro-

perly immersed in the water to be lifted; 

• allow 0,5 m (1 m for NG) minimum of straight vertical 

pipe above the discharge port  (par. 12.1 

fig. 1

); 

pump  casing completely filled with clean cold 
water  berfore starting.  

The  pump  is  not self-priming with liquids containing 
oil, alcohol or foaming substances. 

The check valve (par. 12.1 

fig. 1

) prevents reverse 

siphoning through the pump when the pump is stopped 
and retains water in the pump for the next start. 

Without a foot valve or a check valve on the suction 
connection

 

the filling operation must be repeated 

before each start-up.

 

ATTENTION: avoid a prolonged operation with   
unprimed  pump, without  water delivery from the 
completely opened outlet. 

If necessary, repeat the priming operation after the pump 
has been first emptied and then completely filled with 
clean cold water. 
 

7.4. Gate valve regulation 
With the gate valve completely open or with an outlet 
pressure lower than the minimum pressure shown 
on the name-plate, the pump may be noisy. To redu-
ce noise regulate the delivery gate valve. 

7.5. Abnormal operation 

 

Never run the pump for more than five 
minutes with a closed gate valve.  

 

Prolonged operation without a change of water in the 
pump causes dangerous increases of temperature and 
pressure. 
Prolunged operation with a closed delivery port   causes 
breakage or damage to parts of the pump (see 

section 

6.2.

). 

When the water is overheated due to prolonged opera-
tion with a closed port, stop the pump before opening the 
gate valve.  

Do  not touch  the fluid when  its  temperature is 
higher than 60 °C.  
Do not touch the pump when the surface temperatu-
re is higher than 80 °C.

 

Wait until the water has cooled inside the pump before 
starting again or opening the draining and filling plugs. 
 
 

7.6. Automatic regulator IDROMAT 

         (can be supplied on request) 
For automatic control of starting/stopping of the pump 
when utilization points are opened/closed. 

For protection of the pump: 

• against dry running; 
• against the risk of operation  without  water at the inlet 

(caused by  a lack of water inflow in the inlet pipe under 
positive  suction  head,  by  a non-immersed suction pipe, 
by excessive suction lift  or  by air entering the suction 
pipe); 

• against operation with closed connection ports. 
See installation example par. 12.1

 fig. 2

 

7.7 Switch off of the pump

 

 

 

 

 The appliance must be switch off every time there 

are faults. (see troubleshooting). 

 

The product is designed for a continuous duty,  the swit-
ch off is performed by disconnecting the power supply by 
means the expected disconnecting devices. (see para-
graph "6.5 Electrical connection"). 
 

8 MAINTENANCE 

Before any operations it's necessary to disconnect the 
power supply.  
If required ask to an electrician or to an expert techni-
cian. 

 Every maintenance operations, cleaning or 

reparation executed with the electrical system 
under voltage, it could cause serious injuries to 
people. 

 If the supply cord is damaged, it must be replaced 

by the manufacturer, its service agent or similarly 
qualified persons in order to avoid a hazard. 

In case of extraordinary maintenance, or maintenance 
operations that require part-removing, the operator must 
be a qualified technician able to read schemes and 
drawings. 
It is suggest to  register all maintenance operation execu-
ted.  

 During maintenance keep particular attention in 

order to avoid the introduction of small external 
parts, that could compromise the device safety. 

 It is forbidden to execute any operations with the 

direct use of hands. Use water-resistant, anti-cut 
gloves to disassemble and clean. 

 

 During maintenance operations external 

personnel is not allowed. 

 

Maintenance operations that are not described in this 
manual must be made only by special personnel authori-
zed by Calpeda S.p.A. 
For further technical information regarding the use or the 
maintenance of the device, contact Calpeda S.p.A. 
 
 

8.1 Routine maintenance 

 

 

 

 

 Before every maintenance operations disconnect the 

power supply and make sure that the device could 
not accidentally operate. 

When the pump remains inactive it must be emptied 
completely if there is a risk of freezing 

(

fig. 6

). 

Before  restarting  the  unit,  check that the shaft is not jam-
med and fill the pump casing completely with liquid. 
 

i

ON

i

OFF

IST NG_NGX_NGL REV7 05_2021.qxp_MXS 11_03con gall  24/05/21  09:58  Pagina 10

Summary of Contents for NG

Page 1: ...oblock sj lv evakuerande jet pump med inbyggd ejektor Close coupled zelfaanzuigende jetpompen met ingebouwde venturi jet NG NGX NGL ISTRUZIONI ORIGINALI PER L USO Pagina 2 Italiano OPERATING INSTRUCTI...

Page 2: ...vono essere rispettate altrimenti sono causa di danneggiamenti all apparecchio o compromettono la sicurezza del personale Informazioni ed avvertenze di carattere elettrico il cui mancato rispetto pu d...

Page 3: ...erse da quelle indicate in targa e nelle presenti istruzioni Rispettare la cadenza degli interventi di manutenzione e la tempestiva sostituzione dei pezzi danneggiati o usurati permette all apparecchi...

Page 4: ...e in aspira zione Con il livello dell acqua in aspirazione sopra la pompa funzionamento sotto battente cap 12 1 fig 2 inserire una saracinesca Per aumentare la pressione della rete di distribuzione os...

Page 5: ...empimento 7 6 Regolatore automatico IDROMAT fornibile a richiesta Comanda automaticamente l avviamento della pompa all aper tura degli utilizzi e l arresto alla chiusura Protegge la pompa contro il fu...

Page 6: ...one c Pulire o sostituire la valvola di fondo e impiegare un tubo di aspirazione idoneo d Pulire il filtro se necessario sostituirlo Vedere anche punto 2b a Usare tubi e accessori idonei all impiego b...

Page 7: ...le chapter 6 5 The type of electrical protection to be installed chapter 6 5 1 1 Symbols To improve the understanding of the manual below are indicated the symbols used with the related meaning Inform...

Page 8: ...ing instructions and the indications defined for the different steps from transportation to disposal The specialized technicians must carefully comply with all applicable standards and laws including...

Page 9: ...1 fig 3 fit a foot valve with strainer which must always remain immersed or a check valve on the suction connection If operating with flexible hoses use a semi rigid suction hose in order to avoid th...

Page 10: ...temperatu re is higher than 80 C Wait until the water has cooled inside the pump before starting again or opening the draining and filling plugs 7 6 Automatic regulator IDROMAT can be supplied on requ...

Page 11: ...oot valve blocked or suction pipe not fully immersed in liquid 3d Suction filter blocked 4a Pipes and accessories with diameter too small 4b Presence of deposits or solid bodies in the impeller 4c Rot...

Page 12: ...arlegt Den maximale zul ssigen Geh useenddruck Kapitel 3 1 Typ und Querschnitt des Anschlusskabels Kapitel 6 5 Den Typ der zu installierenden elektri schen Absicherung Kapitel 6 5 1 1 Verwendete Symbo...

Page 13: ...se sorgf ltig durchzulesen Lesen und beachten Sie alle technische Anweisungen Betriebsanleitungen und Hinweise ber s mtliche Arbeitsphasen vom Transport bis zur endg ltigen Entsorgung welche in diesem...

Page 14: ...ten du rfen nicht kleiner als die Pumpenstutzen sein 6 4 2 Saugleitung Fu r F rderstr me u ber 4 m3 h ist eine Saugleitung G 1 1 4 DN 32 zu verwenden Die Saugleitung mu unbedingt luftdicht sein Bei In...

Page 15: ...trieb mit geschlossener Druckleitungs ffnung f hrt zum Bruch bzw Besch digung von Pumpenteilen siehe Kapitel 7 6 Wenn das Wasser wegen l ngeren Betriebs gegen geschlossenen Absperrschieber berhitzt is...

Page 16: ...Siehe auch Punkt 2b a Verwenden Sie Verrohrung und Armaturen entsprechend Ihrer Anwendung b Reinigen Sie das Laufrad und bauen Sie einen Ansaugfilter ein c Ersetzen Sie das Laufrad d Laufrad und Pumpe...

Page 17: ...ompe chapitre 3 1 Le type et la section du c ble d alimen tation chapitre 6 5 Le type de protection lectrique instal ler chapitre 6 5 1 1 Pictogrammes utilis s Pour une compr hension plus facile les s...

Page 18: ...ons techniques de fonctionnement doivent tre lues et observ es correctement ainsi que les indications donn es dans le manuel selon les diff rents passages du transport au d mant lement final Les techn...

Page 19: ...ices de la pompe 6 4 2 Tuyau d aspiration Pour d bits sup rieurs 4 m3 h utiliser un tuyau d aspira tion G 1 1 4 DN 32 Le tuyau d aspiration doit tre parfaitement tanche Avec la pompe au dessus du nive...

Page 20: ...eau est surchauff e pour le fonctionnement pro long avec orifice ferm arr ter la pompe avant d ouvrir la vanne Ne pas toucher le fluide quand sa temp rature est sup rieure 60 C Ne pas toucher la pomp...

Page 21: ...accessoires avec un diam tre trop petit b Pr sence de d p ts et de corps trangers dans la roue c Rotor d terior d Rotor et corps de pompe us s e Gaz dissous dans l eau f Viscosit du liquide pomp g Se...

Page 22: ...tipo de protecci n el ctrica que se instalar el Cap tulo 6 5 1 1 S mbolos utilizados Para mejorar la comprensi n se utilizan los s mbolos picto gramas a continuaci n con sus significados Informaci n...

Page 23: ...r toda informaci n sobre la seguridad Es necesario leer cuidadosamente y seguir las instrucciones t cnicas de funcionamiento y las indicaciones aqu contenidas para los diferentes pasos del transporte...

Page 24: ...m3 h utilizar un tubo de aspiraci n G 1 1 4 DN 32 La tuber a de aspiraci n debe poseer una perfecta estan queidad Con la bomba por encima del nivel del agua funcio namiento en aspiraci n cap 12 1 fig...

Page 25: ...agua El funcionamiento prolongado con la boca de impulsi n cerrada lleva a la rotura o al da o de partes de la bomba ver cap tulo 7 6 Cuando el agua sufre un aumento de temperatura por funcionamiento...

Page 26: ...el punto 2b a Utilizar una tuber a y accesorios id neas a la utilizaci n b Limpiar el rodete e instalar un filtro en aspiraci n c Sustituir el rodete d Sustituir el rodete y el cuerpo de bomba e Abrir...

Page 27: ...tel 6 5 Typ av elektriska skydd som ska installeras kapitel 6 5 1 1 Symboler som anv nds F r att underl tta f rst elsen anv nds de symboler piktogram som indikeras nedan med respektive betydelser Info...

Page 28: ...igenom och f lj alla tekniska instruktioner funktionsanvisningar och indikationer som finns i denna handbok f r de olika skedena allt fr n transport till slutlig kassering De specialutbildade teknike...

Page 29: ...ngar anv ndes h ll emot vid tdragning med ett andra verktyg f r att ej deformera pumphuset R rdiametrarna f r aldrig understiga pumpens anslut ningsdimensioner 6 4 2 Sugledning F r kapaciteter ver 4 m...

Page 30: ...set se avsnitt 7 6 Om pumpen blivit verhettad genom att k rning mot st ngd ventil f rekommit under en l ngre tid skall pum pen stoppas f re ventilen ppnas F rsiktighet m ste iakttagas n r v tsketemper...

Page 31: ...pumphjulet och montera ett filter i inloppet c Byt ut pumphjulet d Byt ut pumphjulet och pumphuset e Utf r man vrarna f r ppning och st ngning av ventilen i utloppet f Pumpen r ej anpassad v tskan g...

Page 32: ...ing skabel hoofdstuk 6 5 Het type en het gedeelte over montage van de electrische beveiliging hoofdstuk 6 5 1 1 Gebruikte symbolen Voor een beter begrip zijn de onderstaande symbolen pic togrammen met...

Page 33: ...dsaanwijzingen te kennen Alle technische instructies voor het functioneren en de aanwijzingen voor de diverse passages van het transport tot aan de definitieve afvoer die hier zijn gegeven moeten aan...

Page 34: ...aandraaien van koppelingen dient u het pomphuis vast te houden met een tweede sleutel Verzeker u ervan dat de aansluiting niet beschadigt door overmatig hard aandraaien De leidingdiameters mogen niet...

Page 35: ...leiding of aftapplug gen te openen 7 6 Automatische pompschakelaar IDROMAT wordt geleverd op verzoek Voor automatisch starten stoppen van de pomp wanneer aftappunten worden geopend gesloten Voor besch...

Page 36: ...f indien noodzakelijk vervang het filter Zie punt 2b a Gebruik de juiste diameter zuig en persleidingen en aansluitdelen voor deze toepassing b Maak de waaier schoon en installeer een filter in de zui...

Page 37: ...8 40 9 41 10 41 11 41 12 52 12 1 52 12 2 54 58 1 Calpeda SpA 2 3 8 3 1 6 5 6 5 1 1 E E 1 2 Calpeda S p A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 1 4 i i OFF O...

Page 38: ...i XXXXXXX Q min max X X m3 h IEC 60034 1 IECX X AAAAXXXXX XXX XXX XXX H max min X X m ESCC2900 MEI XX XX kg IP XX n XXXX min V XXX XXX XXX XXX XXX XXX cos XXX XXX XXX 230 400Y V3 50Hz XX F X X A XXXXX...

Page 39: ...6 6 1 6 2 3 2 6 3 6 4 vx 6 4 1 12 1 4 6 4 2 4 m3 h G 11 4 D 32 12 1 1 3 12 1 2 6 4 3 6 5 L 07 RN F 12 3 TAB 1 30mA 3 mm D NGM NGXM NGLM 220 240V 7 7 1 7 2 OFF i OFF IST NG_NGX_NGL REV7 05_2021 qxp_MXS...

Page 40: ...7 GR 1 3 1m 5 2 7 3 0 5 m 1 m NG 12 1 1 LN 12 1 1 7 4 7 5 7 6 60 C 80 C a o 7 6 IDROMAT 12 1 2 7 7 OFF 6 5 8 CALPEDA SpA CALPEDA SpA 8 1 ON i i OFF IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24...

Page 41: ...12 19 EU WEEE 10 10 1 CALPEDA S p A OFF OFF 11 OFF 1 2 3 4 5 6 a b c d e f a b c a b c d a b c d e f g a b a b c d a b c d a c e f a b c a b c d 2b a b c d e f g a b a b c a b c d 6a 6b 6c IST NG_NGX_...

Page 42: ...9 46 10 46 11 46 12 52 12 1 52 12 2 54 12 3 57 58 1 Calpeda S p A 2 3 CE 8 3 1 6 5 6 5 1 1 1 2 Calpeda S p A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 1 4 i OFF...

Page 43: ...Q min max X X m3 h IEC 60034 1 IECX X AAAAXXXXX XXX XXX XXX H max min X X m ESCC2900 MEI XX XX kg IP XX n XXXX min V XXX XXX XXX XXX XXX XXX cos XXX XXX XXX 230 400Y V3 50Hz XX F X X A XXXXXXXX S1 l c...

Page 44: ...1 25 6 6 1 6 2 3 2 6 3 6 4 6 4 1 12 1 4 6 4 2 4 G 1 1 4 DN 32 12 1 1 3 12 1 2 6 4 3 6 5 07 RN F 12 3 TAB 1 I N 30 mA 3 D NGM NGXM NGLM 50 220 240 7 7 1 OFF i IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03c...

Page 45: ...7 RU 7 2 12 1 1 3 1 12 1 5 12 1 2 7 3 0 5 1 NG 12 1 1 12 1 1 7 4 7 5 5 7 6 60 80 7 6 IDROMAT 12 1 2 7 7 6 5 8 Calpeda S p A Calpeda S p A i i ON OFF IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 2...

Page 46: ...Rev 7 RU 11 OFF 1 2 3 4 5 6 a a a a a a C a 2 a a 6 6 6 8 1 12 1 6 8 2 8 3 IP55 IP55 LOCTITE 510 9 2012 19 EU WEEE 10 10 1 Calpeda S p A OFF OFF IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24 05...

Page 47: ...50 10 50 11 51 12 52 12 1 52 12 2 54 12 3 57 58 1 CALPEDA S P A 2 3 CE 8 3 1 6 5 6 5 1 1 1 2 CALPEDA S P A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 1 4 i i OFF...

Page 48: ...XXXX Q min max X X m3 h IEC 60034 1 IECX X AAAAXXXXX XXX XXX XXX H max min X X m ESCC2900 MEI XX XX kg IP XX n XXXX min V XXX XXX XXX XXX XXX XXX cos XXX XXX XXX 230 400Y V3 50Hz XX F X X A XXXXXXXX S...

Page 49: ...6 3 6 4 6 4 1 12 1 4 6 4 2 4m3 h G1 1 4 DN32 12 1 1 3 12 1 2 6 4 3 _ 6 5 H07RN F 12 3 30 3mm D NGM NGXM NGLM 220 240V 50Hz 7 7 1 7 2 12 1 1 3 1m 12 1 5 12 1 2 7 3 OFF OFF i IST NG_NGX_NGL REV7 05_2021...

Page 50: ...4 7 5 5 60 80 7 6 IDROMAT 12 1 2 7 7 6 5 8 CALPEDA CALPEDA S P A 8 1 6 8 2 8 3 IP 55 IP 55 LOCTITE 510 9 WEEE 2012 19 EU 10 10 1 CALPEDA S P A OFF OFF OFF i i ON IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11...

Page 51: ...c 1d 1e 1f 2a 2b 3c 3a 3b 3c 3d 4a 4b 4c 4d 4e 4f 4g 5a 5b 6a 6b 6c 6d 1a 1b 1c 1d a c 1e 2 1f 2a 2b 2c 3a 3b 3c 3d 2b 4a 4b 4c 4d 4e 4f 4g 5a 5b 6a 6b 6c 6a 6b 6c 6d 6a 6b 6c IST NG_NGX_NGL REV7 05_2...

Page 52: ...unzionamento sotto battente Positive suction head operation Zulaufbetrieb Fonctionnement en charge Funcionamiento bajo carga Tillrinning sugsidan Toeloopsituatie Fig 3 Funzionamento in aspirazione Suc...

Page 53: ...ione Installation examples Einbaubeispiele Exemples d installation Ejemplos de instalaciones Installationsexempel Installatievoorbeelden Fig 4 Sostegni ed ancoraggi delle tubazioni Supports and clamps...

Page 54: ...76 04 76 00 90 04 76 54 98 04 98 00 98 08 NGX NGXM 94 02 94 00 76 54 28 20 1 90 00 88 00 92 00 82 00 82 00 76 20 76 16 82 04 81 00 78 00 73 00 14 04 14 06 22 12 22 16 28 04 28 12 36 52 14 20 26 06 46...

Page 55: ...ntaje Ritning f r demontering och montering Onderdelentekening NGL 76 04 76 00 90 04 76 54 98 04 98 00 98 08 NGL NGLM 94 02 94 00 76 54 28 20 1 90 00 88 00 92 00 82 00 82 04 81 00 78 00 73 00 22 12 22...

Page 56: ...6 00 28 00 32 00 14 20 26 00 94 02 98 04 82 00 3 94 116 90 00 82 04 88 00 26 02 14 46 14 04 22 00 22 12 14 12 22 08 22 04 36 54 3 94 116 1 B NG 6 92 00 76 00 78 00 36 00 28 20 73 00 14 24 14 00 28 04...

Page 57: ...Corrente nominale dell apparecchio Rated current of appliance Bemessungsstrom des Gerates Courant nominal de l appareil Corriente nominal del aparato Enhetens nominella str m Dimensiestroom van appara...

Page 58: ...ulations 2016 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 The Ecodesign for Energy Related Products and Energy Information Amendm...

Page 59: ...30 EU 2014 35 EU og er i overensstemmelse med de heri indeholdte standarder Kommissionens forordning nr 2019 1781 D F E DK CALPEDA S p A intygar att pumpar NG NGM NGL NGLM NGX NGXM pumptyp och serienu...

Page 60: ...60 64 NG NGL NGX Rev 7 IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24 05 21 09 59 Pagina 60...

Page 61: ...61 64 NG NGL NGX Rev 7 IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24 05 21 09 59 Pagina 61...

Page 62: ...62 64 NG NGL NGX Rev 7 IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24 05 21 09 59 Pagina 62...

Page 63: ...63 64 NG NGL NGX Rev 7 IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24 05 21 09 59 Pagina 63...

Page 64: ...da s p a Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia Tel 39 0444 476476 E mail info calpeda it www calpeda com IST NG_NGX_NGL REV7 05_2021 qxp_MXS 11_03con gall 24 05 21 09 59 Pagin...

Reviews: