12. Troubleshooting

WARNING:

Turn off the power supply before performing any operations.

Do not allow the pump or motor to run  when dry even for a short period
Strictly follow the user instructions and if necessary contact an authorised service centre

OFF

PROBLEM 

1) The engine

does not start

2) Pump

blocked

3)The pump 

functions  but
no water
comes out 

4) Insufficient

flow

5) Noise and

vibrations
from the pump

6) Leakage from

the mechani-
cal seal

PROBABLE CAUSES

1a) Unsuitable power supply
1b) Incorrect electrical connections 
1c)  Engine overload protective device

cuts in.

1d) Blown or defective fuses
1e) Shaft blocked
1f) Motor failed

2a) Prolonged periods of inactivity .
2b) Presence  of  solid  bodies  in  the

impeller

2c) Bearings blocked

3a) Presence of air inside the pump or

suction pipe

3b) Possible infiltration of air.
3c) Foot  valve    blocked    or  suction

pipe not fully immersed in liquid 

3d) Suction filter blocked

4a) Pipes  and  accessories  with

diameter too small 

4b) Presence  of  deposits  or  solid

bodies in the impeller

4c) Rotor deteriorated 
4d) Worn rotor and pump case
4e) Gases dissolved in the water 
4f) Excessive  viscosity  of  the  liquid

pumped

4g) Incorrect direction of rotation 

5a) Worn bearings 
5b) Unbalanced power supply 

6a) The 

mechanical 

seal 

has

functioned when dry or has stuck 

6b) Mechanical  seal  scored  by

presence  of  abrasive  parts  in  the
liquid pumped 

6c) Mechanical  seal  unsuitable    for

the type of application 

6d) Slight  initial  drip  during  filling    or

on first start-up 

POSSIBLE REMEDIES

1a) Check that the mains frequency  and voltage are

suitable.

1b) Connect the power supply cable correctly. Check

the setting of the thermal overload protection.

1c) Check  the  power  supply  and  make  sure  that  the

pump  shaft  is  turning  freely.  Check  the  setting  of
the thermal overload protection.

1d) Replace the fuses, check points a) and  c)
1e) See “Blocked  pump” instruction booklet
1f) Repair  or replace the engine.

2a) Unblock the pump by using a screw driver to turn

the relevant notch on the back of the shaft.

2b) Remove  any  solid  foreign  bodies  inside  the

impeller

2c) Replace the bearings.

3a) Release the air from the pump using the delivery

control valve.

3b)  Check  which  part  is  not    tight  and  seal    the
connection.
3c) Clean  or  replace  the  bottom  valve  and  use  a

suitable suction pipe .

3d) Clean the filter, if necessary, replace it . See point

2b) also.

4a) Use  pipes  and  accessories  suitable  for  the

specific application 

4b) Clean the impeller and install a suction filter
4c) Replace the impeller
4d) Replace the impeller and the pump casing 
4e) Perform  the  opening  and  closing  manoeuvres

through the feeder gate 

4f) The pump is unsuitable 
4g)  Invert  the  electrical  connections  in  the  terminal
board

5a) Replace the bearings 
5b) Check that the mains voltage is right

In cases 6a), 6b) and 6c), replace the seal
6a) Make sure that the pump casing is full of liquid and

that all the air has been expelled.  

6b) Install a suction filter  and use a seal suited to the

characteristics of the liquid being pumped. 

6c) Choose  a  seal  with  characteristics  suitable  for  the

specific application 

6d) Wait  for  the  seal  to  adjust  to  the  rotation  of  the

shaft.  If  the  problem  persists,  see  points  6a),  6b)
or 6c).

IST N_N4 09_2018_Rev13_MXS 11_03con gall  10/09/18  10:52  Pagina 19

Summary of Contents for N

Page 1: ...on aspiraci n axial PN 10 y soporte Seg n norma europea EN 733 Horisontal axial sugs centrifugalpumpar PN 10 med lagerbock Enligt Europastandard EN 733 PN 10 horizontale end suction centrifugaal pompe...

Page 2: ...pools or where people may enter or come into contact with the water Read carefully the installation section which sets forth The maximum permissible structural working pressure chapter 3 1 The type a...

Page 3: ...or maximum density of 30 cSt 2 2 Improper use The device is designed and built only for the purpose described in paragraph 2 1 Improper use of the device is forbidden as is use under conditions other...

Page 4: ...mensions and weights 5 1 Handling Handle with care the packages must not receive impacts Raise the pump motor unit slowly fig 1 making sure it does not move from side to side in an uncontrolled way to...

Page 5: ...ositive suction head a gate valve must be fitted Follow local specifications if network pressure is to be increased Fit a gate valve into the delivery pipe to adjust deli very head and absorbed power...

Page 6: ...f cou pling at the required torque Insert the two lateral screws of the first half coupling Insert and tighten the two lateral screws of the second half coupling at the required torque Tighten the two...

Page 7: ...equency converter Adjust the frequency converter so that the limiting values of min 25 Hz and max fN Hz will not be exceeded 7 STARTUP AND OPERATION 7 1 Preliminary checks before start up of the pump...

Page 8: ...ely if there is a risk of freezing Fig 9 Before restarting the unit check that the shaft is not jammed and fill the pump casing completely with liquid 8 1 1 Routine maintenance Special construction Be...

Page 9: ...parts for the separation Observe the local regulations and dispose the device accordingly with the international rules for environ ment protection 10 SPARE PARTS 10 1 Spare parts request When ordering...

Page 10: ...REMEDIES 1a Check that the mains frequency and voltage are suitable 1b Connect the power supply cable correctly Check the setting of the thermal overload protection 1c Check the power supply and make...

Page 11: ...9 80 10 80 11 80 12 81 13 82 13 1 82 13 2 85 88 1 CALPEDA S P A 2 3 CE 8 3 1 6 5 6 5 1 1 1 2 CALPEDA S P A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 1 4 i i OF...

Page 12: ...0 1 min kW 7 5 30 75 dB A 70 80 85 90 60 40 20 10 100 m 10 bar 160m 16 bar PN Pa Hmax Pa 3 2 40 4 4 1 CALPEDA S P A 4 2 4 3 4 4 4 5 i N xxxxxx 0705158995 H max min 31 20 m ESCC2900 MEI 0 10 2900 min X...

Page 13: ...3 6 4 4 1 2 25 50mm 3 48 6 4 2 1 5m s 3m s Q DN DN mm 50 65 80 100 125 150 200 250 300 Qmax m3 h 10 5 19 28 8 45 75 108 215 350 508 4 i 4 93 036 1 4 93 038 1 4 93 038 3 2 4 93 038 1 4 93 038 c b a d...

Page 14: ...50 20 12 5 5 6 4 4 6 4 5 N EUPEX 3 4mm 4 6A 6 4 6 Rex Viva 4 6B 6 4 1 6 4 3 6 4 5 6 4 7 N N4 mm 7 5 pump 4 93 037 6A straight edge gage P057 1 riga straight edge 6B straight edge IST N_N4 09_2018_Rev1...

Page 15: ...5 OFF OFF ON 4 93 141 8 110 160 15 PER VITI M12 4 93 041 15 25 s 110 w1 160 h h1 15 d FOR BOLTS M12 R s 4 93 041 110 160 15 F R SCHRAUBEN M12 4 93 041 EN733 h s d w1 h1 24 100 112 180 77 4 32 130 180...

Page 16: ...N4 Rev 13 8 CALPEDA CALPEDA S P A 8 1 50 C 9 8 1 50 C 9 8 2 8 3 8 4 5000 8 2900 3600r p m 1450 1800r p m 78 i i OFF OFF 4 93 142 9 4 93 142 9 IST N_N4 09_2018_Rev13_MXS 11_03con gall 10 09 18 10 53 P...

Page 17: ...8 20 32 04 32 05 34 00 34 12 34 16 36 00 36 50 38 00 42 00 42 04 O 43 00 43 01 O 44 00 44 04 46 00 64 00 60 00 60 02 62 00 62 04 62 08 62 12 63 00 64 00 64 08 64 12 O 64 16 64 20 66 00 66 04 66 08 66...

Page 18: ...1c 1d 1e 1f 2a 2b 3c 3a 3b 3c 3d 4a 4b 4c 4d 4e 4f 4g 5a 5b 6a 6b 6c 6d 1a 1b 1c 1d a c 1e 2 1f 2a 2b 2c 3a 3b 3c 3d 2b 4a 4b 4c 4d 4e 4f 4g 5a 5b 6a 6b 6c 6a 6b 6c 6d 6a 6b 6c IST N_N4 09_2018_Rev13...

Page 19: ...80 180 180 200 225 200 250 280 200 225 250 280 250 280 315 280 315 140 160 180 140 160 180 225 160 180 200 180 200 225 250 280 225 250 280 315 355 280 315 355 400 400 450 355 93 120 140 100 119 140 17...

Page 20: ...780 880 880 1020 1020 1020 1020 1020 1020 1020 1020 1140 880 1020 1020 1020 1020 1020 1020 1020 1020 1140 1360 1360 1360 1020 1020 1020 1020 1230 1360 1360 1360 1360 1250 1250 1230 1360 1360 1360 1250...

Page 21: ...1230 1230 1230 1360 1250 1250 1250 1030 1030 1230 1230 1250 1250 1250 1250 1250 1400 1250 1250 1250 1250 1250 1400 1400 750 750 750 750 750 750 750 750 750 850 850 850 850 750 750 750 850 850 850 850...

Page 22: ...0 36 00 34 00 28 04 14 28 46 00 60 05 60 02 60 06 60 08 60 04 34 00 43 01 43 00 38 00 32 04 44 00 32 05 64 08 64 12 28 20 64 16 64 00 44 04 62 12 14 12 Non presente nei tipi N N4 32 125 A N N4 40 125...

Page 23: ...aft extension Wellen ende Bout d arbre Extremidad eje Axeltapp Schachtver lenging Cuscinetto lato girante Impeller side bearing Lager laufrad seitig Palier c t roue Rodamiento lado rodete Lager pumphj...

Page 24: ...s Tab 1 TAB 1IEC 60335 1 A mm 2 Corrente nominale dell apparecchio Rated current of appliance Bemessungsstrom des Ger tes Dimensiestroom van apparaat Sezione nominale Nominal cross sectional area Nenn...

Page 25: ...overensstemmelse med bestemmelserne i Direktiv 2006 42 EC 2009 125 EC 2014 30 EU 2014 35 EU og er i overensstemmelse med de heri indeholdte standarder Kommissionens forordning nr 547 2012 640 2009 NL...

Reviews: