12.  TROUBLESHOOTING

OFF

 

    

WARNING

: Turn off the power supply before performing any operations.

 Do not allow the pump or motor to run  when dry even for a short period.

 Strictly follow the user instructions and if necessary contact an authorised service centre.

PROBLEM

PROBABLE CAUSES

POSSIBLE REMEDIES

1)

The motor does 

not start

1a) Unsuitable power supply

1b) Incorrect electrical connections 

1c)  Engine overload protective device cuts 

in.

1d) Blown or defective fuses

1e) Shaft blocked

1f)  

If the above causes have already 

been  checked, the engine may be 

malfunctioning

1a)  

Check that the mains frequency  and voltage correspond to the 

electrical characteristics shown on the indicator plate

1b)  Connect the power supply cable to the terminal board correctly. Check 

that the thermal overload protection is  set correctly (see data on the 

engine indicator plate) and make sure that the fuseboard upline of the 

engine has been properly connected

1c)  Check the power supply  and make sure that the pump shaft is turning 

freely. Check that the thermal overload protection has been set 

correctly (see engine indicator plate)

1d)  Replace the fuses, check the electric power supply and points a) and  c)

1e)  Remove the cause of blockage as indicated in the “Blocked  pump” 

instruction booklet

1f)  Repair  or replace the engine by applying to an authorised service 

centre

2) 

Pump blocked

2a)  

Prolonged periods of inactivity with 

formation of rust inside the pump

2b)  Presence of solid bodies in the pump 

rotor

2c) Bearings siezed

2a)  Rotation may be started directly from  the pump shaft or from the 

ύΤόΣt (ΧάΡάΡbάΧ tΤ tuΧΣ Τέέ tίά άΠάΗtΧόΗόtγ suΥΥΠγ зΧst ) ΤΧ ΗΤΣtΕΗt ΕΣ 

authorised service centre 

2b)  If possible, dismantle the pump casing  and remove any solid foreign 

bodies inside the rotor,  if necessary contact an authorised service 

centre 

2c)  If the bearings are damaged replace them or if necessary contact an 

authorised service centre 

3) 

The pump 

functions  

but no water 

comes out 

3Ε)  PΤssόbΠά όΣзΠtΧΕtόΤΣ Τέ ΕόΧ έΧΤΡ suΗtόΤΣ 

tubά ΗΤΣΣάΗtόΤΣs, ΘΧΕόΣ ΥΠuήs ΤΧ зΠΠόΣή 

of pump or from the gaskets of the 

suction pipe

3b)  Foot valve  blocked  or suction pipe not 

fully immersed in liquid 

3Η) SuΗtόΤΣ зΠtάΧ bΠΤΗώάΘ

3a) Check which part is not  tight and seal  the connection adequately  

3b)  Clean or replace the bottom valve and use a suction pipe suitable for 

the application 

3Η) CΠάΕΣ tίά зΠtάΧ, όέ ΣάΗάssΕΧγ, ΧάΥΠΕΗά όt . Sάά ΥΤόΣt 2Ε) ΕΠsΤ.

4) 

IΣsuέзΗόάΣt иΤα

4a)  Pipes and accessories with diameter 

too small causing excessive loss of 

head 

4b)  Presence of deposits or solid bodies in 

the internal passages of the rotor 

4c) Rotor deteriorated 

4Θ) WΤΧΣ ΧΤtΤΧ ΕΣΘ ΥuΡΥ ΗΕsά

4e) 

 

Excessive viscosity of the liquid 

pumped  (if other than water) 

4f) Incorrect direction of rotation 

4g)  Suction head excessive in relation to 

the  suction capacity of pump 

4h) Suction pipe too long 

4Ε) Usά ΥόΥάs ΕΣΘ ΕΗΗάssΤΧόάs suόtΕbΠά έΤΧ tίά sΥάΗόзΗ ΕΥΥΠόΗΕtόΤΣ 

4b)  CΠάΕΣ  tίά  ΧΤtΤΧ  ΕΣΘ  όΣstΕΠΠ  Ε  suΗtόΤΣ  зΠtάΧ  tΤ  ΥΧάvάΣt  ΤtίάΧ  έΤΧάόήΣ 

bodies from entering 

4c) Replace the rotor, if necessary, contact an authorised service centre 

4d) Replace the rotor and the pump casing 

4e) The pump is unsuitable 

4f) Invert the electrical connections on the terminal board  or control panel 

4g)  Try to close the feeder gate partially and/or reduce the difference in 

level of the pump and the liquid being aspirated 

4h)  Bring the pump closer to the suction tank so as to use a shorter pipe. 

If necessary use a pipe of a wider diameter 

5) 

Noise and 

vibrations 

from the pump

5a) Rotating part unbalanced 

5b) WΤΧΣ bάΕΧόΣήs 

5Η) PuΡΥ ΕΣΘ ΥόΥάs ΣΤt зΧΡΠγ ΕttΕΗίάΘ 

5d)  Flow too strong for the diameter of the 

delivery pipe 

5e) Functioning in cavitation 

5f) Unbalanced power supply 

5g) Incorrect alignment of pump-motor unit

5a) Check that no solid bodies are obstructing the rotor 

5b) Replace the bearings 

5c) Anchor the delivery and suction piping as needed 

5Θ) Usά bόήήάΧ ΘόΕΡάtάΧs ΤΧ ΧάΘuΗά tίά ΥuΡΥ иΤα

5ά)  RάΘuΗά tίά иΤα bγ ΕΘύustόΣή tίά έάάΘάΧ ήΕtά  ΕΣΘ/ΤΧ usόΣή ΥόΥάs αόtί 

a bigger internal diameter. See point 4g) too

5f) Check that the mains voltage is right

5g) If necessary, the unit must be re-aligned

6)  

Leakage from 

the mechanical 

seal

6a)  The mechanical seal has functioned 

when dry or has stuck 

6b)  Mechanical seal scored by presence 

of abrasive parts in the liquid pumped 

6c)  

Mechanical seal unsuitable  for the 

type of application 

6Θ)  SΠόήίt όΣόtόΕΠ ΘΧόΥ ΘuΧόΣή зΠΠόΣή  ΤΧ ΤΣ зΧst 

start-up

In cases 6a), 6b) and 6c), replace the seal, if necessary contact an 

authorised service centre 

6a)  Make sure that the pump casing  (and the suction pipe if the pump is 

not  self-priming) are full of liquid and that all the air has been expelled. 

See point 5 e) too. 

6b)  IΣstΕΠΠ Ε suΗtόΤΣ зΠtάΧ  ΕΣΘ usά Ε sάΕΠ suόtάΘ tΤ tίά ΗίΕΧΕΗtάΧόstόΗs Τέ tίά 

liquid being pumped. 

6Η) CίΤΤsά Ε sάΕΠ αόtί ΗίΕΧΕΗtάΧόstόΗs suόtΕbΠά έΤΧ tίά sΥάΗόзΗ ΕΥΥΠόΗΕtόΤΣ 

6d)  

WΕόt  έΤΧ  tίά  sάΕΠ  tΤ  ΕΘύust  tΤ  tίά  ΧΤtΕtόΤΣ  Τέ  tίά  sίΕέt.  Iέ  tίά  ΥΧΤbΠάΡ 

persists, see points 6a), 6b) or 6c) or contact an authorised service centre.

www.calpeda.su

www.calpeda.su

Summary of Contents for 70020030000

Page 1: ...lokpompen met periferische waaier CT T TP ISTRUZIONI ORIGINALI PER L USO Pagina 2 Italiano OPERATING INSTRUCTIONS Page 8 English BETRIEBSANLEITUNG Seite 14 Deutsch INSTRUCTIONS POUR L UTILISATION Page...

Page 2: ...ne del cavo di alimentazione capitolo 6 5 il tipo di protezione elettrica da installare capitolo 6 5 1 1 Simbologia utilizzata Per migliorare la comprensione si utilizzano i simboli tt s tt t t t v s...

Page 3: ...s ut t v t t us t uso non previste dal presente manuale L ut tt t tt st s u C u ss ritenuta responsabile per guasti o infortuni dovuti ss v v t s t t 2 3 Marcatura D s u t u t tt t s t su v u st 1 Tip...

Page 4: ...sub u t Si deve evitare di sovrapporre agli imballi altro materiale che potrebbe deteriorare la pompa S s su 25 K b v ss sollevato da due persone contemporaneamente 6 INSTALLAZIONE 6 1 Dimensioni di...

Page 5: ...almeno 3 mm Con alimentazione trifase installare un adeguato salvamotore con curva D come da corrente di targa Le elettropompe monofasi CTM TM TPM sono fornite con condensatore collegato ai morsetti e...

Page 6: ...datti provvedimenti 8 2 S t t Prima dello smontaggio chiudere le saracinesche in aspirazione e mandata 8 3 Smontaggio della pompa OFF Prima dello smontaggio chiudere le saracinesche in aspirazione e m...

Page 7: ...ori con diametro troppo piccolo che causano eccessive perdite di carico b Presenza di depositi o corpi solidi nei passaggi interni della girante c Girante deteriorata d Rasamenti di girante e corpo po...

Page 8: ...d section of the power cable chapter 6 5 The type of electrical protection to be installed chapter 6 5 1 1 Symbols To improve the understanding of the manual below are indicated the symbols used with...

Page 9: ...tructions Improper use of the product reduces the safety and t t v C s t b responsible for failure or accident due to improper use 2 3 Marking The following picture is a copy of the name plate that is...

Page 10: ...st be handled by two person at the same time 6 INSTALLATION 6 1 Dimensions For the dimensions of the device see technical catalogue 6 2 Ambient requirements and installation site dimensions The custom...

Page 11: ...above the water level suction lift operation or with a positive suction head which is too low less than 1 m to open the non return v v t u t u t When the liquid level on the suction side is above the...

Page 12: ...the suction and delivery gate valves before dismantling For dismantling and re assembly see construction in the cross section drawing To remove the impeller 28 00 T TP use the threaded dismantling ho...

Page 13: ...e connection adequately 3b Clean or replace the bottom valve and use a suction pipe suitable for the application 3 C t t ss t S t 2 s 4 I su t 4a Pipes and accessories with diameter too small causing...

Page 14: ...darlegt Den maximale zul ssigen Geh useenddruck Kapitel 3 1 Typ und Querschnitt des Anschlusskabels Kapitel 6 5 Den Typ der zu installierenden elektrischenAbsicherung Kapitel 6 5 1 1 Verwendete Symbo...

Page 15: ...ehlan wendung Das Ger t wurde ausschlie lich zu den im Abschnitt 2 1 beschriebenen Zwecken entworfen und hergestellt Die Verwendung vom Ger t zu anderen unzul ssigen Zwecken oder unter in diesem Handb...

Page 16: ...rtieren Die Mittel zum Transport des verpackten Ger tes m ssen f r die Abmessungen und das Gewicht des gekauften Produktes geeignet sein siehe Katalog Gesamtabmessungen 5 1 Handhabung Heben Sie die Ve...

Page 17: ...vorzusehen D E s W s st u CTM TM TPM werden bei mit angeschlossenem Anlaufkondensator im Klemmenkasten und bei 220 240 V 50 Hz mit eingebautem Thermoschalter geliefert 7 ANLAUF UND BETRIEB 7 1 Kontrol...

Page 18: ...rden ist Eventueli durch geeignete Ma nahmen reinigen 8 2 Demontage der Anlage Vor der Demontage die Saug und Druckschieber schlie en 8 3 Demontage der Pumpe OFF Vor Demontage Absperrorgane vor und hi...

Page 19: ...ilter reinigen oder falls erforderlich ersetzen Siehe auch Punkt 2a 4 Zu geringe F rdermenge 4a Verrohrung und Armaturen mit zu kleiner Nennweite verusachen zu gro e Verluste 4b Feststoffe oder Ablage...

Page 20: ...tre 3 1 Le type et la section du c ble d alimentation chapitre 6 5 Le type de protection lectrique installer chapitre 6 5 1 1 Pictogrammes utilis s Pour une compr hension plus facile les symboles pict...

Page 21: ...et selon des modalit s non pr vues dans ce manuel L ut s t u u t t s t st u s s u t t t Calpeda ne peut tre retenue responsable des pannes u s ts us bs v t s t t s pr sent es ci dessus 2 3 Marquage C...

Page 22: ...ivent tre ad quats aux dimensions et aux poids du produit choisi voir catalogue technique dimensions b t 5 1 Manutention D b v s v t t ut I ut v t s su s u ts b s ut s mat riels qui pourraient d t rio...

Page 23: ...our d connecter t t v u st uv tu s t ts u s 3 P u t t t s st u t t moteur appropri e avec courbe D selon le courant indiqu sur la plaque signal tique Les pompes monophas es CTM TM TPM sont fournies av...

Page 24: ...bouchon 14 12 s st Pour vidanger compl tement les pompes CT d monter la pompe et la renverser A s u u t v t tt s b t u u s t pas bloqu e par des incrustations d p ts ou ut s us s S ss tt v mesures ap...

Page 25: ...c un diam tre trop petit entra nant des pertes de charge 4b P s ts t s t s s t u u ss u t 4c Rotor d terior 4d Rotor et corps de pompe us s 4e Viscosit du liquide pomp si autre u u 4f Sens de rotation...

Page 26: ...ctrica que se instalar el Cap tulo 6 5 1 1 S mbolos utilizados Para mejorar la comprensi n se utilizan los s mbolos t s t u sus s s Informaci n y advertencias que deben respetarse si no causan da os...

Page 27: ...a el uso descrito en el p r 2 1 Est totalmente prohibida la utilizaci n del dispositivo para usos impropios y que no est n indicados en este manual El uso impropio del producto deteriora las t st s s...

Page 28: ...no debe ser golpeado Hay que evitar la superposici n al embalado de otro material que podr a da ar la bomba Si el peso supera los 25 Kg el embalado tiene que ser levantado por dos personas al mismo t...

Page 29: ...arte deteriorada 7 2 Primer arranque OFF ATENCI N Evitar absolutamente el funcionamiento de la bomba en seco Poner la bomba en marcha nicamente despu s de haberla llenado completamente de l quido Con...

Page 30: ...rodete no esta bloqueado por incrustaciones o por otras causas Limpiar eventualmente con adecuada precauci n 8 2 Desmontaje del sistema Antes del desmontaje cierre las compuertas en aspiraci n y desca...

Page 31: ...Limpiar o sustituir la v lvula de fondo y utilizar un tubo de aspiraci n id neo a la aplicaci n L t s s s sust tu V t b u t 2 4 Caudal su t a Tuber a y accesorios con di metro demasiado peque o que pr...

Page 32: ...yp av elektriska skydd som ska installeras kapitel 6 5 1 1 Symboler som anv nds F r att underl tta f rst elsen anv nds de symboler piktogram som indikeras nedan med respektive betydelser Information o...

Page 33: ...absolut f rbjudet att anv nda apparaten f r felaktiga ndam l och att anv nda den p s tt som inte f rutsetts i denna handbok En felaktig anv ndning av produkten f rs mrar s kerhetsegenskaperna och appa...

Page 34: ...rtfordonet r l mpligt f r emballagens totala ytterm tt Det kr vs inga s rskilda hj lpmedel f r att transportera den f rpackade produkten Fordonen f r transport av den f rpackade pumpen ska vara anpass...

Page 35: ...dfelsbrytare v st I N 30 A installeras i str mkretsen Installera en arbetsbrytare med minimum 3 mm luftspalt f r brytning av alla tre faserna Vid en trefasinstallation skall ett motorskydd installeras...

Page 36: ...Avl gsna pumphuslocket 12 00 eller s u 14 12 s tt t mma pumparna i T TP serierna F r att helt t mma CT pumparna skall dessa demonteras samt v ndas upp och ner 8 2 Nedmontering av anl ggningen St ng i...

Page 37: ...tillbeh r med f r liten diameter medf r stora f rluster 4b N rvaro av f roreningar i pumphjulet 4c Pumphjul igensatt 4d Slitet pumphus eller pumphjul 4e verskriden viskositet p v tskan om annat n vat...

Page 38: ...fdstuk 6 5 1 1 Gebruikte symbolen Voor een beter begrip zijn de onderstaande symbolen pictogrammen met hun betekenis gebruikt Informatie en waarschuwingen die in acht moeten worden genomen zo niet dan...

Page 39: ...t apparaat onjuist te gebruiken en voor doeleinden die niet beschreven zijn in dit handboek Het onjuiste gebruik van het product tast de v s t v t t D C S A t v t worden gehouden voor defecten of onge...

Page 40: ...de verpakking door twee personen tegelijkertijd worden opgetild 6 INSTALLATIE 6 1 Benodigde ruimte Zie voor de benodigde ruimte van het apparaat de bijlage Benodigde ruimte zie technische catalogus 6...

Page 41: ...ngeschakeld worden wanneer er beschadigde onderdelen zijn 7 2 Eerste inschakeling OFF LET OP Laat de pomp nooit drooglopen Start de pomp nadat deze volledig is gevuld met vloeistof Als de pomp geplaat...

Page 42: ...dient voor hertstart de waaier gecontroleert te worden op vaste delen en andere vervuilingen Indien noodzakelijk de waaier schoonmaken 8 2 Demontage van de installatie Sluit de schuiven van aanzuigin...

Page 43: ...d met het medium 3 Zu t b 3a Vontroleer welke delen niet luchtdicht zijn en verbind de verbindingen adequaat 3b Maak de voetklep schoon of vervang die gebruik de juiste zuigleiding voor de toepassing...

Page 44: ...GR 44 64 CT T TP Rev24 CALPEDA S A 1 C S A 2 3 8 3 1 6 5 6 5 1 1 i E E OFF ON 1 44 2 45 3 45 4 45 5 46 6 46 7 47 8 47 9 48 10 48 11 48 12 49 62 64 w w w c a l p e d a s u www calpeda su...

Page 45: ...s 13 14 15 16 Made in Italy MONTORSO XXXXXXX Q min max X X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F VICENZA 1 2 3 4 5 6 7 8 9 10...

Page 46: ...GR 46 64 CT T TP Rev24 i CALPEDA S A 4 2 4 3 4 4 4 5 5 5 1 25 6 6 1 6 2 3 2 6 3 i 6 4 6 4 1 6 4 2 w w w c a l p e d a s u www calpeda su...

Page 47: ...GR CT T TP Rev24 47 64 6 4 3 15 6 5 OFF L 5 5 W 07 RN F 13 1 TAB 1 30 A 3 D CTM TM TPM 220 240V 7 7 1 7 2 OFF 1 5 7 3 OFF ON 6 5 8 w w w c a l p e d a s u www calpeda su...

Page 48: ...4 28 00 28 20 Impeller key 32 00 36 00 36 50 36 52 46 00 70 00 70 18 73 00 73 12 Circlip 76 00 76 04 76 16 Support 76 35 76 54 Terminal box set 78 00 81 00 81 08 Circlip 82 00 Motor end shield fan sid...

Page 49: ...4 4 64 12 OFF 1 1 1b 1 1 1 1 1a 1b 1 1 1 1 2 2 2b 2 2 2b 2 3 3 3b 3c 3 3b 3 2b 4 4a 4b 4 4d 4 4 4 4 4a 4b 4 4 4 4 4g 4 5 5 5b 5 5 5 5 5 5b 5 5d 5 5 6 6 6b 6c 6 6 6b 6 6 6b 6 6 w w w c a l p e d a s u...

Page 50: ...RU C 50 64 CT T TP Rev24 CALPEDAS P A 1 C S A 2 3 CE 8 3 1 6 5 6 5 1 1 i OFF ON 1 50 2 51 3 51 4 51 5 52 6 6 52 7 53 8 53 9 54 10 54 11 54 12 55 62 64 w w w c a l p e d a s u www calpeda su...

Page 51: ...8 9 10 11 12 13 14 15 16 Made in Italy MONTORSO XXXXXXX Q min max X X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F VICENZA 1 2 3 4 5...

Page 52: ...RU C 52 64 CT T TP Rev24 i C S A 4 2 4 3 4 4 4 5 5 5 1 25 6 6 1 6 2 3 2 6 3 i 6 4 6 4 1 6 4 2 w w w c a l p e d a s u www calpeda su...

Page 53: ...RU CT T TP Rev24 C 53 64 6 4 3 15 6 5 OFF 5 5 07 RN F 13 1 TAB 1 I N 30 A 3 D CTM TM TPM 50 220 240 7 7 1 7 2 OFF 1 5 7 3 ON 6 5 8 w w w c a l p e d a s u www calpeda su...

Page 54: ...10 1 C S A 11 Nr 12 00 12 20 14 00 14 12 14 20 14 24 14 42 28 00 28 20 32 00 36 00 36 50 36 52 46 00 70 00 70 18 73 00 73 12 76 00 76 04 76 16 76 35 76 54 78 00 81 00 81 08 82 00 82 04 82 08 88 00 90...

Page 55: ...RU CT T TP Rev24 C 55 64 12 OFF 1 2 3 2 4 5 4 6 5 6 6 6 w w w c a l p e d a s u www calpeda su...

Page 56: ...2 3 CE 8 3 1 6 5 6 5 1 1 i OFF ON 1 2 CALPEDA P A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 i 1 4 1 56 2 57 3 57 4 57 6 58 7 58 8 59 9 59 10 60 11 60 12 60 13 6...

Page 57: ...max X X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F VICENZA 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 3 3 1 2900 3450rpm IP54 240V 1 5...

Page 58: ...58 64 CT T TP Rev24 4 4 4 5 5 5 1 25 6 6 1 6 2 3 2 6 3 i 6 4 6 4 1 6 4 2 6 4 3 _ 15m 6 5 OFF w w w c a l p e d a s u www calpeda su...

Page 59: ...CT T TP Rev24 59 64 5 5kw H07RN F 13 1 30 3mm D C M M PM 220 240V 50Hz 7 7 1 7 2 OFF 1m 5 7 3 ON 6 5 8 i i CALPEDA CALPEDA P A 8 1 OFF 12 00 14 12 C w w w c a l p e d a s u www calpeda su...

Page 60: ...00 12 20 14 00 14 04 14 12 14 20 O 14 24 28 00 28 20 32 00 36 00 36 50 36 52 46 00 70 00 70 18 73 00 73 12 76 00 76 04 76 16 76 35 76 54 78 00 81 00 81 08 82 00 82 04 82 08 88 00 90 00 90 04 92 00 94...

Page 61: ...a 1b 1c 1d a c 1e 2 1f 2 2a 2b 2c 2a 2b 2c 3 3a 3b 3c 3a 3b 3c 2a 4 4a 4b 4c 4d 4e 4f 4g 4h 4a 4b 4c 4d 4e 4f 4g 4h 5 5a 5b 5c 5d 5e 5f 5g 5a 5b 5c 5d 5e 4g 5f 5g 6 6a 6b 6c 6d 6a 6b 6c 6a 5e 6b 6c 6d...

Page 62: ...ntering och montering Onderdelentekening 90 04 76 00 78 00 73 00 36 00 92 00 46 00 70 18 36 50 14 12 12 20 81 00 82 04 94 02 76 04 94 00 76 54 98 00 98 08 14 00 98 04 70 00 14 04 82 00 90 00 88 00 3 9...

Page 63: ...ur d montage et montage Dibujo para desmontaje y montaje Ritning f r demontering och montering Onderdelentekening CT 61 Tab 1 TAB 1IEC 60335 1 A mm 2 Corrente nominale dell apparecchio Rated current o...

Page 64: ...at vore pumper CT T TP B I M pumpe type og serie nummer vist p typeskiltet er fremstillet i overensstemmelse med bestemmelserne i Direktiv 2006 42 EC 2009 125 EC 2014 30 EU 2014 35 EU og er i overenss...

Reviews: