1. Use UL approved electrical wires, stranded copper, connected to 110-120V AC electricity.
Electrical wires MUST have a minimum capacity for 15 Amp current. See Figure A below for the
correct electrical wire gauge size. Wires must be placed in a PVC or other underground conduit.
2. Turn off the AC power from the main power source circuit breaker.
3. Connect the green wire to the green wire (GROUND) wire using a wire nut (Figure B).
a. Alternative: connect the green wire to the earth ground rod and AC ground wire nut. Note:
The earth ground rod can be grounded to the chassis.
4. Connect the white wire to the white wire (NEUTRAL) using a wire nut.
5. Connect the black wire to the black wire (HOT/LINE) using a wire nut.
6. All operators MUST be properly grounded in order to prevent an electrical charge. Must use a
dedicated circuit for power supply.
7. Turn ON AC power from the main power source.
8. Turn the power switch on the gate operator to the ON position. For DCFP model gate
operators, turn the battery switch to the ON position, Figure C
Power
Battery
Figure B
Black
Black
White
White
Green
Green
110-120V AC Power Cable
Gate Operator Power Cable
(located in the bottom)
Step 4: Connecting the Power
12
Electrical Wire Gauge Chart
Distance
Gauge
0 - 200 ft
14 AWG
201-400 ft
12 AWG
401-650 ft
10 AWG
Figure C
Figure A
651-1000 ft
8 AWG
1001-2000 ft
4 AWG