Accessory Wiring
31
•
Fire Access Box
•
Use 14-20 gauge awg wire (not included) and splice (join) with the white and black wires.
•
Common (White wire) - 24V-COM
•
N/O (Black wire) - EXIT LOOP
•
Safety Edge / Edge Sensor
•
The Calimet CM9-934 Safety Edge is wireless and requires no wiring.
•
For other brand safety edges, use the MON-CLOSE or MON-OPEN input depending on if it's
monitoring the open or close cycle. Use COMMON and MON-24VDC if the safety edge requires
electricity.
•
Keypad
For the Calimet CM9-535 Wireless keypad, follow the separate keypad instruction manual for
installation details.
For wired and non-Calimet brand keypads, use a 20 gauge stranded electrical wire and connect using
the following:
Normal Open/Relay - Relay
Common - 24V-COM
12-24VDC - 24-VDC
Access Controllers/Intercoms
Use a 20 gauge stranded electrical wire and connect using the following:
Normal Open/Relay - Relay
Common - 24V-COM
12-24VDC - 24-VDC
If the intercom/access controller requires a dedicated Normal Open/Normal Close input, use the EXIT
LOOP input on the bottom right of the circuit board for Normal Open, and the CL input for Normal
Close. The 24-VDC and the 24V-COM can supply electricity to the intercom/access controller.