Cell Connection – System Monitor
•
Reset on Signal Loss
Fixed-point connections expect to have consistent access to the cellular network, compared to mobile connections
that may temporarily lose access depending on coverage. This option causes the modem to reset if the cell
connection is lost for longer than the duration that you specify in the Signal Loss Timeout.
•
Signal Loss Timeout
If a reset on Signal loss (above) is enabled; specify the amount of time in seconds for which a loss of connection will
trigger a reset of the modem.
Periodic Reset Timer
•
Periodic Reset Type
Sets the Periodic Modem Reset timer to a time Interval or a scheduled time, or disables it.
•
Interval Length
Sets the Periodic Modem Reset time from 15 to 65,535 minutes. The Periodic Reset is disabled when set to 0.
Default is set to 4320 min. (approximately 3 days)
•
Scheduled Time
Sets the Periodic Modem Reset to occur at the specified time. Select the days of week desired or 'All' for everyday.
Time is specified in UTC,
not
Local Time where the modem is located. The modem's current time is shown on the
"home" page.
Periodic Ping Settings
•
Destination Address
User may enter an accessible IP address or URL that will respond to a ping command.
•
Secondary Address
User may enter an accessible IP address or URL that will respond to a ping command. This address will be used if the
entered number of consecutive ping failures using the first address is reached.
•
Periodic Ping Timer
User may enter an interval in increments of 10 seconds. The modem will ping the destination at that interval. Enter
0 to disable this feature.
•
Fail Count
The modem will reset if the number of consecutive ping failures is equal to or greater than this entry and the
secondary address is being used. Otherwise the modem will switch from the first address to the secondary address
for the ping test.
Vanguard 3000 Series Multicarrier Cellular Data Modem & IP Router PN 001-7300-100 Rev. B