The version number and kernel date of the updated firmware appear in the Current Firmware Information section
of the page.
Repeat the above procedure as many times (1 to 6) as necessary to upgrade the Vanguard 3000 to the current version
(5.1.2A).
When the Vanguard 3000 is at the current version, go through the pages of the Vanguard Web Interface to verify
settings. In the DeviceOutlook™ tab of the Diagnostics page, make sure the DeviceOutlook Client shows the current
DeviceOutlook Client version and that the Port is set to 20510. Make sure the Domain Name for the DeviceOutlook
Server is ota.calamp-ts.com and Port selected is 20511, and likewise for the DeviceOutlook Maintenance Server, make
sure the domain name is ota.calamp-ts.com and Port selected is 20511. See the following figure.
TO PERFORM A FULL FIRMWARE INSTALL
If a Vanguard will not complete boot up initialization.
If a Vanguard 3000 is reset in the middle of an upgrade, it may fail to come up completely (the LEDs display as all amber
or all green and the unit does not proceed to normal functioning). In this case, a full firmware install using the serial
port is required.
Requirements
The full firmware install procedure requires the following::
•
PC or notebook computer with a serial communications program, an available Ethernet LAN port, and an available
serial port.