3.7.2
INTERNAL SERIAL
The Internal Serial page is used to configure the internal RS232 Serial Port parameters and Packet Assembler and
Disassembler (PAD) functionality. The PAD feature forwards requests that come in on a specific port to the internal
serial port. For units with Dual Serial ports, the Internal Serial Page configures the second (back of the unit above the
SIM card) RS-232 port.
Figure 43 Serial — Internal Serial
Serial Port Configuration
•
Baud Rate
Sets the baud rate of the serial port. Settings may range from 300 to 115,200 bits per second. The default baud rate
is 115,200 bps.
PAD Settings
•
Remote IP Address
Sets the IP address of the device using the PAD functionality.
•
Remote Port
Sets the port number used by the remote device to accept requests from the Vanguard 3000.
•
Local Port
Sets the port number used by the Vanguard to accept requests from the remote device.
Vanguard 3000 Series Multicarrier Cellular Data Modem & IP Router PN 001-7300-100 Rev. B
| Page 67