ANOMALY
POSSIBLE CAUSES
SOLUTIONS
Pellets are not being fed into the
combustion chamber.
The pellet hopper is empty
Fill the hopper with pellets.
Sawdust has blocked the feed screw
Empty the hopper and remove the
sawdust from the feed screw by
hand.
Faulty gear motor
Replace the gear motor.
Faulty electronic board
Replace the circuit board.
The fire goes out or the appliance
stops automatically.
The pellet hopper is empty
Fill the hopper with pellets.
The pellets are not fed
See the previous anomaly.
The pellet temperature safety probe
has been triggered
Let the product cool down, restore
the thermostat until the problem is
resolved and switch the product
back on. If the problem persists
contact Technical Assistance.
The door is not closed properly or the
gaskets are worn
Close the door and replace the
gaskets with original ones.
Unsuitable pellets
Change the type of pellets with
those recommended by the
manufacturer.
Low pellet supply
Have the fuel flow checked following
the booklet instructions.
The combustion chamber is dirty
Clean the combustion chamber,
following the booklet instructions.
Clogged outlet
Clean the smoke duct.
Faulty smoke extraction motor
Check the motor and replace it, if
necessary.
Pressure switch faulty or defective
Replace the pressure switch.
The product works for a few minutes
and then switches off.
Start-up phase is not completed
Repeat start-up.
Temporary power cut
Wait for the automatic restart.
Clogged smoke duct
Clean the smoke duct.
Faulty or malfunctioning temperature
probes
Check and replace the probes.
Faulty spark plug
Check the spark plug and replace it,
if necessary.
Pellets accumulate in the brazier, the
glass of the door gets dirty and the
flame is weak.
Insufficient combustion air.
Clean the brazier and check that
all the holes are clear. Perform a
general cleaning of the combustion
chamber and the smoke duct.
Check that the air inlet is not
obstructed.
Damp or unsuitable pellets.
Change the type of pellets.
Faulty smoke evacuation motor.
Check the motor and replace it, if
necessary.
The smoke evacuation motor does
not work.
No electrical supply to the stove.
Check the mains voltage and the
protection fuse.
The motor is faulty.
Check the motor and capacitor and
replace them, if necessary.
Defective motherboard.
Replace the electronic board.
Control panel broken.
Replace the control panel.
Summary of Contents for aquos 15
Page 2: ......
Page 10: ...10 AQUOS IDRON IT Fig 4 Esempio di installazione prodotto a pellet ...
Page 13: ...13 AQUOS IDRON IT 4 DISEGNI E CARATTERISTICHE TECNICHE 4 1 DIMENSIONI Fig 7 Dimensioni ...
Page 29: ...29 AQUOS IDRON IT Fig 22 Configurazione 2 Fig 23 Configurazione 3 ...
Page 48: ...48 AQUOS IDRON IT 14 3 DICHIARAZIONE DI CONFORMITÀ Fig 33 Dichiarazione di conformità ...
Page 56: ...56 AQUOS IDRON EN Fig 4 Pellet stove installation example ...
Page 59: ...59 AQUOS IDRON EN 4 TECHNICAL DRAWINGS AND CHARACTERISTICS 4 1 DIMENSIONS Fig 7 Dimensions ...
Page 74: ...74 AQUOS IDRON EN Fig 22 Configuration 2 Fig 23 Configuration 3 ...
Page 93: ...93 AQUOS IDRON EN 14 3 DECLARATION OF CONFORMITY Fig 33 Declaration of Conformity ...
Page 101: ...101 AQUOS IDRON FR Fig 2 Exemple d installation d un produit à pellets ...
Page 104: ...104 AQUOS IDRON FR 4 DESSINS ET CARACTERISTIQUES TECHNIQUES 4 1 DIMENSIONS Fig 4 Dimensions ...
Page 120: ...120 AQUOS IDRON FR Fig 18 Configuration 2 Fig 19 Configuration 3 ...
Page 139: ...139 AQUOS IDRON FR 14 3 DÉCLARATION DE CONFORMITÉ Fig 29 Déclaration de conformité ...
Page 147: ...147 AQUOS IDRON ES Fig 4 Ejemplo de instalació del producto con pellet ...
Page 150: ...150 AQUOS IDRON ES 4 PLANOS Y CARACTERÍSTICAS TÉCNICAS 4 1 DIMENSIONES Fig 7 Dimensiones ...
Page 184: ...184 AQUOS IDRON ES 14 3 DECLARACIÓN DE CONFORMEDAD Fig 33 Declaración de conformedad ...
Page 193: ...193 AQUOS IDRON NL Fig 4 Installatievoorbeeld pelletkachel ...
Page 196: ...196 AQUOS IDRON NL 4 TEKENINGEN EN TECHNISCHE KENMERKEN 4 1 AFMETINGEN Fig 7 Afmetingen ...
Page 212: ...212 AQUOS IDRON NL Fig 22 Configuratie 2 Fig 23 Configuratie 3 ...
Page 231: ...231 AQUOS IDRON NL 14 3 CONFORMITEITSVERKLARING Fig 33 Conformiteitsverklaring ...