PortTrafficCongestion
Use PortTrafficCongestion to manage traffic congestion at switch ports. You can program the values for the minimum
and maximum threshold (in number of cells) for a specified priority queue. If the number of cells received by the switch
on the specified priority queue for a port exceeds the maximum threshold, the switch discards the cell.
2
p›F
You program values for minimum and maximum threshold by entering index
numbers that correspond to cell numbers. Use MinMaxTableIndex to see the
correspondance between index numbers and cell numbers.
Operators
modify, show
Parameters
Parameter
Description
Value/Field Size
Default
[PortNumber]
Port number on the switch.
1A1 to 8B4 or All
All
[QueueNumber]
Priority queue.
1-5
No default
[MinIndexNumber]
Index number for minimum cell threshold value.
Enter
show minmaxtable
to view possible values.
0-15
No default
[MaxIndexNumber]
Index number for maximum cell threshold value.
Enter
show minmaxtable
to view possible values.
0-15
No default
Output Parameter
Description
[Port ID]
Port number on the switch.
[QueueId]
Priority queue. (Same as the [QueueNumber] input parameter.)
[ServiceClass]
Service category. Possible values are: CBR, RTVBR, NRTVBR, ABR, and UBR.
[MinIndex]
Index number for minimum cell threshold value. (Same as the [MinIndexNumber] input
parameter.)
Summary of Contents for SmartSwitch 6500
Page 4: ...iv SmartSwitch 6500 Reference Manual...
Page 10: ...x SmartSwitch 6500 Reference Manual List of Tables...
Page 23: ...SmartSwitch 6500 Reference Manual 1 13 Introduction update Firmware...
Page 24: ...1 14 SmartSwitch 6500 Reference Manual Introduction...
Page 332: ...3 8 SmartSwitch 6500 Reference Manual Boot Load Commands...
Page 344: ...A 12 SmartSwitch 6500 Reference Manual Acronyms...
Page 348: ...B 4 SmartSwitch 6500 Reference Manual Event Alarm Messages...