Chassis Configuration Screen
DLEHF-MA User’s Guide
5-15
Figure 5-8
Chassis Configuration Screen
The following briefly explains each Chassis Configuration screen field:
MAC Address (Read-Only)
Displays the physical address of the chassis.
Chassis IP Address (Modifiable)
This field allows the IP address to be set for the DLM6C-AA chassis. If an IP
address is assigned to the DLM6C-AA chassis all the interface modules
installed in the chassis can be managed via this IP address, eliminating the
need to assign an IP address to each interface module. To set the IP
address, refer to Section 5.7.1.
Subnet Mask (Modifiable)
Displays the subnet mask for the chassis. A subnet mask “masks out” the
network bits of the IP address by setting the bits in the mask to 1 when the
network treats the corresponding bits in the IP address as part of the
network or subnetwork address, or to 0 if the corresponding bit identifies
Some firmware versions do not support the changing of the
chassis subnet mask from the default value. Refer to the
Release Notes to ensure that the Subnet Mask field is
modifiable.
MS 700 LOCAL MANAGEMENT
Chassis Configuration
236215
MAC Address:
Chassis IP Address:
Subnet Mask:
Chassis Date:
Chassis Time:
Screen Refresh Time:
Screen Lockout Time:
Chassis Uptime XX D XX H XX M
Operational Mode: [802.1D SWITCHING]
00-00-ID-00-00-00
000.000.000.000
000.000.000.000
Event Message Line
RETURN
SAVE
12/11/97
14:23:00
30 sec.
15 min.
EXIT