Chapter 5: Local Management
5-48
DLEHF-MA User’s Guide
2.
Enter a number from 1 to 30.
3.
Press ENTER to set the lockout time in the input field.
4.
Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is within the 1 to 30 minutes range, the Event Message
Line at the top of the screen displays “SAVED OK”. If the entry is not
valid, Local Management does not alter the current setting, but it does
refresh the Screen Lockout Time field with the previous value.
5.15.9
Setting the Operational Mode
To set the Operational Mode, proceed as follows:
1.
Use arrow keys to highlight the Operational Mode field.
2.
Press the SPACE bar to step to the appropriate operation mode,
(802.1D SWITCHING, 802.1Q SWITCHING.
3.
Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER. The warning screen shown back in
Figure 5 displays.
4.
Use the arrow keys to highlight the YES command and press ENTER.
The changes are saved and the module reboots.
!
Before setting the operational mode, ensure that the items
contained in this caution are fully understood.
The Management Mode of the module will automatically be set
to STAND ALONE. The Management Mode field will no longer
display on the General Configuration screen, and the module
will no longer support Chassis configuration and Module
selection screens.
The module has been assigned SNMP community names from
the module SNMP Community Names screen. In Standalone
management mode, the module does not use the community
names of the DLM6C-AA chassis.