![Cabletron Systems DLM6C-AA User Manual Download Page 178](http://html.mh-extra.com/html/cabletron-systems/dlm6c-aa/dlm6c-aa_user-manual_479939178.webp)
Appendix B: DELTX-UI, DELFX-UI and DELF3-UI Specifications
B-2
DLEHF-MA User’s Guide
B.2
DELFX-UI
The DELFX-UI shown in Figure B-2 uses an SC style connector that
supports multimode fiber optic cabling. Specifications for the DELFX-UI
are listed below.
Figure B-2
DELFX-UI
Table B-1
Transmitter Power
Cable Type
Worst Case Budget
Typical Budget
50/125 µm fiber
6.0 dB
9.0 dB
62.5/125 µm fiber
9.0 dB
12.0 dB
100/140 µm fiber
15.0 dB
18.0 dB
The transmitter power levels and receive sensitivity levels listed
are peak power levels after optical overshoot. A peak power
meter must be used to correctly compare the values given
above to those measured on any particular port. If power levels
are being measured with an average power meter, add 3 dB to
the measurement to compare the measured values to the
values listed above.
DELFX-UI
2
1
236257