7
Tools and materials
#6
Make sure that there are all tools and materials necessary
for installation (fig.6). Also check that they are in compliance
with Standards and in perfect working order.
Use suitable individual protection devices I.P.D. (gog-
gles, gloves, etc)
The length and type of connection cables depend on
the accessories installed (see “Electric connections”
paragraph).
The fixing devices for the gear motor are not supplied
as they depend on the features of the materials used
for the pillars and the leaves.
Choice of installation measurements - 1
Fig.6
Fig.7
Fig. 7 represents a view from above of the automation, indicating
the most important measurements for installation.
R indicates the hole in bracket BTY.1 onto which the gear mo-
tor is fixed and corresponds to the rotation axes of the gear
motor. It is necessary to calculate the correct positioning as
indicated below.
M: is a measurement on the gate and represents the distance
between the gate rotation axis and gear motor fixing surface
S: a distance that can be adjusted by means of the supplied
bracket BTY.1.
Y
: is given by the sum of M+S.
X
: depends on the opening angle requested and by the value
of the Y measurement.
IMPORTANT: The values of the X and Y measure-
ments must be as similar as possible (max difference
50 mm).
Values that are too different to each other do not allow regular
movement of the leaves and could cause malfunctioning.
Detect the value of the measurement M precisely and state it
in every box in column M
in Table 1.
Calculate all values possible of the Y measurement, adding the
value M
to the various values of the column S, completing all
boxes in column Y of table 1.
Tab. 1
S + M = Y
40 mm
......... mm
......... mm
97 mm
......... mm
......... mm
117 mm
......... mm
......... mm
121 mm
......... mm
......... mm
135 mm
......... mm
......... mm
155 mm
......... mm
......... mm
Establish the opening angle of the leaf:
- Take the leaf into the completely open position.
- If the angle of opening exceeds 90° find the appropriate angle
using, if necessary, the goniometer printed on the last page of
this manual.
Below find three tables, each referring to one of the opening an-
gles possible, up to 90°, from 90° to 100°, from 100° to 110°.
Up to 90°
from 90° to 100°
from 100° to 110°
Y
X
Y
X
Y
X
100 mm 150 mm
100 mm 140 mm
100 mm 140 mm
110 mm 150 mm
110 mm 140 mm
110 mm 130 mm
120 mm 150 mm
120 mm 140 mm
120 mm 130 mm
130 mm 140 mm
130 mm 130 mm
140 mm 140 mm
140 mm 120 mm
150 mm 130 mm
150 mm 120 mm
160 mm 120 mm
170 mm 120 mm
recommended
mesaurement
Depending on the values calculated in the Y column of Table 1,
select the pairs of measurements Y and X as similar as possible
in the table with the requested opening angle.
Make note of the measurement S corresponding to measure-
ment Y thus obtained. This value is indispensable for the correct
regulation of the bracket BTY.1, described in the “Fixing the
gear motor brackets BTY.1” paragraph.
Summary of Contents for BEAUTY