background image

7

Tools and materials

#6

  Make sure that there are all tools and materials necessary 

for installation (fig.6). Also check that they are in compliance 
with Standards and in perfect working order.

Use suitable individual protection devices I.P.D. (gog-
gles, gloves, etc)

The length and type of connection cables depend on 
the accessories installed (see “Electric connections” 
paragraph).
The fixing devices for the gear motor are not supplied 
as they depend on the features of the materials used 
for the pillars and the leaves.

Choice of installation measurements - 1

Fig.6

Fig.7

Fig. 7 represents a view from above of the automation, indicating 
the most important measurements for installation.

R indicates the hole in bracket BTY.1 onto which the gear mo-
tor is fixed and corresponds to the rotation axes of the gear 
motor. It is necessary to calculate the correct positioning as 
indicated below.

M: is a measurement on the gate and represents the distance 
between the gate rotation axis and gear motor fixing surface
S: a distance that can be adjusted by means of the supplied 
bracket BTY.1.

Y

: is given by the sum of M+S.

X

: depends on the opening angle requested and by the value 

of the Y measurement.

IMPORTANT: The values of the X and Y measure-
ments must be as similar as possible (max difference 
50 mm). 

Values that are too different to each other do not allow regular 
movement of the leaves and could cause malfunctioning.
Detect the value of the measurement M precisely and state it 
in every box in column M

 

in Table 1.

Calculate all values possible of the Y measurement, adding the 
value M

 

to the various values of the column S, completing all 

boxes in column Y of table 1.

Tab. 1
       S         +        M      =       Y

40 mm

......... mm

......... mm

97 mm

......... mm

......... mm

117 mm

......... mm

......... mm

121 mm

......... mm

......... mm

135 mm

......... mm

......... mm

155 mm

......... mm

......... mm

Establish the opening angle of the leaf:
- Take the leaf into the completely open position.
- If the angle of opening exceeds 90° find the appropriate angle 
using, if necessary, the goniometer printed on the last page of 
this manual.
Below find three tables, each referring to one of the opening an-
gles possible, up to 90°, from 90° to 100°, from 100° to 110°.

Up to 90°

from 90° to 100°

from 100° to 110°

Y

X

Y

X

Y

X

100 mm 150 mm

100 mm 140 mm

100 mm 140 mm

110 mm 150 mm

110 mm 140 mm

110 mm 130 mm

120 mm 150 mm

120 mm 140 mm

120 mm 130 mm

130 mm 140 mm

130 mm 130 mm

140 mm 140 mm

140 mm 120 mm

150 mm 130 mm

150 mm 120 mm

160 mm 120 mm
170 mm 120 mm

recommended  
mesaurement

Depending on the values calculated in the Y column of Table 1, 
select the pairs of measurements Y and X as similar as possible 
in the table with the requested opening angle.

Make note of the measurement S corresponding to measure-
ment Y thus obtained. This value is indispensable for the correct 
regulation of the bracket BTY.1, described in the “Fixing the 
gear motor brackets BTY.1” paragraph.

Summary of Contents for BEAUTY

Page 1: ...L8543185 ENG 03 2016 rev 0 Complete kit for the automation of swinging gates Instructions and Recommendations for installation and use MADE IN ITALY BEAUTY...

Page 2: ...Sld 20 Resetting the control unit Res 20 Memorising new transmitters RADI PP 21 Memorising pedestrian function RADI Ped 21 Deleting transmitters RADI CLR 22 Complete deletion of the receiver memory R...

Page 3: ...ve received instructions for use by people in charge of their security Check that the temperature range marked on the drive is suitable for the location The drive cannot be used with a driven part inc...

Page 4: ...or wall installation 1 transmitter TX 1 receiver RX 8 BTY 3 Release keys for manual manoeuvre 9 Plugs and screws for fixing the accessories flashing light key selector photocells 10 F BY Flashing ligh...

Page 5: ...epend on the state of the gate structure Check that there is enough space for installation of the operator in safe and comfortable conditions Technical Data dimensions and limits of use TECHNICAL DATA...

Page 6: ...ce with the wiring rules 2 It is recommended not to exceed 15 m in length If it is indispensable to exceed this limit increase the section of the cable 3 As the receiver photocell labelled RX requires...

Page 7: ...too different to each other do not allow regular movement of the leaves and could cause malfunctioning Detect the value of the measurement M precisely and state it in every box in column M in Table 1...

Page 8: ...ues for positioning of the brackets BTY 1 Adjustable brackets BTY 1 Using the adjustable brackets BTY 1 it is possible to install the BEAUTY gear reducer with different installation measurements witho...

Page 9: ...de the gear motor BTY 1 It is important to consider the correspondence between the height established and the presence of gate support structures Fig 9 Fig 10 Fig 11 C F V D R Fig 12 2 The electrical...

Page 10: ...is perfectly horizontal and then mark the two points for drilling the leaf fig 17 V R2 R1 Also in this case the fixing devices will be selected on the basis of the material with which the leaf is mad...

Page 11: ...ated in the Electric connec tions paragraph Fig 21 P A Fixing the CP BTY control unit With reference to the Electric connections chapter Fig 5 select the most suitable position for fixing the control...

Page 12: ...screws are supplied for fixing the flashing light Make two holes with diameter of 6 mm Insert the cable and fix the base using the plugs and screws ANT SHIELD Connections ANT SHIELD Connect the 24V fl...

Page 13: ...ge of the cables Four 6 mm plugs and relative screws are supplied for fixing the photocells Make two holes with diam eter of 6 mm in a way that the hole in proximity of the terminal board corresponds...

Page 14: ...selector Two 6 mm plugs and relative screws are supplied for fixing the selector base to the wall V Using the support as a reference mark and make two holes with diameter of 6 mm in a way that the lo...

Page 15: ...ansmitter for the long distance commands for BYOU automations Functioning The transmitter has three buttons through which it is possible to command the various functions of the automation configurable...

Page 16: ...ED 24 Vdc flashing light connection output MOT1 ORANGE Motor 1 connection output respect red and blue ref C MOT2 ORANGE Motor 2 connection output respect red and blue ref C SHIELD ANT BLUE Connection...

Page 17: ...essage 5 The self regulation phase starts the display shows PRG The control unit commands different open ing and closing manoeuvres at various speeds At the end of the manoeuvre the display shows OK P...

Page 18: ...re time TCA The automatic closure function allows to set a time which on expiry if the leaf is in the open position the control unit autono mously commands a closure manoeuvre With this function activ...

Page 19: ...on of commands is performed cyclically OPEN STOP CLOSE STOP OPEN and so on The sequence can be modified by eliminating the intermediate STOP commands OPEN CLOSE OPEN and so on 1 Press the PGM button t...

Page 20: ...lation The display shows the current value of the Sld parameter Use the 5 key to select one of these values ON reduced speeds OFF standard speed default on off 3 Confirm the desired value using the PG...

Page 21: ...ramming menu press the PGM and 5 buttons at the same time Press the PGM and 5 buttons twice at the same time to go back to the main Radi menu To exit programming remove the power supply or wait for 60...

Page 22: ...PP Press 5 three times to display the RTR sub menu rtr 3 Press the PGM button to enter the RTR function Press and hold PGM the RTR message starts to flash quickly 4 When the RTR message switches off r...

Page 23: ...ry power supply cable with a mains con nection that is in compliance with the Standards in force and the type of installation COMMISSIONING Commissioning of the automation can only be performed if all...

Page 24: ...re present release the motor and check for the presence of friction points Perform a new self learning Increase the value of the PMOT parameter The door does not close STOP input active Obstacle betwe...

Page 25: ...st be followed regarding differentiated disposal and re cycling of the various components metals plastics electric cables etc It is advised to contact a BYOU specialised technician or a specialised co...

Page 26: ...2006 42 CE OF EH EUROPEAN PARLIAMENT AND COUNCIL 17 May 2006 in relation to ma chinery amending Directive 95 16 CE in relation to the requisites for partly completed machinerys per the following harm...

Page 27: ......

Page 28: ...BYOU un marchio di Automatismi Beninc SpA via Capitello 45 36066 Sandrigo VI ITALY Tel 39 0444 1510294 Fax 39 0444 759728 info byouweb com www byouweb com...

Reviews: