background image

3

General recommendations

 

WARNING: Important safety instructions. Follow all 

instructions since incorrect installation can lead to 
severe injury.

f this is the first time you realise an automation for swing 
gates with Beauty, we recommend that you read this manual 
carefully as it contains important advice and information for 
the realisation of the plant in safe conditions.
Keep the various components on hand to gain confidence 
with them while reading this manual.
Keep this manual for future use.
BEAUTY is realised in a way to allow easy installation and 
configuration of the system, however, some phases require 
the presence of qualified staff.
When reading this manual pay particular attention to these 
symbols:

Authorised technician. 
Indicates the phases to be performed in the pres-
ence of mains voltage. The presence of qualified 
staff is required (electrician or authorised installer), 
in complete respect with the Safety Standards in 
force.
Attention! 
Potentially dangerous operations. Scrupulously 
respect the indications given.
Useful indication.
Suggestions and recommendations for simplifying 
and/or improving the installation operations.

The automation of a door cannot be considered the only 
device for protection against intrusion.
Do not use any of the components in unsuitable environ-
ments (salty, acid or potentially explosive atmosphere)

All operations that require the protection shells of the 
devices opened, must take place without mains power 
supply.

This item is not intended to be used by people (including 
children) with reduced physical, sensorial or mental abili-
ties, or without adequate knowledge of the product, unless 
they are under the supervision of eligible persons or they 
have received instructions for use by people in charge of 
their security.
Check that the temperature range marked on the drive is 
suitable for the location.
The drive cannot be used with a driven part incorporating a 
wicket door (unless the drive cannot be operated with the 
wicket door open).
Ensure that entrapment between the driven part and the 
surrounding fixed parts due to the opening movement of 
the driven part is avoided.
After installation, ensure that the mechanism is properly 
adjusted and that the protection system and any manual 
release function correctly.

DESTINATION OF USE

This product is destined exclusively for the opening and 
closure of swing doors for the passage of vehicles, charac-
terised by dimensional limits and weight as indicated in this 
manual in the “Limits of use” paragraph. 

No other use is allowed. 

BYOU is not liable for uses that are not in compliance with 
those indicated in these instructions.

The kit is made up from two electromechanical operators 
with 24V direct current motor, which allows movement of 
the leaves via a worm screw.
The control unit commands the movement of the two motors 
and the functioning of the various accessories.
The supplied accessories are:
- 1 P.BY pair of photocells: they interrupt the movement of 
the leaf if there are obstacles present.
- 1 F.BY flashing light: flashing light that indicates that the 
door is moving. 
- 1 K.BY key selector switch: installed externally, allows the 
opening and closure by means of a customised key.
- 2 BY radio transmitters: remote control for opening/clos-
ing the door.
Other accessories available as options:
- CB.BY emergency battery kit: in case of a power cut, it 
allows the functioning of the leaf by batteries and relative 
battery charger installed inside the operator.
- C.BY pair of small columns for additional pair of photo-
cells F.BY: to be installed within the property (see para-
graph C.BY).

Product description

Summary of Contents for BEAUTY

Page 1: ...L8543185 ENG 03 2016 rev 0 Complete kit for the automation of swinging gates Instructions and Recommendations for installation and use MADE IN ITALY BEAUTY...

Page 2: ...Sld 20 Resetting the control unit Res 20 Memorising new transmitters RADI PP 21 Memorising pedestrian function RADI Ped 21 Deleting transmitters RADI CLR 22 Complete deletion of the receiver memory R...

Page 3: ...ve received instructions for use by people in charge of their security Check that the temperature range marked on the drive is suitable for the location The drive cannot be used with a driven part inc...

Page 4: ...or wall installation 1 transmitter TX 1 receiver RX 8 BTY 3 Release keys for manual manoeuvre 9 Plugs and screws for fixing the accessories flashing light key selector photocells 10 F BY Flashing ligh...

Page 5: ...epend on the state of the gate structure Check that there is enough space for installation of the operator in safe and comfortable conditions Technical Data dimensions and limits of use TECHNICAL DATA...

Page 6: ...ce with the wiring rules 2 It is recommended not to exceed 15 m in length If it is indispensable to exceed this limit increase the section of the cable 3 As the receiver photocell labelled RX requires...

Page 7: ...too different to each other do not allow regular movement of the leaves and could cause malfunctioning Detect the value of the measurement M precisely and state it in every box in column M in Table 1...

Page 8: ...ues for positioning of the brackets BTY 1 Adjustable brackets BTY 1 Using the adjustable brackets BTY 1 it is possible to install the BEAUTY gear reducer with different installation measurements witho...

Page 9: ...de the gear motor BTY 1 It is important to consider the correspondence between the height established and the presence of gate support structures Fig 9 Fig 10 Fig 11 C F V D R Fig 12 2 The electrical...

Page 10: ...is perfectly horizontal and then mark the two points for drilling the leaf fig 17 V R2 R1 Also in this case the fixing devices will be selected on the basis of the material with which the leaf is mad...

Page 11: ...ated in the Electric connec tions paragraph Fig 21 P A Fixing the CP BTY control unit With reference to the Electric connections chapter Fig 5 select the most suitable position for fixing the control...

Page 12: ...screws are supplied for fixing the flashing light Make two holes with diameter of 6 mm Insert the cable and fix the base using the plugs and screws ANT SHIELD Connections ANT SHIELD Connect the 24V fl...

Page 13: ...ge of the cables Four 6 mm plugs and relative screws are supplied for fixing the photocells Make two holes with diam eter of 6 mm in a way that the hole in proximity of the terminal board corresponds...

Page 14: ...selector Two 6 mm plugs and relative screws are supplied for fixing the selector base to the wall V Using the support as a reference mark and make two holes with diameter of 6 mm in a way that the lo...

Page 15: ...ansmitter for the long distance commands for BYOU automations Functioning The transmitter has three buttons through which it is possible to command the various functions of the automation configurable...

Page 16: ...ED 24 Vdc flashing light connection output MOT1 ORANGE Motor 1 connection output respect red and blue ref C MOT2 ORANGE Motor 2 connection output respect red and blue ref C SHIELD ANT BLUE Connection...

Page 17: ...essage 5 The self regulation phase starts the display shows PRG The control unit commands different open ing and closing manoeuvres at various speeds At the end of the manoeuvre the display shows OK P...

Page 18: ...re time TCA The automatic closure function allows to set a time which on expiry if the leaf is in the open position the control unit autono mously commands a closure manoeuvre With this function activ...

Page 19: ...on of commands is performed cyclically OPEN STOP CLOSE STOP OPEN and so on The sequence can be modified by eliminating the intermediate STOP commands OPEN CLOSE OPEN and so on 1 Press the PGM button t...

Page 20: ...lation The display shows the current value of the Sld parameter Use the 5 key to select one of these values ON reduced speeds OFF standard speed default on off 3 Confirm the desired value using the PG...

Page 21: ...ramming menu press the PGM and 5 buttons at the same time Press the PGM and 5 buttons twice at the same time to go back to the main Radi menu To exit programming remove the power supply or wait for 60...

Page 22: ...PP Press 5 three times to display the RTR sub menu rtr 3 Press the PGM button to enter the RTR function Press and hold PGM the RTR message starts to flash quickly 4 When the RTR message switches off r...

Page 23: ...ry power supply cable with a mains con nection that is in compliance with the Standards in force and the type of installation COMMISSIONING Commissioning of the automation can only be performed if all...

Page 24: ...re present release the motor and check for the presence of friction points Perform a new self learning Increase the value of the PMOT parameter The door does not close STOP input active Obstacle betwe...

Page 25: ...st be followed regarding differentiated disposal and re cycling of the various components metals plastics electric cables etc It is advised to contact a BYOU specialised technician or a specialised co...

Page 26: ...2006 42 CE OF EH EUROPEAN PARLIAMENT AND COUNCIL 17 May 2006 in relation to ma chinery amending Directive 95 16 CE in relation to the requisites for partly completed machinerys per the following harm...

Page 27: ......

Page 28: ...BYOU un marchio di Automatismi Beninc SpA via Capitello 45 36066 Sandrigo VI ITALY Tel 39 0444 1510294 Fax 39 0444 759728 info byouweb com www byouweb com...