Installation of the flashing light F.BY
Description
Flashing light signalling that the gate is in movement for auto-
matic doors and gates. It has a built-in aerial for the reception
of radio transmitters.
Installation
Choose the position of the flashing light so that it is proximity
of the gate and easily visible.
The flashing light can be fixed onto a horizontal or vertical
surface. In the case of vertical installation the protection rating
is reduced to X4.
A
Loosen the two screws V and then remove the transparent
cover.
ANT
SHIELD
ANT
SHIELD
ANT
SHIELD
V
V
H
Remove the electronic circuit, pulling the two plastic tabs H
outwards, thus releasing the board.
ANT
SHIELD
Two 6 mm plugs and relative screws are supplied for fixing the
flashing light.
Make two holes with diameter of 6 mm.
Insert the cable and fix the base using the plugs and screws.
ANT
SHIELD
Connections
ANT
SHIELD
Connect the 24V flashing light output of the control unit to the
terminal board M1 (see main connection layout).
Connect the aerial cable RG58 to the terminal board M2 (if
requested). The external shield must be connected to the
B
C
Trace the drilling points using the base as a reference. The
central hole must correspond to the passage of the cables.
ANT
SHIELD
SHIELD clamp. The signal cable must be connected to the
ANT clamp.
Put the board back into the relevant sear and then close the
flashing light.
TECHNICAL DATA
Flashing light F.BY
Power supply
24Vac Flashing light output
of the BYOU control units
Bulb
E14/24Vac/dc
Absorption
600 mA
Functioning temperature
-20°C / +70°C
Protection rating
IP44
Dimensions
145x65x128 (mm)