The va cuum pump runs very hot

(the oil sump tem pe ra ture shall not ex ceed
100 °C)

Insuf fi cient  air  ven ti la tion

Make sure that the co o ling of the va cuum
pump is not im pe ded by dust/dirt

Clean the fan co wlings, fan wheels, ven ti la -
tion screens and co o ling fins 

Install the va cuum pump in a nar row space
only  if  suf fi cient  ven ti la tion  is  en su red

On a va cuum pump with oil-co o ler: 

 Clean the in ter me diate spa ces of the fin ned
tube

Ambient  tem pe ra ture  too  high

Observe  the  per mit ted  am bient  tem pe ra tu res

Tem pe ra ture of the in let gas too high

Observe  the  per mit ted  tem pe ra tu res  for  the
in let  gas

The ex haust fil ter(l) is par tial ly clog ged

Re place the ex haust fil ters (l)

The oil fil ter is par tial ly clog ged

(the oil flows through the by pass only, the oil
does not get fil te red any more)

Re place the oil fil ter (d)

(see  “Main te nance”)

Not enough oil in the re ser voir

Top up oil

Oil burnt from over hea ting

Flush the va cuum pump

Re place the oil fil ter (d)

Re place the ex haust fil ters (l)

Fill in new oil

(see  “Main te nance”)

In case the oil life is too short: use oil with
bet ter heat re sis tance (see “Oil”) or re tro fit
co o ling

Mains  fre quen cy  or  vol tage  out side  to le rance
range

Pro vide a more stable po wer sup ply

In case a mesh screen (h) is ins tal led on the
suc tion  connec tion  (a):

The mesh screen (h) on the suc tion connec -
tion (a) is par tial ly clog ged

Clean the mesh screen (h)

If clea ning is re qui red too fre quen tly ins tall a
fil ter  ups tream

In case an in let air fil ter is ins tal led on the suc -
tion connec tion (a):

 The fil ter on the suc tion connec tion (a) is
par tial ly  clog ged 

Clean or re place the fil ter

Par tial clog ging in the suc tion or dis charge
line

Re move the clog ging

Long suc tion, dis charge or pres sure line with -
too small dia me ter

Use  lar ger  dia me ter

The va cuum pump fu mes at the ex haust side
or ex pels oil dro plets through the ou tlet

The oil le vel drops

The ex haust fil ters (l) are not pro per ly sea ted

Check the pro per po si tion of the ex haust fil -
ters

(see  “Main te nance”)

The O-rings from the ex haust fil ters are mis -
sing or da ma ged

Add or re place the O-rings

(see  “Main te nance”)

The ex haust fil ters (1) show cracks

Re place the ex haust fil ters (l)

(see  “Main te nance”)

The ex haust fil ters (1) are clog ged with fo -
reign mat ter

NOTE

: The sa tu ra tion of the ex haust fil ters -

with oil is no fault and does not im pair the
func tion of the ex haust fil ters! Oil drop ping
down from the ex haust fil ters is re tur ned to
the oil circulation.

Re place the ex haust fil ters (l)

(see  “Main te nance”)

Troubleshooting

Page  17

Summary of Contents for R50160D

Page 1: ...Installation and Operating Instructions Vacuum pumps R 5 0160 D R 5 0202 D R 5 0250 D R 5 0302 D Ateliers Busch S A Zone industrielle 2906 Chevenez Switzerland 0870524627 040106 Modifications reserved ...

Page 2: ... Filling in Fresh Oil 11 Exhaust Filter 11 Check during operation 11 Assessment 12 Change of the exhaust filters 12 Removing the exhaust filters 12 Inserting the Exhaust Filters 12 Gas ballast 12 Inlet flange 12 Fan cover 12 Motor cover 12 Overhaul 13 Removal from Service 13 Temporary Removal from Service 13 Recommissioning 13 Dismantling and Disposal 13 Troubleshooting 14 Exploded view 19 Spare p...

Page 3: ...e mo tor shaft by means of a flexible coupling The rotor o 15 rotates in an also circular fixed cylinder 1 the cen treline of which is offset from the centreline of the rotor such that the rotor and the inner wall of the cylinder almost touch along a line Va nes n 22 sliding in slots in the rotor separate the space between the rotor and the cylinder into chambers At any time gas is sucked in and a...

Page 4: ...ons a heat exchanger wa ter oil can be mounted as a complementary cooling optional To suck condensable vapours a gas ballast valve optional can be ins talled in the cylinder cover at fan side To increase the capacity of va pours another gas ballast valve can be installed in the cylinder cover at the motor side The valve can open or close the gas ballast during the operation of the pump In order to...

Page 5: ...ginal packaging indoors dry dust free vibration free Conservation In case of adverse ambient conditions e g aggressive atmosphere fre quent temperature changes conserve the vacuum pump immediately In case of favourable ambient conditions conserve the vacuum pump if a storage of more than 3 months is scheduled During the factory tests the vacuum pump inside has been completely in contact with oil I...

Page 6: ...ensitive parts plastics wood cardboard paper electronics will touch the surface of the vacuum pump Make sure that the installation space or location is vented such that a sufficient cooling of the vacuum pump is warranted CAUTION During operation the surface of the vacuum pump may reach tem peratures of more than 70 C Risk of burns Make sure that the vacuum pump will not be touched inadverten tly ...

Page 7: ... that the drive of the vacuum pump will not be affected by electric or electromagnetic disturbance from the mains if neces sary seek advice from the Busch service In case of mobile installation Provide the electrical connection with grommets that serve as strain relief Heat exchanger water oil accessory It is possible to install a heat exchanger water oil accessory as a complementary cooling when ...

Page 8: ...except for oils based on poly a olefin are incompa tible with mineral oils and conservation oils Risk of foaming leading to destruction of the vacuum pump CAUTION Filling oil through the gas inlet a 260 will result in breakage of the vanes n 22 and destruction of the vacuum pump Oil may be filled through the oil fill port only k 88 CAUTION During operation the oil separator is filled with hot pres...

Page 9: ...way Make sure that the Installation Prerequisites see Installation Prerequisites and Commissioning are complied with and will re main complied with particularly that a sufficient cooling will be ensured Conveying Condensable Steams CAUTION Residual condensates dilute the oil deteriorate its lubricating proper ties and can cause a jam of the rotor Apply a suitable operating method to make sure that...

Page 10: ... on the vacuum pump Busch service Checking the oil Checking the level Make sure that the vacuum pump is shut down and locked against inadvertent start up Make sure that the oil has collected at the bottom of the oil sepa rator f 75 Read the level on the sight glass i 83 In case the level has dropped underneath the MIN marking Top up oil see Topping up Oil In case the level exceeds the MAX marking ...

Page 11: ...60 0202 D and 6 5 litres of flushing agent for the versions R 5 0250 0302 D from 50 percent oil and 50 percent paraffin or die sel fuel fuel oil Make sure that the oil drain plug j 95 is reinsert correctly Remove the oil fill plug k 88 Fill in the flushing agent Firmly reinsert the oil fill plug k 88 with its sealing seat 89 Close the suction line Run the vacuum pump for at least half an hour Drai...

Page 12: ...ry Release the spring elements 125 by unscrewing the screws 126 and remove them Remove the exhaust filters l 120 and the o rings 121 In the case of a R 5 0160 D or R 5 0202 D version The exhaust filters are two In the case of a R 5 0250 D or R 5 0302 D version The exhaust filters are three Inserting the Exhaust Filters CAUTION The non OEM spares market offers exhaust filters that are geome tricall...

Page 13: ...ent start up Remove the cover around the fan of the drive motor Slowly rotate the fan wheel by hand several revolutions in the intended direction of rotation see stuck on or cast arrow Mount the cover around the fan wheel of the drive motor If deposits could have gathered in the vacuum pump Flush the vacuum pump see Maintenance Observe the chapter Installation and Commissioning Dismantling and Dis...

Page 14: ...ss only the oil does not get filtered any more Replace the oil filter d see Maintenance In case a mesh screen h is installed on the suction connection a The mesh screen h on the suction connec tion a is partly clogged Clean the mesh screen h If cleaning is required too frequently install a filter upstream In case an inlet filter is installed on the suction connection a The filter on the suction co...

Page 15: ... level is too low Compare the trip level of the drive motor star ter overload protection with the data on the nameplate Correct if necessary In case of high ambient temperature Set the trip level of the drive motor starter overload protection 5 percent above the no minal drive motor current One of the fuses has blown Check the fuses The connection cable is too small or too long causing a voltage d...

Page 16: ...he wires against the connection diagram Tighten or replace loose connections The vacuum pump runs in the wrong direc tion Verification and rectification see Installation and Commissioning correct if necessary Standstill over several weeks or months Let the vacuum pump run warm with inlet closed Oil viscosity is too high for the ambient tem perature Use synthetic oil if necessary use oil of the nex...

Page 17: ...utside tolerance range Provide a more stable power supply In case a mesh screen h is installed on the suction connection a The mesh screen h on the suction connec tion a is partially clogged Clean the mesh screen h If cleaning is required too frequently install a filter upstream In case an inlet air filter is installed on the suc tion connection a The filter on the suction connection a is partiall...

Page 18: ...atery and coloured white The vacuum pump aspirated water or signifi cant amounts of humidity Flush the vacuum pump Replace the oil filter d Replace the exhaust filters l Flush the vacuum pump see Maintenance Modify the operational mode see Installation and Commissioning Opera ting Notes Conveying Condensable Vapours The oil is resinous and or sticky Improper oil type perhaps in confusion Flush the...

Page 19: ...Exploded view Exploded view Page 19 ...

Page 20: ...eal 1 0481 503 786 159 Discharge valve 2 0916 529 297 162 Seal 1 0481 503 785 185 Oil separator seal 1 0481 516 780 197 O ring 1 0486 516 620 206 Oil separator seal 1 0481 502 719 242 O ring 2 0486 000 587 253 O ring 1 0486 000 526 255 O ring 2 0486 000 531 261 Mesh screen 1 0534 000 041 Pos Part Qt R 5 0250 D R 5 0302 D 18 Sleeve 2 0472 000 008 22 Vanes 3 0722 516 729 30 Needle bearing 2 0473 507...

Page 21: ... cartridge 0945 000 143 0945 000 143 Replacement paper cartridge 0532 000 004 0532 000 004 Gas ballast side fan cover 0916 516 610 0916 516 610 Gas ballast with solenoid valve side fan cover 0916 518 385 0916 518 385 Silencer 0947 000 083 0947 000 083 Exhaust filters pressure gauge 0946 504 734 0946 504 734 Vacuum regulating unit connec tion G 11 2 0947 000 482 0947 000 482 Motor safety switch Adj...

Page 22: ...ic viscosity at 40 C mm2 s 30 68 110 95 94 103 Kinematic viscosity at 100 C mm2 s 5 8 5 11 5 9 5 14 Flashpoint C 225 235 260 255 264 265 Pourpoint C 15 15 15 30 15 48 Part no 1 l bottle 0831 000 086 0831 102 492 0831 000 060 0831 000 099 0831 133 403 0831 000 108 Part no 5 l canister 0831 000 087 0831 102 493 0831 000 059 0831 000 100 0831 540 557 0831 000 109 Note Ultimate pres sure application F...

Page 23: ...7 5 Nominal motor speed 50 60 Hz min 1 1500 1800 Sound level EN ISO 2151 50 60 Hz dB A 70 72 72 74 72 74 74 76 Water vapour tolerance max with gas ballast DIN 28426 hPa mbar 40 Water vapour capacity 50 60 Hz l h 2 5 2 8 4 4 6 4 5 5 5 5 8 Operating temperature 50 60 Hz C 64 66 71 78 80 81 82 85 Ambient temperature range C see Oil Ambient pressure Atmospheric pressure Oil capacity l 5 Weight approx ...

Page 24: ...Certain Voltage Limits so called Low Voltage 73 23 EEC Electromagnetic Compatibility 89 336 EEC have been designed and manufactured to the following specifications Standards Title of the standard Harmonised standards EN ISO 12100 1 EN ISO 12100 2 Safety of machinery Basic concepts general principles of design Part 1 and 2 EN 294 Safety of machinery Safety distance to prevent danger zones being rea...

Page 25: ... 1470 Italy Busch Italia S R L Via Ettore Majorana 16 20054 Nova Milanese Tel 0362 370 91 Fax 0362 370 999 Japan Busch Japan Ltd Akimoto Bldg 2 17 5 Ohgibashi Koto ku Tokyo 135 0011 Tel 03 3640 9971 Fax 03 3640 9972 Korea Busch Korea Ltd 392 1 Yangji Ri Yangji Myun Yongin City Kyunggi Do KOREA Tel 031 321 8114 Fax 031 321 4330 Malaysia Busch Malaysia Sdn Bhd 6 Jalan Taboh 33 22 Shah Alam Technolog...

Reviews: